LiftMaster CAPXLV CAPXLV Data Sheet - Page 2
LiftMaster CAPXLV Manual
View all LiftMaster CAPXLV manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
CONNECTED ACCESS PORTAL, HIGH CAPACITY WITH VIDEO CAPXLV SECTION 28 13 00 DIMENSIONS 14.000 2.500 .750 2X .750 .257 .386 4.478 4.273 TOP 18.000 2.500 .750 2X .750 .257 .386 CAPXLV 2X .386 4X 8.250 2X 7.402 2X 1.532 .000 2X 1.532 LEFT FRONT 10.920 RIGHT 2X 7.860 BACK RANGE 3X 1.282 3X 1.630 BOTTOM CAPXLV Feature Wired Wireless Wire type Range Power 120VAC to 24VDC transformer (from outlet to controller) x Wiegand accessory wiring x 2 wire (14 AWG) 2 wire (16 AWG) 2 wire (18 AWG) 7 wire (18-22 AWG) Up to 300 ft. Up to 200 ft. Up to 100 ft. Up to 500 ft. Relay output wiring x 2 wire (18-24 AWG) Up to 2500 ft. Exit Request (REX) x 2 wire (18-24 AWG) Up to 500 ft. Supervised input x 2 wire (18-24 AWG) Up to 500 ft. RJ-45 Internet Wireless link to LiftMaster® Operators Wi-Fi x CAT5 or better 8 strand (24 AWG) Up to 328 ft. x N/A Up to 1000 ft.* x N/A Up to 500 ft.** *When used with LiftMaster® operators with Security+ 2.0® Radio **When used with LiftMaster® Gate Operator mfg. after Nov. 2017 © 2020 The Chamberlain Group, Inc. All Rights Reserved. LiftMaster, the LiftMaster logo, are registered trademarks of the Chamberlain Group, Inc. LiftMaster.com LMARENDSCPXLV 8/20 4.750 4.750 5.625 4.750 3.875 2X 1.532 .000 2X 1.532 3.875 4.750 5.625 2X .257 2X .188 4X .310 1.630 2X .257