Transition Networks EO2Pxx4052-111 Quick Start Guide Powering the EO2P The 90W Power supply 25148 is an option for powering the Local PSE unit, and is optional for use with the Remote PD Unit. The PWR LED blinks to indicate the presence of power to the EO2Pxx4052-111 (for indoor use only). 48 VDC IN Options: The two 48 VDC input options are the 4-Pin Mini DIN and the 2-Pin Terminal Block (right). Note: use the flat-topped grip to remove the power supply cable from the 48VDC IN 4-Pin Mini DIN connection. Local PSE (EO2PSE4052-111) Power Input Options: 1. A 4-Pin mini DIN with the designated AC to DC adapter OR 2. 2-Pin Terminal Block connectors for +48 VDC power source that must meet IEEE 802.3 af/at isolation requirements of 1500VAC or 2250 VDC. Note: this must be +48 VDC IN. Remote PD (EO2PD4052-111) Power Input Options: 1. A 4-Pin mini DIN with the designated AC to DC adapter OR 2. 2-Pin Terminal Block connectors for +48 VDC power source that must meet IEEE 802.3 af/at isolation requirements of 1500VAC or 2250 VDC. OR 3. PoE input power to the Remote Unit from the Local unit via the 2-wire cable. Grounding: An earth ground chassis stud is provided on the back panel. Note that bonding the earth ground to the chassis stud is required for circuit protection. Software Operation Web GUI Configuration: The Web GUI lets you access the Login page and subsequent configuration pages (2-Wire, IP, Ethernet, Device, Auto Power Reset, and Advanced) and Status (Power, SFP, and Remote Upgrade Status) pages. The default IP address is 192.168.0.1 (Local) and 192.168.0.2 (Remote). The default password is admin. We recommend you change your password immediately. See the User Guide for notes for installations with multiple pairs of unshielded cable in a single conduit. Status LEDs PWR: Power and bootloader status: Power applied: Green - ON. Firmware update in progress: Orange - ON and/or BLINK. COPP: Power delivery (Local unit) or sourcing (Remote Unit) status and/or fault: see the User Guide for Local vs. Remote Unit LED descriptions. DATA - 2-wire data link; Linked: Green - BLINK. SECURITY: Secure mode, pairing mode, and key/config state: Not secure: OFF. Secure: Green - ON. In Config mode: Green - Slow BLINK. In Pairing mode: Green - Fast BLINK. Received key & finished config: Green - 3 BLINKS. Link/ACT - 1GE TP or Fiber port: 1000Mbps: Green - ON link, BLINK activity. 100Mbps: Green and Yellow - ON link, BLINK activity. 10Mbps:Yellow - ON link, BLINK activity. POE - Power Over Ethernet status (Remote PD Unit only): No PD detected: OFF. Power applied: Green - ON. Detect fault: Yellow - ON: Fault or Remote is not a PoE device. Classification fault: Yellow - BLINK. RESET button: If doing security Pairing for 2-wire encryption, do this before final deployment of Local PSE and Remote PD Units in the field. See User Guide for details; the RESET button performs other functions, and you could lose Remote PD Unit connection. Transition Networks 10900 Red Circle Drive * Minnetonka, MN 55343 USA * Tel: +1.952.941.7600 * * Toll Free: 800.526.9267 * Fax: 952.941.2322 * [email protected] * * [email protected] * [email protected] * 33705 Rev. E https://www.transition.com Page 2 of 2

  • 1
  • 2

Transition Networks
EO2Pxx4052-111 Quick Start Guide
33705 Rev. E
Page
2
of
2
Powering the EO2P
The 90W Power supply 25148 is an option for powering the Local PSE unit,
and is optional for use with the Remote PD Unit. The PWR LED blinks to
indicate the presence of power to the EO2Pxx4052-111 (for indoor use only).
48 VDC IN Options
: The two 48 VDC input options are the 4-Pin Mini DIN and
the 2-Pin Terminal Block (right).
Note
: use the flat-topped grip to remove the
power supply cable from the 48VDC IN 4-Pin Mini DIN connection.
Local PSE (
EO2PSE4052-111
) Power Input Options
:
1.
A 4-Pin mini DIN with the designated AC to DC adapter OR
2.
2-Pin Terminal Block connectors for
+
48 VDC power source that
must meet IEEE 802.3 af/at isolation requirements of 1500VAC or
2250 VDC.
Note
:
this must be
+
48 VDC IN.
Remote PD (
EO2PD4052-111
) Power Input Options
:
1.
A 4-Pin mini DIN with the designated AC to DC adapter OR
2.
2-Pin Terminal Block connectors for
+
48 VDC power source that must meet IEEE 802.3 af/at
isolation requirements of 1500VAC or 2250 VDC. OR
3.
PoE input power to the Remote Unit from the Local unit via the 2-wire cable.
Grounding
: An earth ground chassis stud is provided on the back panel. Note that bonding the
earth ground to the chassis stud is required for circuit protection.
Software Operation
Web GUI Configuration
: The Web GUI lets you access the Login page and subsequent
configuration pages (2-Wire, IP, Ethernet, Device, Auto Power Reset, and Advanced) and Status
(Power, SFP, and Remote Upgrade Status) pages.
The default IP address is
192.168.0.1
(Local) and
192.168.0.2
(Remote). The default password is
admin
.
We recommend you change your password
immediately. See the User Guide for notes for installations with multiple pairs of unshielded cable
in a single conduit.
Status LEDs
PWR
: Power and bootloader status: Power applied:
Green
- ON.
Firmware update in progress:
Orange
ON and/or BLINK.
COPP:
Power delivery (Local unit) or sourcing (Remote Unit) status and/or fault: see the
User Guide for Local vs. Remote Unit LED descriptions.
DATA
2-wire data link; Linked:
Green
BLINK.
SECURITY
: Secure mode, pairing mode, and key/config state:
Not secure: OFF. Secure:
Green
ON.
In Config mode:
Green
Slow BLINK. In Pairing mode:
Green
Fast BLINK. Received key & finished config:
Green
3 BLINKS.
Link/ACT
- 1GE TP or Fiber port: 1000Mbps:
Green
- ON link, BLINK activity. 100Mbps:
Green
and Yellow - ON link, BLINK activity.
10Mbps:Yellow - ON link, BLINK activity.
POE
Power Over Ethernet status (Remote PD Unit only): No PD detected: OFF.
Power applied:
Green
ON. Detect fault: Yellow
ON: Fault or Remote is not a PoE device. Classification fault:
Yellow - BLINK.
RESET button
: If doing security Pairing for 2-wire encryption, do this before final deployment of Local PSE and Remote PD Units in
the field. See User Guide for details; the
RESET
button performs other functions, and you could lose Remote PD Unit connection.