LiftMaster 8557 8557 Manual - Page 34

To Open the Door Manually, Maintenance, THE REMOTE CONTROL BATTERY

Page 34 highlights

To Open the Door Manually To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall. DISCONNECT THE TROLLEY 1 The door should be fully closed if possible. 2 Pull down on the emergency release handle. RECONNECT THE TROLLEY The lockout feature prevents the trolley from reconnecting automatically. 1 Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually as often as necessary. 2 To disengage the lockout feature, pull the handle straight down. The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote control. Maintenance EVERY MONTH • Manually operate door. If it is unbalanced or binding, call a trained door systems technician. • Check to be sure door opens and closes fully. Adjust if necessary, see page 24. • Test the safety reversal system. Adjust if necessary, see page 25. THE REMOTE CONTROL BATTERY EVERY YEAR • Oil door rollers, bearings and hinges. The garage door opener does not require additional lubrication. Do not grease the door tracks. • Test the battery and consider replacing the battery to ensure the garage door opener will operate during an electrical power outage, see page 26 to test the battery backup. EVERY TWO TO THREE YEARS • Use a rag to wipe away the existing grease from the garage door opener rail. Reapply a small layer of white lithium grease to the top and underside of the rail surface where the trolley slides. To prevent possible SERIOUS INJURY or DEATH: • NEVER allow small children near batteries. • If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn: • Replace ONLY with 3V2016 coin batteries. • DO NOT recharge, disassemble, heat above 212°F (100°C) or incinerate. NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modificationsof thistransceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expresslyapproved by the party responsible for compliance could void the user'sauthorityto operate the equipment. Thisdevice complieswith Part 15 of the FCC rulesand IC RSS-210. Operation issubject to the following two conditions: (1) thisdevice may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. ThisClassBdigitalapparatuscomplieswith Canadian ICES-003. To replace the batteries, remove the two screws and open the remote control housing. Push the battery out of the holder for removal. Insert replacement batteries positive side up (+). Replace the batteries with only 3V2016 coin cell batteries. Dispose of AVIS: Lesrèglesde la FCC et/ou d'Industrie Canada (IC) interdisent tout ajustement ou toute modification de ce récepteur. IL N'EXISTE AUCUNEPIÈCESUSCEPTIBLED'ÊTREENTRETENUEPAR L'UTILISATEUR. Tout changement ou toute modification non expressément approuvé par la partie responsablede la conformité peut avoir pour résultat d'annuler l'autorité de l'utilisateur de faire fonctionner l'équipement. Cet appareilest conforme auxdispositionsde la partie 15 du règlement de la FCC et de l'norme IC RSS-210. Son utilisation est assujettie auxdeuxconditoinssuivantes: (1) ce dispositif ne peut causer desinterférencesnuisibles, et (2) ce dispositif doit accepter toute interférence recue, ycomprisune interférence pouvant causer un fonctionnement non souhaité. Cet appareilnumerique de la classe Best conforme a la norme NMB-003 du Canada. old batteries properly. Batteries NOTICE NOTICE Screws (2) 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

34
To prevent possible SERIOUS INJURY or DEATH from a falling garage door:
If possible, use emergency release handle to disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly
and/or unexpectedly.
NEVER use emergency release handle unless garage doorway is clear of persons and
obstructions.
NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall.
DISCONNECT THE TROLLEY
1
The door should be fully closed if possible.
2
Pull down on the emergency release handle.
RECONNECT THE TROLLEY
The lockout feature prevents the trolley from reconnecting automatically.
1
Pull the emergency release handle down and back (toward the
opener). The door can then be raised and lowered manually as often
as necessary.
2
To disengage the lockout feature, pull the handle straight down.
The trolley will reconnect on the next UP or DOWN operation, either
manually or by using the door control or remote control.
NOTICE
NOTICE
Maintenance
EVERY MONTH
Manually operate door. If it is unbalanced or binding, call a trained door systems technician.
Check to be sure door opens and closes fully. Adjust if necessary, see page 24.
Test the safety reversal system. Adjust if necessary, see page 25.
EVERY YEAR
Oil door rollers, bearings and hinges. The garage door opener does not require additional
lubrication. Do not grease the door tracks.
Test the battery and consider replacing the battery to ensure the garage door opener will operate
during an electrical power outage, see page 26 to test the battery backup.
EVERY TWO TO THREE YEARS
Use a rag to wipe away the existing grease from the garage door opener rail. Reapply a small layer
of white lithium grease to the top and underside of the rail surface where the trolley slides.
NOTICE:To comply with FCC and/orIndustry Canada (IC) rules,adjustment or modificationsof thistransceiver are prohibited. THERE
ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expresslyapproved by the party responsible for compliance
couldvoidtheuser'sauthoritytooperatetheequipment.
Thisdevice complieswith Part 15 of the FCC rulesand IC RSS-210. Operation issubject to the following two conditions: (1)thisdevice may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesiredoperation.
ThisClassBdigitalapparatuscomplieswithCanadianICES-003.
AVIS:Lesrèglesde la FCCet/ou d’Industrie Canada (IC)interdisenttoutajustementou toute modification de ce récepteur.IL N’EXISTE
AUCUNEPIÈCESUSCEPTIBLED’ÊTREENTRETENUEPARL’UTILISATEUR.Toutchangementou toute modification non
expressémentapprouvéparlapartieresponsabledelaconformitépeutavoirpourrésultatd'annulerl'autoritédel'utilisateurdefaire
fonctionnerl'équipement.
Cet appareilest conforme auxdispositionsde la partie 15 du règlement de la FCC et de l'norme IC RSS-210. Son utilisation est assujettie
auxdeuxconditoinssuivantes:(1)cedispositifnepeutcauserdesinterférencesnuisibles,et(2)cedispositifdoitacceptertoute
interférencerecue,ycomprisuneinterférencepouvantcauserunfonctionnementnonsouhaité.
CetappareilnumeriquedelaclasseBestconformealanormeNMB-003duCanada.
THE REMOTE CONTROL BATTERY
To prevent possible SERIOUS INJURY or DEATH:
• NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
• Replace ONLY with 3V2016 coin batteries.
• DO NOT recharge, disassemble, heat above 212°F (100°C) or incinerate.
To replace the batteries, remove the two screws and open the remote
control housing. Push the battery out of the holder for removal. Insert
replacement batteries positive side up (+).
Replace the batteries with only 3V2016 coin cell batteries. Dispose of
old batteriesproperly.
Batteries
Screws (2)
To Open the Door Manually