Lexmark CX930 Printer Languages and Interfaces Technical Reference - Page 110
Device Parameters for the Communication Device %TokenTalk%, %TokenTalkA%, %TokenTalkB, TokenTalkC
View all Lexmark CX930 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
PostScript emulation 110 Key Type Definition PortLocation string (Read‑only) Designates the physical location of the port related to the parameter set. Supported values are: • Standard Port • Option Slot 1 • Option Slot 2 • Option Slot 3 • Option Slot 4 PSSmartSwitch Boolean Supported values are: • True-PS SmartSwitch is set to On. • False-PS SmartSwitch is set to Off. For more information, see "Selecting PostScript emulation" on page 91. Type name (Read‑only) Always returns the value of /Communications. Device Parameters for the Communication Device %TokenTalk%, %TokenTalkA%, %TokenTalkB%, %TokenTalkC%, %TokenTalkD% Address string (Read‑only). Bridging name (Read‑only) Adaptive. DelayedOutputClose Boolean Selects how the printer manages the port at the end of each print job. Supported values are: • True-An end‑of‑file message is not sent until the current job and all preceding jobs finish printing. • False-An end‑of‑file message is sent when a job finishes executing in the interpreter, whether the job has finished printing. Note: This value is set individually for each port. Enabled Boolean (Read‑only). Supported values are: • True • False Filtering name Indicates that the input needs further filtering before the data can be correctly processed. Supported values are: • InterpreterBased • None HasNames Interpreter Boolean name (Read‑only) Always returns False. (Read‑only). Supported values are: • PostScript • AutoSelect • PCL • PPDS