Lantronix XPress-DR-IAP UDS1100-IAP - Multi-Master DF1 Protocol User Guide
Lantronix XPress-DR-IAP Manual
View all Lantronix XPress-DR-IAP manuals
Add to My Manuals
Save this manual to your list of manuals |
Lantronix XPress-DR-IAP manual content summary:
- Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 1
Multi-Master DF1 Protocol User Guide Part Number 900-282 Revision B August 2004 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 2
- Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 3
Fax: 949-450-7226 Online: www.lantronix.com/support Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at http://www.lantronix.com/about/contact/index.html. Disclaimer & Revisions The information in this guide may change without notice. The - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 4
Mode over Telnet 7 TCP/IP Network Settings 8 DF1 Settings 9 MSG Block Remote IP Routing Table 10 Save, Quit, or Reset the Configuration 12 4: Q & A 13 5: Technical Support 15 Figures Figure 2-1. Computer to PLC ...5 Figure 2. - PLC to PLC ...5 Multi-Master DF1 Protocol User - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 5
. An IAP Device Server with Lantronix Standard Tunneling Industrial Automation solutions, see http://www.lantronix.com/solutions/industrial Lantronix Com Port Redirector software on the Windows computer to port 3001. Full instructions are in the Tech Tips section of http://automation.lantronix Guide 4 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 6
PLC The Multi-Master DF1 firmware allows four incoming and one outgoing socket to be active at one time. This means in a simple example, that IAP Device Server-C with Multi-Master DF1 firmware can allow sockets from IAP Device Server-A, IAP Device Multi-Master DF1 Protocol User Guide 5 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 7
, as the Multi-Master DF1 firmware only supports four active incoming sockets at one time. Note that the standard firmware in IAP Device Server-A and IAP Device Server-B should be set up as expected for a serial tunnel (see the Standard Tunneling Manual). Setting Flush Mode to 0x11 causes all stale - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 8
Lantronix provides an intelligent Ethernet-enabling technology for the most commonly used Industrial Serial Protocols, including DF1. You must configure certain parameters before the IAP Device Server Setup Mode Model: IAP Device Server Plus+! (Firmware Code reflashed the IAP Device Server with Multi - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 9
Enter after each octet. The IP address must be set to a unique value in your network. To learn more about IP addressing, see the User Guide for your IAP Device Server. Note: The IAP Device Server will not connect to the network if the assigned IP address is already in use by another - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 10
CheckSum? (Y) Y You have 4 total incoming sockets: Number to use for Lantronix Redirector (00002) ?3 Number to use for Raw DF1 in TCP 1 TCP At the Enter Serial Parameters prompt, enter the serial settings matching the serial device. Separate each entry by a comma. Press Enter. 4. Enter a Guide 9 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 11
IP Routing Table This is the mapping information that forwards or routes a DF1 message originated by the serial DF1 device. The DF1 firmware uses the DST (or destination) byte of the DF1 message to select (and possibly like 192.168.0.255 as a broadcast. Multi-Master DF1 Protocol User Guide 10 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 12
. 1. On lines 1-5, enter the fixed and/or dynamic IP addresses or address ranges that correspond to the message blocks in your PLC or serial device. Press Enter between each entry. 2. Press Enter. The window refreshes and displays all of your entries. Note: You must save your settings to apply - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 13
without saving, type Q on the command line. The unit reboots. To restore the default values, type R on the command line. Multi-Master DF1 Protocol User Guide 12 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 14
& A Can I use the Lantronix IAP Device Server with Multi-Master DF1 to link chosen the most generic, widely applicable way to support DF1 with TCP/IP. Does the IAP Device Server with Multi-Master DF1 autobaud? No, you must manually set the baud rate to match your PLC DF1 Protocol User Guide 13 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 15
modem cable is used to connect the IAP Device Server to the KF3 device. DH+ Networks An Allen Bradley KF2 or compatible device is needed to connect to the DH+ network. A standard null modem cable is used to connect the IAP Device Server to the KF2 device. Multi-Master DF1 Protocol User Guide 14 - Lantronix XPress-DR-IAP | UDS1100-IAP - Multi-Master DF1 Protocol User Guide - Page 16
East, and Africa: Phone: +49 (0) 89 31787 817 Email: [email protected] Firmware downloads, FAQs, and the most up-to-date documentation are available at: http://www.lantronix.com/support When you report a problem, please provide the following information: Your name, and your company name
Part Number 900-282
Revision B
August 2004
Multi-Master DF1 Protocol