LiftMaster CSL24U CSL24U Installation Manual - Page 35

Auxiliary Relays, Cycle Count, Auxiliary Relay Wiring Example

Page 35 highlights

EXPANSION BOARD AUXILIARY RELAYS AUX RELAY 1 AND 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. Function of relay contact activation determined by switch settings. AUX RELAY SETTING SWITCH SETTINGS AUX RELAY 1 AUX RELAY 2 123 Off (no feature OFF OFF OFF selected) Relay always off. Use this Aux Relay setting to conserve battery power. Open Limit Switch OFF OFF ON Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate). Close Limit Switch OFF ON OFF Energizes when not at close limit. For an additional audible or visual display, connect an external light (low voltage). Gate Motion OFF ON ON Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an external buzzer or light (low voltage). Pre-Motion Delay Power Tamper Cycle Quantity Feedback* ON OFF OFF Energizes 3 seconds before gate motion and remains energized during Energizes 3 seconds before gate motion and remains gate motion. The onboard alarm will sound. For an additional audible energized during gate motion. For an additional audible or or visual display, connect an external buzzer or light (low voltage). visual display, connect an external buzzer or light (low voltage). ON ON OFF Energizes when AC power or solar power is present. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. Energizes when on battery power. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. ON OFF ON Energizes if gate is manually tampered with by being pushed off of Energizes if gate is manually tampered with by being pushed close limit. For an additional audible or visual display, connect an off of close limit. For an additional audible or visual display, external buzzer or light (low voltage). connect an external buzzer or light (low voltage). ON ON ON The 1, 2, and 3 LEDs will blink out the cycle count (cycle count is stored on the control board). See below. Not used. CYCLE COUNT * First, note the current Aux Relay switch positions. To determine the actual cycles that the gate operator has run (in thousands), set all three Aux Relay switches to the ON setting for Aux Relay 1. The Expansion Board's 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED blinking 1000's, 2 LED blinking 10,000's, 3 LED blinking 100,000's, and simultaneously all three LED's blink 1,000,000's (e.g. 1 LED blinks 3 times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is 163,000.). Cycle count displayed is between 1,000 and 9,999,000 cycles. After servicing, set Aux Relay switches back to their appropriate positions. Cycle count cannot be reset or changed. If under 1,000 cycles the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off. NOTE: The expansion board will flash the cycle count 3 times then all the LEDs will turn on solid for 10 seconds then turn off. AUXILIARY RELAY WIRING EXAMPLE SSHHAADDOW IINNTTEERRRUPPTT EEXXITIT OPEN CLOSE 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM SBC OPN CLS STP COM RED/GREEN LIGHT FUNCTIONALITY Red light wired to AUX RELAY 1. Green light wired to AUX RELAY 2. GATE STATE AUX RELAY 1 SWITCHES AUX RELAY 2 SWITCHES 1 OFF 2 OFF 3 OFF 1 ON 2 ON 3 ON CLOSED Red light OFF* Green light OFF OPENING OPEN CLOSING DEFINED MID STOP Red light ON/Flash Red light OFF Red light ON/Flash n/a Green light OFF Green light ON Green light OFF n/a UNDEFINED MID STOP Red light ON Green light OFF TIMER MORE THAN 5 SECONDS Red light OFF Green light ON TIMER LESS THAN 5 SECONDS Red light ON/Flash Green light OFF * For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON AUX RELAY WIRING EXAMPLE Aux Relay N.C. COM N.O. Class 2 Power Source (42 Vdc [34 Vac], + _ 5 A max) AUX Relay 2 N.C. Com AUX Relay 2 N.O. AUX Relay 1 N.C. Com AUX Relay 1 N.O. Warning Light AUX RELAY 1 AUX RELAY 2 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

33
EXPANSION BOARD
AUXILIARY RELAYS
SBC
OPN
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
SHADOW
INTERRUPT
EXIT
AUX RELAY WIRING EXAMPLE
AUX RELAY 2
AUX RELAY 1
Aux Relay
AUX Relay 2 N.C.
Com
Com
AUX Relay 1 N.C.
AUX Relay 2 N.O.
AUX Relay 1 N.O.
Class 2 Power Source
(42 Vdc [34 Vac],
5 A max)
Warning
Light
COM
N.C.
N.O.
+
_
CYCLE COUNT
*
First, note the current Aux Relay switch positions. To determine the
actual cycles that the gate operator has run (in thousands), set all three
Aux Relay switches to the ON setting for Aux Relay 1. The Expansion
Board’s 1, 2, and 3 LEDs will blink out the cycle count, with 1 LED
blinking 1000’s, 2 LED blinking 10,000’s, 3 LED blinking 100,000’s, and
simultaneously all three LED’s blink 1,000,000’s (e.g. 1 LED blinks 3
times, 2 LED blinks 6 times, and 3 LED blinks once. Cycle count is
163,000.). Cycle count displayed is between 1,000 and 9,999,000
cycles. After servicing, set Aux Relay switches back to their appropriate
positions. Cycle count cannot be reset or changed. If under 1,000
cycles the 1, 2, and 3 LEDs will turn on for 10 seconds, then turn off.
NOTE:
The expansion board will flash the cycle count 3 times then all the
LEDs will turn on solid for 10 seconds then turn off.
AUXILIARY RELAY WIRING EXAMPLE
AUX RELAY
SETTING
SWITCH
SETTINGS
AUX RELAY 1
AUX RELAY 2
1
2
3
Off (no feature
selected)
OFF
OFF
OFF
Relay always off. Use this Aux Relay setting to conserve battery power.
Open Limit Switch
OFF
OFF
ON
Energizes at open limit. Use with SAMS (Sequenced Access Management System, jointly with barrier gate).
Close Limit Switch
OFF
ON
OFF
Energizes when not at close limit. For an additional audible or visual display, connect an external light (low voltage).
Gate Motion
OFF
ON
ON
Energizes when motor is on (gate in motion). For an additional audible or visual display, connect an external buzzer or light (low voltage).
Pre-Motion Delay
ON
OFF
OFF
Energizes 3 seconds before gate motion and remains energized during
gate motion. The onboard alarm will sound. For an additional audible
or visual display, connect an external buzzer or light (low voltage).
Energizes 3 seconds before gate motion and remains
energized during gate motion. For an additional audible or
visual display, connect an external buzzer or light (low voltage).
Power
ON
ON
OFF
Energizes when AC power or solar power is present. There is
approximately a 10-12 second delay before relay cutoff, after AC
shutdown.
Energizes when on battery power. There is approximately
a 10-12 second delay before relay cutoff, after AC
shutdown.
Tamper
ON
OFF
ON
Energizes if gate is manually tampered with by being pushed off of
close limit. For an additional audible or visual display, connect an
external buzzer or light (low voltage).
Energizes if gate is manually tampered with by being pushed
off of close limit. For an additional audible or visual display,
connect an external buzzer or light (low voltage).
Cycle Quantity
Feedback*
ON
ON
ON
The 1, 2, and 3 LEDs will blink out the cycle count (cycle count is
stored on the control board). See below.
Not used.
AUX RELAY 1 AND 2
Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max
5 Amps) power sources only. Function of relay contact activation determined by switch settings.
RED
/
GREEN
LIGHT FUNCTIONALITY
Red light
wired to AUX RELAY 1
.
Green light
wired to AUX RELAY 2.
GATE STATE
AUX RELAY 1 SWITCHES
AUX RELAY 2 SWITCHES
1 OFF
2 OFF
3 OFF
1 ON
2 ON
3 ON
CLOSED
Red light OFF*
Green light OFF
OPENING
Red light ON/Flash
Green light OFF
OPEN
Red light OFF
Green light ON
CLOSING
Red light ON/Flash
Green light OFF
DEFINED MID STOP
n/a
n/a
UNDEFINED MID
STOP
Red light ON
Green light OFF
TIMER MORE THAN
5 SECONDS
Red light OFF
Green light ON
TIMER LESS THAN 5
SECONDS
Red light ON/Flash
Green light OFF
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON