Lenovo Y40-80 Laptop Hardware Maintenance Manual - Lenovo Y40 50 Series - Page 61

M2.0 × 6.5 mm, flat-head, nylok-coated 6, THERMAL MODULECPU to MB Y50-70

Page 61 highlights

Lenovo Y40-70/Y40-80/Y50-70/Y50-80/Y50-70 Touch/ Y50-80 Touch Figure 9. Removal steps of fan assembly and heat sink assembly (continued) Remove the screws 5.     Step 5 Screw (quantity) M2.0 × 6.5 mm, flat-head, nylok-coated (6) THERMAL MODULE(CPU) to MB (Y50-70/ Y50-80/Y50-70 Touch/Y50-80 Touch) Color Black Torque 2.5 kgf*cm Remove the heat sink assembly in the direction shown by arrow 6.  When installing: • Route the antenna cables along the cable guides. As you route the cables, make sure that they are not subjected to any tension. Tension could cause the cables to be damaged by the cable guides, or a wire to be broken. • Make sure that the connector is attached firmly. 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

57
Lenovo Y40-70/Y40-80/Y50-70/Y50-80/Y50-70 Touch/ Y50-80 Touch
Figure 9. Removal steps of fan assembly and heat sink assembly (continued)
Remove the screws
5
.
³
³
³
³
Step
Screw (quantity)
Color
Torque
5
M2.0 × 6.5 mm, flat-head, nylok-coated (6)
THERMAL MODULE(CPU) to MB (Y50-70/
Y50-80/Y50-70 Touch/Y50-80 Touch)
Black
2.5 kgf*cm
Remove the heat sink assembly in the direction shown by arrow
6
.
When installing:
Route the antenna cables along the cable guides. As you route the cables,
make sure that they are not subjected to any tension. Tension could cause
the cables to be damaged by the cable guides, or a wire to be broken.
Make sure that the connector is attached firmly.