Lexmark MX6500e 6500e Forms and Bar Code Card Technical Reference Guide - Page 46
Field name, Range, Default value, Description, Bar/Space Width
View all Lexmark MX6500e 6500e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 46 highlights
Byte Field name 6-7 Bar Height 8 Bar/Space Width Units 9-10 Bar Width #1 (Code 128 bar 1, or Code 39 Narrow) 11-12 Space Width #1 (Code 128 space 1, or Code 39 Narrow) Type int int int int Range 150-600 (dec) 0=Default (1/600" units) 1=1/300" units 2=1/600" units 3=1/1200" units 5-27 (dec) 5-27 (dec) Default value Description 240 (dec) 00 F0 (hex) Optional Corresponds to HP #v parameter in the specified Bar Height units Note: Values that go beyond the defined range are appropriately clipped and set to the minimum and maximum values. The default HIBC bar height is 0.4 inches. If byte 5 is default 00 (600 dpi), then the bar height is 240 Bar Height Units, which is 00 F0 hex. 0 or 2 (dec) Optional 00 or 02 (hex) Specifies units for bar and space widths 6 (dec) 00 06 (hex) 6 (dec) 00 06 (hex) Optional Note: Values that go beyond the defined range are appropriately clipped and set to the minimum and maximum values. The default HIBC 128 bar 1 and HIBC 39 narrow bar widths are both 0.01 inches. If byte 5 is default 00 (600 dpi), then the bar width is 6, which is 00 06 hex. Optional Note: Values that go beyond the defined range are appropriately clipped and set to the minimum and maximum values. The default HIBC 128 space 1 and HIBC 39 narrow space widths are both 0.01 inches. If byte 5 is default 00 (600 dpi), then the space width is 6, which is 00 06 hex. One-dimensional bar codes 43