Lexmark C532N Technical Reference - Page 275
Device Parameters for the Communication Device %TokenTalk%, %TokenTalkA%, %TokenTalkB%, %TokenTalkC
UPC - 734646258500
View all Lexmark C532N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 275 highlights
4-80 PostScript Table 4-11: PostScript Emulation Device Parameters (Continued) Key Type Definition Enabled boolean (Read-only) Supported values are: True False Filtering name Indicates if the input needs further filtering before the data can be correctly processed. Supported values are: InterpreterBased None HasNames boolean (Read-only) Always returns False. Interpreter name (Read-only) Supported values are: PostScript AutoSelect PCL PPDS On boolean Designates if the communication channel is On and able to receive and send data. Supported values are: True False Data is sent and processed. Data is lost. PCLSmartSwitch boolean Supported values are: True False PCL SmartSwitch is On. PCL SmartSwitch is Off. For more information, see "Using SmartSwitch" on page 2-1. PortLocation string (Read-only) Designates the physical location of the port related to the parameter set. Supported values are: Standard Port Option Slot 1, 2, and 3 (Model specific) PSSmartSwitch boolean Supported values are: True False PS SmartSwitch is set to On. PS SmartSwitch is set to Off. For more information, see "Using SmartSwitch" on page 4-1. Type name (Read-only) Always returns the value of /Communications. Device Parameters for the Communication Device %TokenTalk%, %TokenTalkA%, %TokenTalkB%, %TokenTalkC%, %TokenTalkD% (%TokenTalk_NV% and %TokenTalk_Pending% contain the same parameters) Address string (Read-only) Bridging name (Read-only) Adaptive