Lexmark X954 Forms and Bar Code Card Technical Reference Guide - Page 94

Arguments for MaxiCode bar code symbology

Page 94 highlights

Arguments for QR bar code symbology Key /Symbology Type name /Units name /Model name /ECC /Mode name name /ModuleSize integer Default Value - /600ths /Model2 /M /Mixed 10 Definition Required Identifies the bar code symbology (/QR) Optional Valid values are /300ths, /600ths, /1200ths Optional This determines the model of QR symbology used. Valid values are /Model1, /Model2 (default). Optional Sets the ECC level to /L, /M, /Q, /H Optional Sets the QR encoding mode to /Numeric, /Alphanumeric, /ECI, /Byte, /Kanji, /Mixed Optional Sets the size of the module element in /Units. The minimum value supported is 1. Arguments for MaxiCode bar code symbology Key /Symbology /Mode /QuietZone Range - 02-06 (dec) - Default value /MaxiCode 02 (dec) - Description Identifies the bar code symbology 02 = Structured carrier message with numeric postal code 03 = Structured carrier message with alphanumeric postal code 04 = Standard symbol with standard error correction 05 = Full symbol with enhanced error correction 06 = Reader program with standard error correction Sets the quiet zone in an array of two numbers Notes: Depending on the mode, the input data sent with the Transfer Bar Code Data command must follow these rules: • For all modes, the input data must start with a label-number and number-of-labels field. Both fields are one digit in length and are terminated with either a comma or Group Separator (GS, ASCII 29). • For modes 2 and 3, the postal code, country code, and class of service fields must follow the label fields. Each field must be terminated with either a comma or GS. Arguments for MaxiCode bar code symbology 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

Arguments for MaxiCode bar code symbology
91
Arguments for QR bar code symbology
Arguments for MaxiCode bar code symbology
Notes:
Depending on the mode, the input data sent with the Transfer Bar Code Data command must follow these
rules:
For all modes, the input data must start with a label-number and number-of-labels field. Both fields are one
digit in length and are terminated with either a comma or Group Separator (GS, ASCII 29).
For modes 2 and 3, the postal code, country code, and class of service fields must follow the label fields.
Each field must be terminated with either a comma or GS.
Key
Type
Default
Value
Definition
/Symbology
name
Required
Identifies the bar code symbology (/QR)
/Units
name
/600ths
Optional
Valid values are /300ths, /600ths, /1200ths
/Model
name
/Model2
Optional
This determines the model of QR symbology used. Valid values
are /Model1, /Model2 (default).
/ECC
name
/M
Optional
Sets the ECC level to /L, /M, /Q, /H
/Mode
name
/Mixed
Optional
Sets the QR encoding mode to /Numeric, /Alphanumeric, /ECI,
/Byte, /Kanji, /Mixed
/ModuleSize
integer
10
Optional
Sets the size of the module element in /Units. The minimum
value supported is 1.
Key
Range
Default
value
Description
/Symbology
/MaxiCode
Identifies the bar code symbology
/Mode
02–06 (dec)
02 (dec)
02 = Structured carrier message with numeric postal
code
03 = Structured carrier message with alphanumeric
postal
code
04 = Standard symbol with standard error correction
05 = Full symbol with enhanced error correction
06 = Reader program with standard error correction
/QuietZone
Sets the quiet zone in an array of two numbers