Lantronix CWDM-M551LCR-B CWDM Series Quick Start Guide Rev B - Page 2

Connections, CWDM Connections, Troubleshooting

Page 2 highlights

CWDM-xxxxxCR-B Quick Start Guide 16-Channel CWDM Mux/Demux Front Panel (CWDM-M1631LCR-B) Handling Fiber Cables: Inspect the ends of all connectors for dust or imperfections. Keep the connectors' protective cover on when not in use. Use care in handling all fiber-optic connectors. Inspect fiber ends for signs of damage. Always clean and inspect fiber connectors before making a connection. Installing Fiber Cables: To install the fiber cables: 1. Remove the protective cover from the port. 2. Locate a 2-strand fiber cable with the appropriate male connectors installed on both ends. 3. Carefully insert the fiber cable into the CWDM and the device. Connections CWDM Mux/Demux right; CWDM Add/Drop Mux far right: CWDM Connections The figure below shows Lantronix CWDM Mux/Demux & Add/Drop Mux modules. In the figure, λ1 indicates Lambda 1 (for one particular wavelength). Troubleshooting: 1. Make sure the fiber connectors are clean; see the FOA.org termination cleaning webpage. 2. Make sure your model supports the feature or function attempted. 3. Verify the install process. 4. Troubleshoot connected network devices to point to the switch. 5. When calculating optical loss, ensure that the total loss, plus a safety factor (typically 3dB) does not exceed the optical power budget (the difference between the transmitter optical output power and the receiver's optical sensitivity). See the equipment manufacturers' documentation for transmitter optical output power and receiver optical sensitivity values. 6. See the FOA.org Testing & Troubleshooting Fiber Optic Systems webpage. 7. Record device information and Contact Tech Support. Contact Us: Lantronix Corporate Headquarters: 7535 Irvine Center Drive, Suite100, Irvine, CA 92618, USA. Toll Free: 800-526-8766; Phone: 949-453-3990; Fax: 949-453-3995. Technical Support Online. Sales Offices: www.lantronix.com/about/contact. 33793 Rev. B https://www.lantronix.com/ Page 2 of 2

  • 1
  • 2

CWDM-xxxxxCR-B Quick Start Guide
33793 Rev. B
Page 2 of 2
16-Channel CWDM Mux/Demux Front Panel (CWDM-M1631LCR-B)
Handling Fiber Cables
:
Inspect the ends of all connectors for dust or imperfections. Keep the connectors’ protective
cover on when not in use. Use care in handling all fiber-optic connectors. Inspect fiber ends for signs of damage. Always
clean and inspect fiber connectors before making a connection.
Installing Fiber Cables
:
To install the fiber cables:
1.
Remove the protective cover from the port.
2.
Locate a 2-strand
fiber cable with the appropriate male connectors installed on both ends.
3.
Carefully insert the fiber cable into the CWDM
and the device.
Connections
CWDM Mux/Demux right;
CWDM Add/Drop Mux far right
:
CWDM Connections
The figure below shows Lantronix CWDM Mux/Demux & Add/Drop Mux modules. In the figure,
λ1 indi
cates Lambda 1 (for
one particular wavelength).
Troubleshooting
:
1.
Make sure the fiber connectors are clean; see the
FOA.org
termination cleaning webpage.
2.
Make sure your model supports the feature or function attempted.
3.
Verify the install process.
4.
Troubleshoot
connected network devices to point to the switch.
5.
When calculating optical loss, ensure that the total loss, plus a safety
factor (typically 3dB) does not exceed the optical power budget (the difference between the transmitter optical output
power and the receiver’s optical sensitivity). See the equipment manufacturers’ documentation for transmitter optical
output power and receiver optical sensitivity values.
6.
See the
FOA.org Testing & Troubleshooting Fiber Optic Systems
webpage.
7.
Record device information and Contact Tech Support.