Lantronix EDS8PR EDS - Command Reference - Page 21

Configuration Using XML, EDS Command Reference, Group Name, Group Item, Value Name, Value Options - firmware

Page 21 highlights

Group Name cli Group Item Value Name login password enable level password quit connect line clock device diagnostics inactivity timeout time zone zone offset time set short name long name serial number firmware version log hours minutes seconds day of month month year output max length severity level 4: Configuration Using XML Value Options <None>, ... import/export import/export import import import import import import Additional Information Value is SECRET, hidden from user view. Value is SECRET, hidden from user view. Accepts text containing control characters, for example, <control> A represents control-A Default: L Default: 15 minutes Time zone name such as GMT. Time zone offset from GMT as [-]HH:MM disable, filesystem, line debug, information, notice, warning, error Read only. Read only. Default: disable Default: 50 Kbytes Default: debug EDS Command Reference 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221

4: Configuration Using XML
EDS Command Reference
21
cli
login password
Value is SECRET,
hidden from user
view.
enable level
password
Value is SECRET,
hidden from user
view.
quit connect line
Accepts text
containing control
characters, for
example,
&#60;control&#62;
A represents
control-A Default:
<control>L
inactivity timeout
&#60;None&#62;, ...
Default: 15
minutes
clock
time zone
zone
import/export
Time zone name
such as GMT.
offset
import/export
Time zone offset
from GMT as
[-]HH:MM
time set
hours
import
minutes
import
seconds
import
day of month
import
month
import
year
import
device
short name
long name
serial number
Read only.
firmware version
Read only.
diagnostics
log
output
disable, filesystem,
line <number>
Default: disable
max length
Default: 50 Kbytes
severity level
debug, information,
notice, warning, error
Default: debug
Group Name
Group Item
Value Name
Value Options
Additional
Information