- Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 1
Lenovo Storage S3200/S2200 Setup Guide For firmware release GL210 or later Abstract This document describes initial hardware setup for Lenovo Storage S3200/S2200 controller enclosures, and is intended for use by storage system administrators familiar with servers and computer networks, network - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 2
RIGHTS NOTICE: If data or software is delivered pursuant a General Services Administration "GSA" contract, use, reproduction, or disclosure is subject to restrictions set forth in Contract No. GS-35F-05925. Lenovo, the Lenovo logo, BladeCenter, Flex System, NeXtScale System, and System x are - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 3
panel components 13 12-drive enclosure front panel components 14 Disk drives used in S3200/S2200 enclosures 15 Controller enclosure - SAS controller module - rear panel components 18 E1024/E1012 drive enclosure rear panel components 19 Component Lenovo Storage S3200/S2200 Setup Guide 3 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 4
45 Configuring and provisioning the storage system 45 5 Troubleshooting 46 USB CLI port connection Service Required LED amber 50 Are both disk drive module LEDs off 50 Is the disk drive module Fault LED amber 50 Is a connected host port Host Link Status LED on 51 Is a connected port Expansion - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 5
front panel LEDs 59 Disk drive LEDs 60 LEDs 69 E1024/E1012 drive port 77 Supported host applications Problem 79 Workaround 79 E SFP option for CNC ports 80 Locate the SFP transceivers 80 Install an SFP transceiver 80 Verify component operation 81 Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 6
F SAS fan-out cable option 82 Locate the SAS fan-out cable 82 Install the SAS fan-out cable 82 Index 84 6 Contents - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 7
36 LEDs: 2U12 enclosure front panel 59 37 LEDs: Disk drive modules 60 38 S3200/S2200 controller enclosure: rear panel 45 LEDs: AC power supply unit - rear panel 69 46 LEDs: E1024/E1012 drive enclosure - rear panel 70 47 Rackmount enclosure dimensions 73 Lenovo Storage S3200/S2200 Setup Guide 7 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 8
panel "Fault/Service Required 50 10 Diagnostics LED status: Disk drives (LFF and SFF modules 50 11 Diagnostics LED status: Disk drive fault status (LFF and SFF modules 50 12 Diagnostics LED status: Rear panel "Host Link Status 51 13 Diagnostics LED status: Rear panel "Expansion Port Status 51 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 9
) and European Telco requirements. The S3200/S2200 storage enclosures support a large form factor (LFF 12-disk) 2U chassis and a small form factor (SFF 24-disk) 2U chassis. These chassis form factors support controller enclosures and expansion enclosures. The S3200/S2200 controller enclosures can - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 10
44 for instructions). HD support a link rate of 12 Gbit/s using the qualified connectors and cable options. See S3200 SAS controller module-rear panel LEDs on page 65 and S2200 SAS controller module-rear panel LEDs on page 68 for more information. Intended audience This guide is intended for storage - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 11
Environmental and Notices Guide • Basic Troubleshooting Guide • Rack Safety Information • Safety Information • Safety Labels Overview of product shipkit contents and setup tasks Lenovo Storage S3200/S2200 Getting Started* Multilingual warranty, service and support information Lenovo Warranty* and - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 12
at the command-line CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. 12 About this - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 13
1 Components Front panel components Lenovo Storage S3200/S2200 supports 2U24 and 2U12 enclosures in dual-purpose fashion. The 2U24 chassis-configured with 24 2.5" small form factor (SFF) disks-is used as either a controller enclosure or expansion enclosure. The 2U12 chassis-configured with 12 3.5" - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 14
8 (Silk screens on bezel) 1 Enclosure ID LED 2 Disk drive status LED: Fault 3 Disk drive status LED: Power/Activity 4 3.5" disk or drive blank (typical 12 slots) 5 Enclosure status LED: Unit Locator 6 Enclosure status LED: Fault/Service Required 7 Enclosure status LED: CRU OK 8 Enclosure status - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 15
, and SFF SSD disks. They also support LFF/SFF Midline SAS and LFF/SFF Enterprise self-encrypting disks that work with the Full Disk Encryption (FDE) feature. For information about creating disk groups and adding spares using different disk drive types, see the Lenovo Storage Manager Guide or online - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 16
) 8 mini-SAS expansion port Figure 5 S3200 CNC controller module face plate (1 Gb RJ-45) NOTE: See CNC ports used for host connection on page 10 for more information about CNC technology. For CNC port configuration, see the "Configuring host ports" topic within the Storage Manager Guide or online - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 17
6 Service port 1 (used by service personnel only) 7 Disabled button (used by engineering only) (Sticker shown covering the opening) 4 Reserved for future use 8 mini-SAS expansion port Figure 7 S2200 CNC controller module face plate (FC or 10GbE iSCSI) Lenovo Storage S3200/S2200 Setup Guide 17 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 18
ports" topic within the Storage Manager Guide or online help. S2200 SAS controller module - rear panel components Figure 9 shows host interface ports configured with 12 Gbit/s HD mini-SAS (SFF-8644) connectors. 1 5 7 12Gb/s 6Gb/s LINK LINK SAS 0 SAS 1 ACT ACT SERVICE−2 CLI ACT CLI - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 19
panel components S3200/S2200 controller enclosures support SFF E1024 24-disk and LFF E1012 12-disk drive enclosures in the 2U form factor for expansion of storage capacity. These drive enclosures use mini-SAS (SFF-8088) connectors to facilitate backend SAS expansion. The rear panel view is common - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 20
For additional information, contact support.lenovo.com, select Product Support, and navigate to Storage Products. NOTE: In event of a power failure. Unwritten data in CompactFlash memory is automatically committed to disk media when power is restored. In the event of power failure, while cache is - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 21
instructions disk drive modules, follow the same procedures for installing disks that do not support FDE. The exception occurs when you move FDE-capable disk drive modules for one or more disk groups to a different system, which requires additional steps. Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 22
CRU, you must insert the original disks and re-enter their FDE passprhase (see the CRU Installation and Replacement Guide for more information). Connecting the controller enclosure and drive enclosures Lenovo Storage S3200/S2200 controller enclosures support these maximum configurations: • S3200 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 23
-rate SFF and LFF expansion modules-in mixed model fashion-as shown in Figure 13 on page 26. The simplified rear-panel views of the E1024 and E1012 are identical. Cable requirements for storage enclosures The S3200/S2200 enclosures support 6-Gbps or 3-Gbps expansion port data rates. Use only Lenovo - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 24
expansion) enclosures relative to cabling, including: the cable type needed for attaching one specific enclosure model to another specific enclosure model; internal disk drive speeds; number of disks of given size (SFF or LFF) supported mini-SAS mini-SAS to mini-SAS E1024 2U24 Note 4 mini-SAS to - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 25
. The rear-panel views of the E1024 and E1012 are identical. All storage enclosures use mini-SAS connectors for expansion. NOTE: The S3200/S2200 controller enclosures and compatible drive enclosures support 6 Gb SFF-8088 mini-SAS connectors for adding storage. See Table 4 for SAS cable requirements - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 26
above) shows the same storage components connected using straight-through cabling. Using this method, if an expansion enclosure fails, the either be of the same type (all E1024s or all E1012s) or they can be a mixture of these models. Given that supported drive enclosure models use 6 Gb SAS - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 27
between a dual-controller enclosure and seven 2U drive enclosures The diagrams above show dual-controller enclosures cabled to drive enclosures featuring dual-expansion modules. Cabling logic is explained in the narrative supporting Figure 13 on page 26. Lenovo Storage S3200/S2200 Setup Guide 27 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 28
installed within enclosures. Once the power-on sequence succeeds, the storage system is ready to be connected to hosts as described in off Before powering on the enclosure for the first time: • Install all disk drives in the enclosure so the controller can identify and configure them at power - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 29
(see Figure 15 and Figure 16). Wait several seconds to allow the disks to spin up. Repeat this sequence for each switchless PSU within each drive : • Use the Storage Management Console to shut down both controllers as described in the online help and Lenovo Storage Manager Guide. Proceed to step - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 30
and the storage. • Use native Microsoft MPIO DSM support with disk group ownership. TIP: See "Using the Configuration Wizard" in the Storage Manager Guide to initially configure the system or change system configuration settings (such as Configuring host ports). CNC technology Certain Lenovo Storage - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 31
for instructions). Fibre Channel protocol S3200/S2200 FC controller enclosures support one supporting data rates up to 1 Gbit/s, using either one-way or mutual CHAP (Challenge-Handshake Authentication Protocol). The 1 Gb iSCSI ports are used for attachment to 1 Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 32
host computer must support Ethernet, iSCSI, and optionally, multipath I/O. TIP: See the "Configuring CHAP" topic in the Storage Management Guide. TIP: Use . Use a qualified SFF-8644 to SFF-8088 option when connecting to a supported 6 Gbit/s host. S3200 host ports support standard cables; whereas - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 33
. If the controller fails, the host loses access to the storage data. This configuration is suitable only in environments where high availability is not required, and loss of access to data can be tolerated until failure recovery actions are completed. Lenovo Storage S3200/S2200 Setup Guide 33 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 34
One server/one HBA/single path S3200 CNC Server S 6Gb/s A S 0A IOM blank 0B S3200 SAS Server S 12Gb/s A S S 12Gb/s A S S 6Gb/s A S IOM blank 0A 0B Figure 17 Connecting hosts: S3200 direct attach-one server/one HBA/single path S2200 CNC Server 6Gb/s 0A IOM blank 0B - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 35
See the "Replacing a controller or expansion module" topic within the CRU Installation and Replacement Guide for additional information about installing IOMs. Dual /s 6Gb/s 0A 0B Figure 21 Connecting hosts: S2200 direct attach-one server/one HBA/dual path Lenovo Storage S3200/S2200 Setup Guide 35 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 36
Two servers/one HBA per server/dual path S3200 CNC Server 1 S 6Gb/s A S S 6Gb/s A S 0A 0B Server 2 S3200 SAS Server 1 S 12Gb/s A S S 12Gb/s A S S 12Gb/s A S S 12Gb/s A S S 6Gb/s A S S 6Gb/s A S 0A 0B Server 2 Figure 22 Connecting hosts: S3200 direct attach-two - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 37
2 Server 3 S 12Gb/s A S S 12Gb/s A S S 12Gb/s A S S 12Gb/s A S S 6Gb/s A S S 6Gb/s A S 0A 0B Server 4 Figure 26 Connecting hosts: S3200 direct attach-four servers/one HBA per server/dual path Lenovo Storage S3200/S2200 Setup Guide 37 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 38
for a particular environment. Using switches increases the number of servers that can be connected to the storage system. A S3200/S2200 controller enclosure supports 64 hosts. Dual-controller configuration Two servers/two switches S3200 CNC Server 1 Server 2 Switch A S 6Gb/s A S S 6Gb - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 39
.255.0): • Controller A port 0: 10.10.10.100 • Controller A port 1: 10.11.10.120 • Controller B port 0: 10.10.10.110 • Controller B port 1: 10.11.10.130 Lenovo Storage S3200/S2200 Setup Guide 39 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 40
storage system components for the first time, verify that the controller modules, expansion modules, and disk drives are using the current firmware release. Using the Storage partner-firmware-upgrade parameter. See the CLI Reference Guide for more information about command parameter syntax. - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 41
the CLI port and cable If you did not use DHCP to set network port IP values, set them manually as described below. If you are using the USB CLI port and cable, you will need to enable as shown in Figure 30 on page 42 (generic S3200 controller module shown). Lenovo Storage S3200/S2200 Setup Guide 41 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 42
Not ISnhteorwfance CLI SERVICE−2 CLI ACT LINK SERVICE−1 6Gb/s CACHE page 78, and follow the instructions provided for proper installation. 4. ANSI (for color support) Terminal None 80 laptop configuration determines which COM port is used for Disk Array USB Port. 2Verify the appropriate COM port - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 43
, incorrect command syntax in a HyperTerminal session can cause the CLI to hang. To avoid this problem, use correct syntax, use a different terminal emulator, or connect to the CLI using telnet rather Otherwise, the host's CPU cycles may rise unacceptably. Lenovo Storage S3200/S2200 Setup Guide 43 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 44
the controller modules restart. • See Appendix E-SFP option for CNC ports for instructions about locating and installing your qualified SFP transceivers within the CNC ports. After changing configuration settings as described in the Storage Manager Guide and Basic operation. 44 Connecting hosts - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 45
that you have successfully completed the sequential "Installation Checklist" instructions in Table 3 on page 21. Once you have successfully missing LUN response" in the Storage Manager Guide or the command topic "set-advanced-settings" in the CLI Reference Guide. Lenovo Storage S3200/S2200 Setup - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 46
5 Troubleshooting USB CLI port connection Lenovo Storage S3200/S2200 controllers feature a CLI port employing a mini-USB Type B form factor. If you encounter problems communicating with the port after cabling your computer to the USB device, you may need to either download a device driver (Windows), - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 47
of the following severities: • Critical. A failure occurred that may cause a controller to shut down. Correct the problem immediately. • Error. A failure occurred that may affect data integrity or system stability. Correct the problem as soon as possible. Lenovo Storage S3200/S2200 Setup Guide 47 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 48
available, due to either Single Controller configuration or controller failure, a manual rescan will not reorder the drive enclosure IDs. Stopping I/O When troubleshooting disk drive and connectivity faults, stop I/O to the affected disk groups from all hosts as a data protection precaution. As an - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 49
to determine if data is being written to or read from the disk group. Record the numbers displayed. 3. To determine if any reads or Lenovo for assistance. Replacement may be necessary. Table 7 Diagnostics LED status: Front panel "Fault/Service Required" Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 50
"CRU OK" Is the controller back panel Fault/Service Required LED amber? Answer Possible reasons Actions No Lenovo for assistance. Table 11 Diagnostics LED status: Disk drive fault status (LFF and SFF modules) NOTE: See FDE considerations on page 21 for S3200 enclosures. 50 Troubleshooting - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 51
Host Link Status" Is a connected port Expansion Port Status LED on? Answer Possible reasons troubleshooting procedures to isolate faults on the network. • Contact Lenovo for assistance. Table 14 Diagnostics LED status: Rear panel "Network Port Link Status" Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 52
unit. Table 16 Diagnostics LED status: Rear panel power supply "Voltage/Fan Fault/Service Required" For additional information, contact support.lenovo.com, select Product Support, and navigate to Storage Products. Controller failure in a single-controller configuration Cache memory is flushed to - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 53
problem support.lenovo.com, select Product Support, and navigate to Storage Products. Host-side connection troubleshooting featuring SAS host ports For additional information, contact support.lenovo.com, select Product Support, and navigate to Storage Products. Isolating a controller module expansion - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 54
storage system monitors conditions at different points within each enclosure to alert you to problems. Power, cooling fan, temperature, and voltage sensors are located at key points in the enclosure. In each controller module and expansion power supply has one temperature sensor. 54 Troubleshooting - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 55
Sensor Power supply 1 voltage, 12V Power supply 1 voltage, 5V Power supply 1 voltage, 3.3V Event/Fault LED condition < 11.00V > 13.00V < 4.00V > 6.00V < 3.00V > 3.80V Lenovo Storage S3200/S2200 Setup Guide 55 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 56
disks-is also used as either a controller enclosure or expansion enclosure. Supported expansion enclosures are used for adding storage. The E1012 12-drive enclosure is the LFF drive enclosure used for storage expansion. The E1024 24-drive enclosure is the SFF serviceable the instructions provided. - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 57
NOTE: The dual-purpose 2U24 and 2U12 enclosure front panel illustrations that follow assume that you have removed the enclosure bezel to reveal underlying components. Lenovo Storage S3200/S2200 Setup Guide 57 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 58
LEDs-including SFF disk LEDs-are Disk drive - Left LED 3 Disk drive - Right LED 4 Unit Locator 5 Fault/Service Disk drive LEDs on page 60. White blink - Enclosure is identified Off - Normal operation Amber - On Enclosure-level fault condition exists. The event has been acknowledged but the problem - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 59
(Silk screens on bezel) LED Description 1 Enclosure ID 2 Disk drive - Upper LED 3 Disk drive - Lower LED 4 Unit Locator 5 Fault/Service Required 6 CRU OK 7 Temperature Fault Definition Green - On properly installed while the enclosure is in operation. Lenovo Storage S3200/S2200 Setup Guide 59 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 60
drive modules For information about disk drive types supported in S3200/S2200 LFF and SFF disk drive modules, see Disk drives used in S3200/S2200 enclosures on page 15. For information about replacing a disk drive module in an S3200/S2200 controller enclosure or an E1024/E1012 drive enclosure, see - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 61
Disk group degraded Disk group is critical/down LFF/SFF disks Color Action Green On Green Blink Green Blink See note 1 below 1Individual disks will display fault LEDs NOTE: Disk LED descriptions within this section relate to 2U24 and 2U12 enclosures. Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 62
3 SERVICE−2 CLI ACT CLI LINK SERVICE−1 PORT 0 PORT 1 PORT 2 PORT 3 SERVICE−2 CLI ACT CLI LINK SERVICE−1 6Gb Service port 1 (used by service personnel only) 10 Disabled button (used by engineering/test only) (Stickers shown covering the openings) 11 SAS expansion enclosures supported by - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 63
operating normally. 8 Fault/Service Required Amber - A fault has been detected or a service action is required. Blinking cache activity. See also Cache Status LED details on page 69. 10 Expansion Port Status Off - The port is empty or the link is down Lenovo Storage S3200/S2200 Setup Guide 63 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 64
supported combinations of host interface protocols using CNC ports, see CNC ports used for host connection on page 10 and the "Configuring host ports topic" in the Storage Management Guide. 1 5 7 PORT 0 PORT 1 PORT 2 PORT 3 SERVICE−2 CLI ACT CLI LINK SERVICE 69. 10 Expansion Port Status - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 65
3 SERVICE−2 CLI ACT CLI 2 3 LINK SERVICE−1 10 Expansion Port SFF-8644 to SFF-8088 cable option when connecting the S3200 SAS controller to a 6 Gb SAS HBA. 4When port is down, both LEDs are off. Figure 41 LEDs: S3200 SAS controller module (HD mini-SAS) Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 66
module is operating normally. 8 Fault/Service Required Amber - A fault has been detected or a service action is required. Blinking amber - , indicating cache activity. See also Cache Status LED details on page 69. 10 Expansion Port Status Off - The port is empty or the link is down. On - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 67
operating normally. 8 Fault/Service Required Amber - A fault has been detected or a service action is required. Blinking cache activity. See also Cache Status LED details on page 69. 10 Expansion Port Status Off - The port is empty or the link is down Lenovo Storage S3200/S2200 Setup Guide 67 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 68
Fault/Service Required Amber - A fault has been detected or a service action Cache Status LED details on page 69. 10 Expansion Port Status Off - The port is empty or SFF-8644 to SFF-8644 cable option when connecting the S2200 SAS controller to a 12 Gb SAS HBA. 3Use a qualified SFF-8644 to SFF - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 69
boots, finds data preserved in cache, and writes it to disk. This means the system can be operational within 30 seconds, Power Good Color Green State On Off 2 - Voltage/Fan Fault/Service Amber On Required Off Definition Power is on and input voltage is Lenovo Storage S3200/S2200 Setup Guide 69 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 70
/E1012 drive enclosure rear panel LEDs The rear panel layout of a 2U (E1024/E1012) drive enclosure is shown below. Using mini-SAS (SFF-8088) external connectors, these drive enclosures support a 6-Gbps data rate for backend SAS expansion. See Powering on/powering off on page 28 for more information - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 71
local safety codes and regulations at the facility site. Follow all cautions and instructions marked on the equipment. Site requirements and guidelines The following sections provide an enclosure depends on the number and type of modules installed. Lenovo Storage S3200/S2200 Setup Guide 71 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 72
by removing the power supply modules and disk drive modules. • Do not place enclosures which you might move the rack can support the weight. To prevent accidents when moving of an enclosure to allow access to enclosure components for servicing. Removing a component requires a clearance of at least - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 73
21.6 59.9 23.6 .1The 2U24 enclosure uses 2.5" SFF disks. Remove the enclosure bezel to view disk drive module LEDs. 2The 2U12 enclosure uses 3.5" LFF disks. Remove the enclosure bezel to view disk drive module LEDs. Figure 47 Rackmount enclosure dimensions Lenovo Storage S3200/S2200 Setup Guide 73 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 74
S3200/S2200 controller enclosures. Table 27 Rackmount compatible drive enclosure weights (ordered separately) Specifications E1024 (SFF 2.5" 24-drive enclosure) • Chassis with FRUs (no disks)1-3 • Chassis with FRUs (including disks)1-4 E1012 (LFF 3.5" 12-drive enclosure) • Chassis with FRUs (no - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 75
. To ensure power redundancy, connect the two power cables to two separate circuits; for example, to one commercial circuit and one uninterruptible power source (UPS). Lenovo Storage S3200/S2200 Setup Guide 75 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 76
floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you with product installation, contact support.lenovo.com, select Product Support, and navigate to Storage Products. 76 Electrostatic discharge - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 77
Host Not ISnhteorwfance CLI SERVICE−2 CLI ACT LINK SERVICE−1 6Gb/s CACHE DIRTY be created or modified (see Follow the instructions accompanying the device driver topic for Microsoft Supported host applications). Serial port configuration is unnecessary. Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 78
that the management computer has Internet access. 2. See Lenovo's customer support website: support.lenovo.com. a. Select Product Support, and navigate to Storage Products. Peruse the location for information about the "USB driver." b. Follow the instructions accompanying the device driver topic for - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 79
when the MC is restarted (any supported terminal emulator): 1. If the connection Disk Array USB Port (COMn), and select Enable. 3. Start the terminal emulator and connect to the COM port. 4. Set network port IP addresses using the CLI (see procedure on page 41). Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 80
to the generic SFP shown in the figures below. Controller module face plate PORT 0 PORT 1 Target CNC port PORT 2 PORT 3 CLI SERVICE−2 CLI ACT LINK SERVICE−1 6Gb/s CACHE DIRTY LINK PORT 1 PORT 1 Installed SFP (actuator closed) Align SFP for installation (plug removed/actuator open) Fibre - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 81
module face plate. A green LED indicates that the port is connected and the link is up (see LED descriptions for information about controller module LEDs). Lenovo Storage S3200/S2200 Setup Guide 81 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 82
appropriate qualified SAS fan-out cable option for your 2-port SAS controller module. Qualified fan-out cable options are described within Cable requirements for storage enclosures on page 23 and HD mini-SAS host connection on page 33. Cabling examples showing use of SAS fan-out cables are provided - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 83
of the bifurcated HD mini-SAS to mini-SAS cable show orientation for connection to the controller module (on left) and the host (on right). Lenovo Storage S3200/S2200 Setup Guide 83 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 84
E1024/ expansion port 16, 17 network port 16, 17 service port 1 16, 17 service disk drive LEDs general 60 specific states 61 document conventions 12 prerequisite knowledge 10 related documentation 11 E electrostatic discharge grounding methods 76 precautions 76 Lenovo Storage S3200/S2200 Setup Guide - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 85
Locator 63, 64 S3200 SAS 12 Gb Host Link Activity 65 12 Gb Host Link Status 65 Cache Status 65 CRU OK 65 Expansion Port Status 65 Fault/Service Required 65 Network Port Link Active 65 Network Port Link Speed 65 OK to Remove 65 Unit Locator 65 Lenovo Storage S3200/S2200 Setup Guide 85 - Lenovo Storage S3200 | (English) Setup Guide - Lenovo Storage S3200, S2200 - Page 86
troubleshooting 46 controller failure, single controller configuration 52 correcting enclosure IDs 48 enclosure does not initialize 48 expansion device driver 78 emulated serial port 77 rear panel USB ports 77 supported host applications 78 vendor and product ID codes 78 V ventilation requirements
Lenovo Storage S3200/S2200
Setup Guide
For firmware release GL210 or later
Part Number: 00WE606
Abstract
This document describes initial hardware setup for Lenovo Storage S3200/S2200 controller enclosures, and is intended for use by
storage system administrators familiar with servers and computer networks, network administration, storage system installation and
configuration, storage area network management, and relevant protocols.