Lexmark Optra C710 Technical Reference - Page 123
Printer Unique Variables for PCL Emulation
View all Lexmark Optra C710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 123 highlights
3-46 PJL Printer Unique Variables for PCL Emulation The following variables are unique to your printer and are supported in PCL emulation only. The [command modifier:value] parameter should be specified as LPARM:PCL. For example: @PJL SET LPARM:PCL LBITMAPROUNDING=OFF[] To determine which variables your printer supports, see Table B-4: "Printer Unique Variables for PCL Emulation" on page B-12. Table 3-6: Printer Unique Variables for PCL Emulation Variable Function Selections LA4WIDTH A4 Width in millimeters 198, 203 LASSIGNFEEDER Tray Renumber Assign Envelope Feeder OFF, 0 to 199 Variable used with PJL SET or DEFAULT command. OFF, 0 to 199, NONE Variable used with PJL INQUIRE or DINQUIRE command. LASSIGNMANUALENVELOPE Tray Renumber Assign Manual Envelope OFF, 0 to 199 Variable used with PJL SET or DEFAULT command. OFF, 0 to 199, NONE Variable used with PJL INQUIRE or DINQUIRE command. LASSIGNMANUALPAPER Tray Renumber OFF, 0 to 199 Assign Manual Paper Variable used with PJL SET or DEFAULT command. OFF, 0 to 199, NONE Variable used with PJL INQUIRE or DINQUIRE command. LASSIGNMPFEEDER Tray Renumber Assign Multipurpose Feeder OFF, 0 to 199 Variable used with PJL SET or DEFAULT command. OFF, 0 to 199, NONE Variable used with PJL INQUIRE or DINQUIRE command. Factory Default 198 OFF OFF OFF OFF OFF OFF OFF OFF