    Model CSL24U COMMERCIAL DC VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL • THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. • This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates. • This model is
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 2
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 3
    23 PROGRAMMING 25 REMOTE CONTROLS (NOT PROVIDED 25 LIFTMASTER INTERNET GATEWAY (NOT PROVIDED 26 ERASE ALL CODES 26 ERASE LIMITS 26 TO REMOVE AND ERASE MONITORED ENTRAPMENT PROTECTION DEVICES 26 OPERATION 27 GATE OPERATOR SETUP EXAMPLES 27 CONTROL BOARD OVERVIEW 28 RESET SWITCH
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 4
    A. The installer is required to install additional entrapment protection devices in each entrapment zone. IMPORTANT SAFETY INFORMATION To reduce the risk of INJURY or DEATH: • READ AND FOLLOW ALL INSTRUCTIONS. • NEVER let children operate or play with gate controls. Keep the remote control away
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 5
    • Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from the
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 6
    6 feet (1.83 m) above grade. An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator. A gate latch shall not be installed on an automatically operated gate. Protrusions shall not be permitted on any gate, refer to ASTM F2200 for Exceptions
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 7
    INTRODUCTION CARTON INVENTORY NOT SHOWN: Documentation Packet, Chain #41 - 30 feet, Eye Bolt Kit Operator Cover Warning Signs (2) and Warranty Card Battery 12 Vdc 7AH (2) Battery Tray Key (2) LiftMaster Monitored Retro-Reflective Photoelectric Sensor 5
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 8
    This model is intended for use in vehicular slide gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum Daily Cycle Rate Maximum
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 9
    or safety conditions encountered in your gate application. Install warning signs on both sides of the gate. Warning Signs Concrete Pads GATE Gate must be constructed and installed according to ASTM F2200 standards (refer to page 4). Gate must fit specifications of operator (refer to specifications
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 10
    Warning Sign Safety Catch Roller Edge Sensor Edge Sensor Photoelectric Sensors Operator DUAL GATE Earth Ground Rod Check national and local codes for proper depth Water Tight Conduit (Not provided) NOTE: Power and control wiring MUST be run in separate conduits. Warning Sign Safety Catch
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 11
    (46 cm) deep. • ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. TYPES OF INSTALLATIONS STANDARD INSTALLATION Operator REAR INSTALLATION Operator Gate Rail Stop (Inside Property) Gate Rail Stop Gate Rail Stop (Inside Property
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 12
    1 DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR Check the national and local building codes before installation. STANDARD INSTALLATION 1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad. 2. Install the electrical conduit. 3. Pour a concrete pad
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 13
    to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches. NOTE: An alternative to a concrete pad
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 14
    3 ATTACH THE CHAIN STANDARD INSTALLATION DO NOT run the operator until instructed. 1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position. 2. Manually close the gate and line up the
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 15
    NOT run the operator until instructed. NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction Information on page 4. 1. Move the back pulley to the bottom hole in the operator. 2. Manually close the gate and align the
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 16
    gate: • ALL gate operator systems REQUIRE two independent entrapment protection systems for each entrapment zone. • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 17
    . When an obstruction is sensed during gate closing the gate will open to the full open position and resets the Timer-to-Close. This input will be disregarded during gate opening. Close Photoelectric Sensors Close Edge CLOSE EDGE (2 Terminals) The CLOSE EDGE input is for edge sensor entrapment
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 18
    it with a single wire length. 1. Install the earth ground rod within 3 feet of the operator. 2. Run wire from the earth ground rod to the operator. NOTE: If the operator is not grounded properly the range of the remote controls will be reduced and the operator will be more susceptible to lightning
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 19
    INSTALLATION STEP 6 continued... POWER WIRING 240 VAC ONLY The accessory outlet is power from the main power source circuit breaker. 2. Run the AC power wires to the junction box on the operator. 3. Remove the junction box cover. 4. Connect the green wire to the earth ground rod and AC ground using
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 20
    INSTALLATION STEP 6 continued... AC POWER SWITCH The AC Power switch on the operator will turn the incoming 120/240 Vac power ON or OFF. The operator's AC Power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. AC Power Switch STEP 7 CONNECT BATTERIES
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 21
    integrated transformer. The batteries are for battery backup or solar installation. The 33AH application requires the 33AH wire harness (Model battery as shown. 5. Turn ON AC power to the operator. 6. Turn ON the AC power switch on the operator. 7. Reconnect the J15 plug to the control board. NOTE
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 22
    . The yellow NETWORK LED will light. 7. Press and release the CLOSE test button to assign this operator as network second. Both operators will beep and the yellow NETWORK LEDs will turn off indicating programming is successful. TO DEACTIVATE THE WIRELESS FEATURE: 1. Press and release the LEARN
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 23
    INSTALLATION STEP 8 continued... DUAL GATES ONLY WIRED DUAL GATES DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE gate to close before the other. The operator with the LOCK/BIPART DELAY switch ON will delay from the close limit when opening and be the first to close from the open limit. SLIDE GATE
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 24
    INSTALLATION STEP 9 INSTALL THE COVER The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up. The front cover and access door can be locked with the key. 1.
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 25
    limits will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. For slide gate applications the limits MUST be set at least four feet apart. 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 26
    encounters an obstruction during motion, the operator will automatically reverse direction of the gate for a short time and then stop the gate. After any adjustments are made, test the operator: 1. Open and close the gate with the test buttons, ensuring that the gate is stopping at the proper open
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 27
    , and STOP Three separate buttons as OPEN, CLOSE, and STOP DESCRIPTION PROGRAMMING STEPS Program a single button on the remote control for open only. The Timer-to-Close can be set to close the gate. 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). NOTE
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 28
    enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful. The status as shown by the LiftMaster Internet Gateway app will be either "open" or "closed". The gate operator can then be controlled through
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 29
    (Slide Gates Only) Attach alert signal (audible or visual alert system) to indicate if gate is manually tampered with by being pushed off of close to indicate if gate is manually tampered with by being pushed off of close limit. Use during servicing only to determine operator cycles. Typically not
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 30
    version, and codes. The operator type will display as "SL" followed by a "24" which indicates the operator type as CSL24U. The firmware version will show after the operator type, example "1.2". 12 BACKDRIVE Switch: Set to MANUAL will allow the gate to be manually pushed open or closed if there is
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 31
    shut off the alarm and reset the operator. After the operator is reset, normal functions will resume. E REMOTE CONTROL SINGLE BUTTON CONTROL (SBC) FUNCTIONALITY Once the remote control has been programmed the operator will operate as follows: When gate is in the closed position, activation of the
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 32
    external safeties and does not reset alarm condition). Used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open. • Opens a closing gate and holds open an open gate, if maintained, pauses Timer-to-Close at OPEN limit. SHADOW (2 Terminals
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 33
    for solar applications, the lock relay will only activate for four seconds near the close limit. Close at OPEN limit. Opens a closing gate and holds open an open gate (within line-of-sight). • CLOSE and COM: Closes an open gate. Hard close (maintained switch overrides external safeties and resets
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 34
    open approximately 15 seconds after AC power fail and remain OPEN until AC power is restored (enabling the Timer-to-Close). BATT: With loss of AC power, gate will remain in present position and operator is powered from batteries. 3 EXIT LOOP FAIL Switch: When set to OPEN, if the EXIT plug-in loop
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 35
    gate is manually tampered with by being pushed off of Energizes if gate is manually tampered with by being pushed close To determine the actual cycles that the gate operator has run (in thousands), set servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 36
    safeties and does not reset alarm condition) If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate and holds open an open gate. D Close Input (& common) (3-Button Control Station, 4 terminals total) Close command - closes an open gate. Soft close (maintained switch does not
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 37
    ONLY LiftMaster part 29-NP712 for replacement batteries. • SAVE THESE INSTRUCTIONS. • ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. MAINTENANCE CHART Disconnect all power (AC, solar, battery) to the operator before servicing
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 38
    TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. DIAGNOSTIC CODES NOTE: When cycling or disconnecting power (ac/
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 39
    TROUBLESHOOTING DIAGNOSTIC CODES continued... Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. LiftMaster System Installed System Informational External Entrapment Protection Inherent
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 40
    Inherent Entrapment Protection Code 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 80 81 82 83 91 92 93 94 99 Meaning Solution Minimum number of monitored entrapment protection devices (one) not installed. Review monitored entrapment protection device connections. CLOSE EYE/INTERRUPT held
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 41
    TROUBLESHOOTING CONTROL BOARD LEDS STATUS LEDS INPUT OFF POWER ON OFF state AC charger or Solar power available BATT GATE OFF MOVING ON The gate is stopped The gate is opening or closing MEDIUM BLINK (1 blink per second) Operator is in E1 (single entrapment) FASTEST BLINK (8 The operator
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 42
    set correct limits. a) Gate does not move to a limit position b) Gate is too difficult to move c) Limits are set too close (slide gate applications only) a) Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b) Gate must move easily and
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 43
    SOLUTIONS a) Review Exit loop reset the operator. a) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries On dual-gate system, incorrect gate opens first or closes
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 44
    or resetting. a) Accessory power protector active b) Defective control board Quick Close not working correctly. a) Quick Close setting accessory power draw c) Old batteries d) Solar panels are not getting enough sunlight Solar operator, insufficient standby time a) Insufficient panel wattage
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 45
    . We recommend LiftMaster low power draw accessories to minimize power draw, refer to accessory page. NOTE: Input solar power is 24 Vdc at 60 watts maximum. The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The gate operator is not supported in
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 46
    STEP 6 continued... SOLAR PANEL(S) SOLAR USAGE GUIDE APPENDIX Typical System Standby Battery Current Consumption (mA) System voltage Main board with no radios programmed One or more LiftMaster® remote controls programmed MyQ® device or wireless dual gate programmed Expansion board Per loop
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 47
    to 100 feet (30.48 m) from the operator using #16 AWG wire in any direction, including elevating it. • DO NOT install solar panel near potential shading or obstructions that will block the panel during any part of the day. • To optimize the system for winter operation the angle can be increased an
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 48
    STEP 6 continued... SOLAR PANEL(S) INSTALL THE SOLAR PANEL 1. Position solar bracket on mounting surface. Mark and drill holes. 2. Insert two bolts into the track located on the back of the solar panel(s). 3. Slide bolts in track away from bolt hole and align both bolts. 4. Secure solar panel(s) to
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 49
    OFF Bi-Part Delay: OFF (will open first & close last) Tandem Mode: OFF Synchronized Close: ON EXPANSION BOARD ACCESSORY PRIMARY OPERATOR Remote Controls Program remote controls 1 to 50 to the primary operator. LiftMaster Program to primary Internet Gateway operator. Garage and Gate Program to
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 50
    you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section. INITIAL LIMITS AND FORCE ADJUSTMENT For dual gate applications the limits will have to be set for each operator. The gate MUST be attached to the operator before setting the
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 51
    electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. WIRING DIAGRAM 49 For continued protection Red Red Black Piezo Alarm APS Encoder EXPANSION BOARD POWER TO MAIN BOARD OPEN CLOSE 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM SBC OPN CLS
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 52
    REPAIR PARTS Output Sprocket K15-41B17LKGH Gear Reducer Pulley and Motor Pulley K17-36530 Board with heat sink K1D8389-1CC Operator Cover with labels, keys, and lock assembly K77-37852 Chassis K73-34718-5 Electrical Box with junction box K77-36542 Reset Switch K180A0357 EMI Board with 120V
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 53
    key ring and fastening strip. Model 890MAX SECURITY+ 2.0® LEARNING REMOTE CONTROLS One button can control a gate operator and the other(s) can control garage door(s). It can also be programmed to Security+® or Security+ 2.0® code format. Models 892LT and 894LT KEYLESS ENTRY Enables homeowner to
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 54
    PLATE For post-mounting model CSL24U commercial slide operator (also SL3000 commercial slide operator). Posts not included. Model MPEL MISCELLANEOUS MAGNETIC GATE LOCK Outdoor magnetic lock, transformer, junction box, mounting plate and hardware. Not for use with Solar Applications. Must be powered
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 55
    is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect
  • LiftMaster CSL24U | CSL24U Installation Manual - Page 56
    01-37835C COLOR 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2015, LiftMaster - All Rights Reserved
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

COMMERCIAL DC
VEHICULAR SLIDE GATE OPERATOR
Model
CSL24U
INSTALLATION MANUAL
LiftMaster
845 Larch Avenue
Elmhurst, IL 60126-1196
THIS PRODUCT IS TO BE INSTALLED
AND SERVICED BY A TRAINED GATE
SYSTEMS TECHNICIAN ONLY.
This model is for use on vehicular
passage gates ONLY and not intended for
use on pedestrian passage gates.
This model is intended for use in Class I,
II, III and IV vehicular slide gate
applications.
Visit LiftMaster.com to locate a
professional installing dealer in your area.
This gate operator is compatible with
MyQ
®
and Security+ 2.0
®
accessories.