Lexmark C792 Forms and Bar Code Card Technical Reference Guide - Page 65
PCL specifications for composite bar codes, Field Name, Range, Default if not, specified, Definition
View all Lexmark C792 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
PCL specifications for composite bar codes Field Name Type Range Default (if not specified) Definition Symbology ID int - - Required 24600T specifies UPC-A 24601T specifies UPC-A+2 24602T specifies UPC-A+5 24610T specifies UPC-E 24611T specifies UPC-E+2 24612T specifies UPC-E+5 24620T specifies EAN-8 24621T specifies EAN-8+2 24622T specifies EAN-8+5 24630T specifies EAN-13 24631T specifies EAN-13+2 24632T specifies EAN-13+5 24710T specifies UCC-128 24810T specifies RSS-14 24811T specifies RSS-14 Truncated 24812T specifies RSS-14 Stacked 24814T specifies RSS-14 Limited 24815T specifies RSS-14 Expanded Module Height (of int the linear component) Dependent on the module height range of the linear component. Dependent on the default module height of the linear component. Corresponds to HP #v parameter Module Width (of int the linear component) Dependent on the module width range of the linear component. Dependent on the default module width of the linear component. Corresponds to the HP #b parameter The dimensions of the composite bar code may be varied in only two directions. • The module height of the linear component is varied using the V parameter. • The module width of the linear component is varied using the B parameter. Composite bar codes 62