Lenovo Storage S2200 (English) Command Line Interface Reference Guide - Lenovo - Page 109
Optional. Enables or disables SMART Self-Monitoring Analysis and Reporting Technology monitoring
View all Lenovo Storage S2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
managed-logs enabled|disabled|on|off Optional. Enables or disables the managed logs feature, which allows log files to be transferred from the storage system to a log collection system to avoid losing diagnostic data. • disabled or off: The managed logs feature is disabled. This is the default. • enabled or on: The managed logs feature is enabled. missing-lun-response notready|illegal Optional. Sets whether host drivers may probe for LUNs until the host drivers reach the LUN to which they have access. • notready: Sends a reply that there is a LUN where a gap has been created but that it's "not ready." Sense data returned is sensekey = 2, code = 4, qualifier = 3. This option is the default. • illegal: Sends a reply that there is a LUN but that the request is "illegal." Sense data returned is sensekey = 5, code = 25h, qualifier = 0. If the system is used in a VMware environment, use this option. partner-firmware-upgrade enabled|disabled|on|off Optional. Sets whether component firmware versions are monitored and will be automatically updated on the partner controller. You cannot enable this parameter if the independent-cache parameter is enabled. • disabled or off: Partner firmware upgrade is disabled. • enabled or on: Partner firmware upgrade is enabled. This is the default. partner-notify enabled|disabled|on|off Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this option to have the partner also change to write-through mode for better data protection. Disable this option to allow the partner continue using its current caching mode for better performance. The default is disabled. • disabled or off: Notification is disabled. This is the default. • enabled or on: Notification is enabled. power-supply-failure enabled|disabled|on|off Optional. Sets whether the cache policy automatically changes to write-through when a power supply fails. • disabled or off: The power-supply failure trigger is disabled. This is the default. • enabled or on: The power-supply failure trigger is enabled. single-controller Optional; for use by a service technician only. For a system that had two controller modules but now has only one and is intended to be used as a single-controller system, this parameter changes the operating/redundancy mode to Single Controller. This prevents the system from reporting the absent partner controller as an error condition. This parameter does not affect any other system settings. Installing a second, functional controller module will change the mode to Active-Active ULP. You cannot enable this parameter if the independent-cache parameter is enabled. smart enabled|disabled|on|off|detect-only Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology) monitoring for all disks in the storage system. • disabled or off: Disables SMART for all disks in the system and for all disks added to the system. • enabled or on: Enables SMART for all disks in the system and for all disks added to the system. This is the default. • detect-only: Detects but does not change the SMART setting of each disk in the system, and for each new disk added to the system. set advanced-settings 109