Represents the Bar Widths in /Units.
UPC - 734646093835
View all Lexmark X652DE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
ITF-14 Key /Symbology Type name /Units name /Height int /Bars [int int] /Spaces [int int] Range Default value Description n/a n/a Required. /ITF14 /300ths /600ths /1200ths /600ths Optional. /Units is used in the calculations below. Min: 307 (dec) 01 33 (hex) Max: Ther is no maximum value, but larger bar codes may use up too much memory. • 756 (dec) or • 02 F4 (hex) Optional. Note: Values that go beyond the defined range will be appropriately clipped and set to the minimum and maximum values. Note: Bar Height does not include the bearer bars. Represents the Bar Height in /Units. Min: [12 27] (dec) Max: [24 72] (dec) Note: The range of values for Bar Width 2 is dependent on the value of Bar Width 1, where, Min = 2.25 x Bar Width 1 Max = 3 x Bar Width 1 • [12] (dec) or • [00 0C] (hex) Note: The default value for Bar Width 2 is dependent on the value of Bar Width 1, where Default = 2.50 x Bar Width 1 Optional. Note: Values that go beyond the defined range will be appropriately clipped and set to the minimum and maximum values. Represents the Bar Widths in /Units. Min: [12 27] (dec) Max: [24 72] (dec) Note: The range of values for Space Width 2 is dependent on the value of Space Width 1, where Min = 2.25 x Space Width 1 Max = 3 x Space Width 1 Space Width 1: • 12 (dec) or • 00 0C (hex) Optional. Note: Values that go beyond the defined range will be appropriately clipped and set to the minimum and maximum values. Represents the Space Widths in /Units. Two-dimensional bar codes 83