Lantronix SLC 32 Lantronix SLC - Product Brief - Page 2

Ordering Information

Page 2 highlights

Features and Specifications > Accessibility • In-Band (Ethernet) - Dual Ethernet ports • Out-of-Band (Local terminal, or Modem) > Security and Authentication • Secure Shell (SSH v1, v2, Public Key) • Packet filtering (firewall) • Per port user permissions • Configurable user rights • Remote authentication: LDAP, NIS, RADIUS, Kerberos, TACACS+ > Serial Device Port Access • Telnet/SSH to SLC command line • Telnet/SSH/RAW-TCP direct to IP address and port number • Web Telnet/SSH • Multiple concurrent Telnet/SSH sessions • Simultaneous access on the same port • No inadvertent "breaks" - Sun break-safe • Customizable multi-level user menus • USB modem access • Automatic port-initiated connections to network host or neighboring port • Enable terminal login on any device port > Data Capture and Notification • Port buffering - 256 KB per port • Port logging to local files, PC card Ext2 & Fat/Fat32, remote • NFS files (simultaneous) • Local logging viewable via CIFS • System event logs • Console event notification (e-mail) • Event string recognition (RegExp) > Management • Front panel keypad/display for network setup • Quick setup and configuration web interface (SSL) • CLI setup script • Command line interface (Telnet, SSH, web telnet/SSH or direct serial) • SNMP (MIB II) compatible - v1, v2, v3, custom MIB's • Integrated power management support (SLP) • Diagnostics and port status counters Performance monitoring utility  Packet generation utility  Network trace utility Configuration audit log • Local subnet search for other SLCs > Additional Protocols Supported • DHCP and BOOTP for dynamic IP address assignment • NTP for time synchronization • FTP,TFTP,SFTP,SCP client for file transfers • DNS for text-to-IP address name resolution • SSH, SSL, Telnet, TCP & UDP, PPP w/PAP/CHAP, NFS and CIFS for connections in and out of the SLC • RIP and RIPv2 > Environmental • Operating Temp: 0°-50°C (32°-122°F) • Storage Temp: -20°-70°C (-4°-158°F) • Relative Humidity: 10 to 90%, non-condensing • Current Measurement Accuracy: +/-12% > Interfaces • Network: Two 10Base-T/100Base-TX RJ45 Ethernet • Devices: 8, 16, 32, or 48 RS-232 (RJ45), 300 to 115200 bps • Console: RS-232 (RJ45), 300 to 115200 bps • USB interface: v1.2 or v2.0 (full speed only) > Operating System • Embedded Linux > Power Requirements • AC input (single or dual): 100-240VAC, 50 to 60 Hz IEC-type cord • DC input: -24 to -60 VDC • Power consumption: Less than 20W max > Environmental • Operating: 0°-50°C (32°-122°F), 30-90%RH, non-condensing • Storage: -20°-70°C (-4°-158°F), 10-90%RH, non-condensing • Heat flow rate: 68 BTU per hour > Physical • Dimensions (LxWxH):30.5 x 43.8 x 4.4cm (12 x 17.25 x 1.75in.), 1U • Weight: 10lbs. maximum, depending on options • Shipping weight: 14lbs. maximum > Certifications • FCC Part 15, CE (EN55022, EN55024, EN60950), CSA, VCCI, TÜV Rheinland, GS Mark, UL/CUL, C-Tick, CB Scheme, NIST-certified implementation of AES (Advanced Encryption Standards) as specified by FIPS-197. > Warranty • 2-year limited warranty Ordering Information United States Call: 800.422.7055 Email: [email protected] Buy Online: http://www.lantronix.com NASDAQ: LTRX Asia/Pacific Call: +852.3428.2338 Email: [email protected] Europe Call: +31 (0) 76.52.3.6.74 4 Email: [email protected] Japan Call: +81.3.6277.8802 Email: [email protected] China Call: +86.021.6237.8868 Email: [email protected] > Part Number > Description SLC00812N-03 SLC8: 8 Port, Single AC Supply Secure Console Manager RoHS SLC00822N-03 SLC8: 8 Port, Dual AC Supply Secure Console Manager RoHS SLC00824N-03 SLC8: 8 Port, Dual DC Supply Secure Console Manager RoHS SLC01612N-03 SLC16: 16 Port, Single AC Supply Secure Console Manager RoHS SLC01622N-03 SLC16: 16 Port, Dual AC Supply Secure Console Manager RoHS SLC01624N-03 SLC16: 16 Port, Dual DC Supply Secure Console Manager RoHS SLC03212N-03 SLC32: 32 Port, Single AC Supply Secure Console Manager RoHS SLC03222N-03 SLC32: 32 Port, Dual AC Supply Secure Console Manager RoHS SLC03224N-03 SLC32: 32 Port, Dual DC Supply Secure Console Manager RoHS SLC04812N-03 SLC48: 48 Port, Single AC Supply Secure Console Manager RoHS SLC04822N-03 SLC48: 48 Port, Dual AC Supply Secure Console Manager RoHS SLC04824N-03 SLC48: 48 Port, Dual DC Supply Secure Console Manager RoHS > Accessories > Description 200.2066A 200.2067A 200.2069A 200.2070A ADP010104 500-137 500-153 RJ45 to DB25M Cable Adapter RJ45 to DB25F Cable Adapter RJ45 to DB9M Cable Adapter RJ45 to DB9F Cable Adapter Cable; rolled serial adapter, 0.1m (0.33 ft) Cable; Rolled Serial, RJ45 to RJ45, 3m (9.8 ft.) Cable; Loopback Back view of the SLC16 SLC Deployment Example SLC16 Winner of the Network Computing Editor's Choice Award © Lantronix, Inc. 2013. All rights reserved. Lantronix is a registered trademark of Lantronix, Inc. in the U.S. and other countries. All other trademarks and trade names are the property of their respective holders. 940-050-R Rev B

  • 1
  • 2

Features and Specifications
>
Accessibility
• In-Band (Ethernet) - Dual Ethernet ports
• Out-of-Band (Local terminal, or Modem)
>
Security and Authentication
• Secure Shell (SSH v1, v2, Public Key)
• Packet filtering (firewall)
• Per port user permissions
• Configurable user rights
• Remote authentication: LDAP, NIS, RADIUS, Kerberos, TACACS+
>
Serial Device Port Access
• Telnet/SSH to SLC command line
•Telnet/SSH/RAW-TCP direct to IP address and port number
•Web Telnet/SSH
• Multiple concurrent Telnet/SSH sessions
• Simultaneous access on the same port
• No inadvertent “breaks” – Sun break-safe
• Customizable multi-level user menus
• USB modem access
• Automatic port-initiated connections to network host or
neighboring port
• Enable terminal login on any device port
>
Data Capture and Notification
• Port buffering — 256 KB per port
• Port logging to local files, PC card Ext2 & Fat/Fat32,
remote
• NFS files (simultaneous)
• Local logging viewable via CIFS
• System event logs
• Console event notification (e-mail)
• Event string recognition (RegExp)
>
Management
• Front panel keypad/display for network setup
• Quick setup and configuration web interface (SSL)
• CLI setup script
• Command line interface (Telnet, SSH, web telnet/SSH or
direct serial)
• SNMP (MIB II) compatible - v1, v2, v3, custom MIB’s
• Integrated power management support (SLP)
• Diagnostics and port status counters
Performance monitoring utility
Packet generation utility
Network trace utility
Configuration audit log
• Local subnet search for other SLCs
>
Additional Protocols Supported
• DHCP and BOOTP for dynamic IP address assignment
• NTP for time synchronization
•FTP,TFTP,SFTP,SCP client for file transfers
• DNS for text-to-IP address name resolution
•SSH, SSL, Telnet, TCP & UDP, PPP w/PAP/CHAP, NFS and
CIFS for connections in and out of the SLC
• RIP and RIPv2
>
Environmental
• Operating Temp: 0°-50°C (32°-122°F)
• Storage Temp: -20°-70°C (-4°-158°F)
• Relative Humidity: 10 to 90%, non-condensing
• Current Measurement Accuracy: +/-12%
>
Interfaces
•Network: Two 10Base-T/100Base-TX RJ45 Ethernet
• Devices: 8, 16, 32, or 48 RS-232 (RJ45), 300 to 115200 bps
• Console: RS-232 (RJ45), 300 to 115200 bps
• USB interface: v1.2 or v2.0 (full speed only)
>
Operating System
• Embedded Linux
>
Power Requirements
• AC input (single or dual): 100-240VAC, 50 to 60 Hz
IEC-type cord
• DC input: -24 to -60 VDC
• Power consumption: Less than 20W max
>
Environmental
• Operating: 0°-50°C (32°-122°F), 30-90%RH, non-condensing
• Storage: -20°-70°C (-4°-158°F), 10-90%RH, non-condensing
• Heat flow rate: 68 BTU per hour
Ordering Information
Asia/Pacific
Call:
+852.3428.2338
Email:
Europe
Call:
+31 (0) 76.52.3.6.74 4
Email:
United States
Call:
800.422.7055
Email:
Buy Online:
NASDAQ:
LTRX
>
Part Number
>
Description
SLC00812N-03
SLC8: 8 Port, Single AC Supply Secure Console Manager RoHS
SLC00822N-03
SLC8: 8 Port, Dual AC Supply Secure Console Manager RoHS
SLC00824N-03
SLC8: 8 Port, Dual DC Supply Secure Console Manager RoHS
SLC01612N-03
SLC16: 16 Port, Single AC Supply Secure Console Manager RoHS
SLC01622N-03
SLC16: 16 Port, Dual AC Supply Secure Console Manager RoHS
SLC01624N-03
SLC16: 16 Port, Dual DC Supply Secure Console Manager RoHS
SLC03212N-03
SLC32: 32 Port, Single AC Supply Secure Console Manager RoHS
SLC03222N-03
SLC32: 32 Port, Dual AC Supply Secure Console Manager RoHS
SLC03224N-03
SLC32: 32 Port, Dual DC Supply Secure Console Manager RoHS
SLC04812N-03
SLC48: 48 Port, Single AC Supply Secure Console Manager RoHS
SLC04822N-03
SLC48: 48 Port, Dual AC Supply Secure Console Manager RoHS
SLC04824N-03
SLC48: 48 Port, Dual DC Supply Secure Console Manager RoHS
>
Accessories
>
Description
200.2066A
RJ45 to DB25M Cable Adapter
200.2067A
RJ45 to DB25F Cable Adapter
200.2069A
RJ45 to DB9M Cable Adapter
200.2070A
RJ45 to DB9F Cable Adapter
ADP010104
Cable; rolled serial adapter, 0.1m (0.33 ft)
500-137
Cable; Rolled Serial, RJ45 to RJ45, 3m (9.8 ft.)
500-153
Cable; Loopback
SLC Deployment Example
© Lantronix, Inc. 2013. All rights reserved. Lantronix is a registered trademark of Lantronix, Inc. in the U.S. and other countries. All other trademarks and trade names are the property of their respective holders.
940-050-R Rev B
>
Physical
• Dimensions (LxWxH):30.5 x 43.8 x 4.4cm (12 x 17.25 x 1.75in.), 1U
• Weight: 10lbs. maximum, depending on options
• Shipping weight: 14lbs. maximum
>
Certifications
• FCC Part 15, CE (EN55022, EN55024, EN60950), CSA, VCCI, TÜV Rheinland,
GS Mark, UL/CUL, C-Tick, CB Scheme, NIST-certified implementation of AES
(Advanced Encryption Standards) as specified by FIPS-197.
>
Warranty
• 2-year limited warranty
Back view of the SLC16
SLC16 Winner of the
Network Computing
Editor’s Choice
Award
Japan
Call:
+81.3.6277.8802
Email:
China
Call:
+86.021.6237.8868
Email: