LiftMaster CSL24VDC CSL24VDC Installation Manual

LiftMaster CSL24VDC Manual

LiftMaster CSL24VDC manual content summary:

  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 1
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 2
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 3
    32 TROUBLESHOOTING 33 ERROR CODES 33 CONTROL BOARD LEDS 36 TROUBLESHOOTING CHART 37 APPENDIX 40 TYPES OF INSTALLATIONS 40 DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR.........41 ATTACH THE CHAIN 41 SOLAR PANEL(S 42 SAMS WIRING WITH RELAYS NOT ENERGIZED 46 DUAL GATE SETTINGS
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 4
    SLIDE AND SWING GATE OPERATOR GATE cover both the opening and closing directions INSTRUCTIONS. • NEVER let children operate or play with gate controls. Keep the remote gate is not moving. • KEEP GATES PROPERLY MAINTAINED. Read the owner's manual. Have a qualified service person make repairs to gate
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 5
    • Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4. Install the gate operator only when: a. The operator is appropriate for the construction and the usage class of the gate. b. All openings of a horizontal slide gate are guarded or screened from the
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 6
    the roadway, (such as a gate support post) and the gate frame when the gate is in either the fully open position or the fully closed position, gate will enter a receiver guide, refer to ASTM F2200 for panel types. 3.2 The following provisions shall apply to Class IV vehicular horizontal slide gates
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 7
    INTRODUCTION CARTON INVENTORY NOT SHOWN: Documentation Packet, Chain #41 - 30 feet, Eye Bolt Kit Operator Cover Warning Signs (2) and Warranty Card Battery 12 Vdc 7AH (2) Battery Tray Key (2) 5
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 8
    OPERATOR SPECIFICATIONS This model is intended for use in vehicular slide gate applications: Usage Classification Main AC Supply System Operating Voltage Accessory Power Solar Power Max Maximum Gate Weight Minimum Gate Travel Distance Maximum Gate Travel Distance Maximum Gate Travel Speed Maximum
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 9
    SITE PREPARATION Check the national and local building codes BEFORE installation. CONDUIT & CONCRETE PAD Conduit must refer to specifications). VEHICLE LOOPS The vehicle loops allow the gate to stay open when vehicles are obstructing the gate path. Suggested for vehicles 14 feet (4.27 m) or
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 10
    Identify your installation type (refer to the Appendix in the back of the manual for more information). NOTE: One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists at either the opening or closing direction. Care shall be exercised to reduce the risk of
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 11
    • Place screen mesh 6 feet (1.8 m) high on the gate to prevent access through openings anywhere the gate may travel. • Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate. • Install Warning signs on EACH side of gate in PLAIN VIEW. Permanently secure each Warning sign
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 12
    61 cm) Post Mount 6" Above Ground Below the frost line. Check all national and local codes. 26" (66 cm) CONDUIT LOCATION MOUNTING FOOTPRINT 5-5/8" 1/2" 7" 2-1/4" 1-3/8" (Gate) 1-1/4" 3-1/2" min. 1-2" 2-3/4" (Conduit) 2.85" .63" 13" 23" 26" 11.9" 10.3" 10.4" 14.1" 4-1/2" 8" 15" (Pad) 24
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 13
    INSTALLATION STEP 3 ATTACH THE CHAIN Refer to the Appendix for rear installation step 3, page 41. DO NOT run the operator until instructed. 1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 14
    MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls. STEP 4 INSTALL ENTRAPMENT
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 15
    specific entrapment protection device manual for more information. These gate closing the gate will open to the full open position and resets the Timer-to-Close. This input will be disregarded during gate opening properly the range of the remote controls will be reduced and the operator will be
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 16
    that time the unit may be returned to service. • Disconnect power at the fuse box in accordance with national and local electrical codes. NOTE: The operator should be on Vac or a solar panel (not provided). Follow the directions according to your application. For dual gate applications, power will
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 17
    INSTALLATION STEP 6 continued... AC POWER SWITCH The AC Power switch on the operator will turn the incoming 120/240 Vac power ON or OFF. The operator's AC Power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. AC Power Switch STEP 7 CONNECT BATTERIES 7AH
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 18
    The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. The 33AH application requires the 33AH wire harness (Model K94-37236). NOTE: If 33AH batteries (2) are used, the battery tray underneath the heater will need to be
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 19
    Wired dual gate applications will have a longer battery standby time than wireless applications. WIRELESS DUAL GATES TO ACTIVATE primary operator. The yellow NETWORK LED will light. 4. Press and release the OPEN test button to assign this operator as network primary. 5. Press and release the
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 20
    close before the other. The operator with the LOCK/BIPART DELAY switch ON will delay from the close limit when opening and be the first to close from the open limit. SLIDE GATE APPLICATIONS: Not applicable, set to OFF. AC & BATT FAIL BACKDRIVE • SYNCHRONIZED CLOSE The BIPART DELAY is also used in
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 21
    of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up. The front cover and access door can be locked with the key. 1. Align the tabs on the rear cover with the
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 22
    will have to be set for each operator. The gate MUST be attached to the operator before setting the limits and force. For slide gate applications the limits MUST be set at least four feet apart. 1. Press and release the SET OPEN and SET CLOSE buttons simultaneously to enter limit setting mode
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 23
    injury to a person. The force setting is the same for both the open and close gate directions. 1. Open and close the gate with the TEST BUTTONS. 2. If the gate stops or reverses before reaching the fully open or closed position, increase the force by turning the force control slightly clockwise
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 24
    gate. 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). 2. Press the OPEN button. 3. Press the remote control button that you would like to program. Program one remote digital device, pursuant to part 15 of the FCC rules with the instructions, may cause
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 25
    beep if programming is successful. The status as shown by the LiftMaster Internet Gateway app will be either "open" or "closed". The gate operator can then be controlled through the LiftMaster Internet Gateway app. ERASE ALL CODES 1. Press and release the LEARN button (operator will beep and green
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 26
    Aux Relay Out - Tamper (Slide Gates Only) Cycle Quantity Feedback Fire Dept Open input Heater Accessory (Model HTR) RESIDENTIAL COMMERCIAL/GENERAL COMMERCIAL indicate if gate is manually tampered with by being pushed off of close limit. Use during servicing only to Use during servicing only to
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 27
    version, and error codes. The operator type will display as "SL" followed by a "24" which indicates the operator type as CSL24VDC. The firmware version will show after the operator type, example "1.2". 12 BACKDRIVE Switch: Set to MANUAL will allow the gate to be manually pushed open or closed if
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 28
    button will open the gate. During the open cycle another activation of the remote control will stop the gate and the next activation of the remote control will close the gate. When the gate is in the open position, activation of the remote control button will close the gate. If the remote control is
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 29
    for photoelectric sensor vehicle detection for the close direction. When an obstruction is sensed during gate closing the gate will open to the full open position. This input will be disregarded during gate opening and resets the Timer-to-Close. CLOSE EDGE (2 Terminals) The CLOSE EDGE input is for
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 30
    safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate and holds open an open gate (within line-of-sight). • CLOSE and COM: Closes an open gate. Hard close (maintained switch overrides external safeties and resets alarm condition within
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 31
    in present position and operator is powered from batteries. 3 EXIT LOOP FAIL Switch: When set to OPEN, if the EXIT plug-in loop detector (Model LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared. When set to CLOSE, then plug-in EXIT loop detector faults are
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 32
    ) Open Limit solar power is present. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. Energizes when on battery power. There is approximately a 10-12 second delay before relay cutoff, after AC shutdown. ON OFF ON Energizes if gate is manually After servicing, set
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 33
    F Exit Loop Input (2 terminals) Loop wire connection for plug-in loop detector when loop is inside secured area near gate. Open command - opens a closed gate. Soft open (maintained switch does not override external safeties and does not reset alarm condition) If maintained, pauses Timer-to-Close at
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 34
    ONLY LiftMaster part 29-NP712 for replacement batteries. • SAVE THESE INSTRUCTIONS. • ALWAYS wear protective gloves and eye protection when changing the battery or working around the battery compartment. MAINTENANCE CHART Disconnect all power (AC, solar, battery) to the operator before servicing
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 35
    TROUBLESHOOTING To protect against fire and electrocution: • DISCONNECT power (AC or solar and battery) BEFORE installing or servicing operator. For continued protection against fire: • Replace ONLY with fuse of same type and rating. ERROR CODES NOTE: When cycling or disconnecting power (ac/dc)
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 36
    - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. Wireless edge battery low Replace batteries in wireless edge. Battery shorted Check battery harness for short to chassis Run-Distance Error Gate
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 37
    TROUBLESHOOTING ERROR CODES continued... Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs, then disappear. Error Code 66 67 68 69 70 71 72 73 74 75 80 81 82 83 91 93 99 Meaning OPEN EYE/EDGE
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 38
    MOVING ON The gate is stopped The gate is opening or closing MEDIUM BLINK (1 Operator is in E1 (single blink per second) entrapment) FASTEST BLINK (8 The operator is in E2 (double blinks per second) entrapment) BATT LOW OFF ON No battery error Battery low BLINK (1 blink per second) Battery
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 39
    TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a) No power to control board a) Check AC and battery power run and error code b) Open fuse b) Check fuses display not on. c) If on battery power only, low or dead batteries c) Charge batteries by AC or solar
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 40
    then running on batteries and battery voltage must be 23.0 Vdc or higher. Charge batteries by AC or solar power or replace batteries On dual-gate system, incorrect gate opens first or closes first. Alarm beeps when running. a) Incorrect Bipart switch setting a) Expansion board setting b) Constant
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 41
    TROUBLESHOOTING TROUBLESHOOTING CHART continued... SYMPTOM Solenoid lock not working correctly. expansion board. a) Add more solar panels b) Reduce the accessory power draw by using LiftMaster low power accessories c) Replace batteries d) Relocate the solar panels away from obstructions (trees
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 42
    TYPES OF INSTALLATIONS STANDARD INSTALLATION The illustration is an example of a standard installation. APPENDIX Gate Rail Stop (Inside Property) ! Gate Rail Stop REAR INSTALLATION The illustration is an example of a rear installation. Gate Rail Stop (Inside Property) ! Gate Rail Stop 40
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 43
    of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches. 2. Lay out the concrete pad. REAR INSTALLATION 4" (10 cm) 26" (66 cm) 24" (61 cm) STEP 3 ATTACH THE CHAIN REAR INSTALLATION ONLY DO NOT run the operator until instructed. NOTE
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 44
    cleaned on a regular basis for best performance to ensure proper operation. SOLAR USAGE GUIDE The CSL24VDC has best in class solar performance due to highly efficient electronics that draw very little power while the gate is not in use (standby). Typical System Standby Battery Current Consumption
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 45
    STEP 6 continued... SOLAR PANEL(S) SOLAR USAGE GUIDE APPENDIX SOLAR ZONES 3 NOT AVAILABLE 2 3 1 2 1 NOT AVAILABLE 1 10W SOLAR PANEL 20W SOLAR PANEL 40W SOLAR PANEL 60W SOLAR PANEL BATTERY CURRENT DRAW (mA) 5 15 20 40 60 5 15 20 50 100 5 15 20 100 200 5 15 20 100 250 SOLAR GATE CYCLES PER
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 46
    (30.48 m) from the operator using #16 AWG wire in any direction, including elevating it. • DO NOT install solar panel near potential shading or obstructions that will block the panel during any part of the day. • To optimize the system for winter operation the angle can be increased an additional 15
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 47
    solar panel(s). 3. Slide bolts in track away from bolt hole and align both bolts. 4. Secure solar panel(s) to solar bracket using two washered nuts. 5. Secure solar Dual Gate section (if applicable) or proceed to the Adjustment section. 33AH Batteries - +- + J15 Plug (new wire harness, Model K94-
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 48
    OPERATOR OFF Bi-Part Delay: OFF (will open first and close last) Tandem Mode: OFF Synchronized Close: ON ACCESSORY PRIMARY OPERATOR Remote Controls Program remote controls 1 to 50 to the primary operator. LiftMaster Program to primary Internet Gateway operator. Garage and Gate Program to
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 49
    is in the desired close position, press and release the STOP button on the remote control. 7. Press and release the CLOSE button on the remote control again to set the close limit. 8. Cycle the gate open and close. This automatically sets the force. When limits are set properly the operator will
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 50
    servicing operator. Field Wiring Edge N.O. COM N.C. SLIDE WIRING DIAGRAM 47-36242-10-E ECN: 15400 Reference: 06-36230D 5/10/12 N.O. COM N.C. LOCK Solenoid Lock (Optional) (not provided) LOCK Two 12V Solar FILTER/SURGE PROTECTION BOARD SHADOW INTERUPT EXIT OPEN CLOSE 1 EYE ONLY 2 EYE/ EDGE
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 51
    K77-36542 17 K180A0357 18 K94-35152 19 K75-36260 20 Q118 21 K13-34729 22 Q013 23 29-NP712 24 K10-34758-2 INDIVIDUAL PARTS DESCRIPTION Chassis Operator Cover with labels, keys, and lock assembly APS Encoder, 24V Timing Belt, 3M Gear Reducer Pulley and Motor Pulley Output Sprocket
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 52
    6 22 7 15 REPAIR PARTS 5 4 23 9 3 18 10 8 11 24 12 1 16 17 13 21 14 2 19 20 50
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 53
    your authorized LiftMaster dealer for additional details and options. 3-BUTTON REMOTE CONTROL The 3-button remote control can be programmed to control the operator. Includes visor clip. Model 893MAX MISCELLANEOUS POST-MOUNTING PLATE For post-mounting model CSL24VDC commercial slide operator (also
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 54
    °C) for extended periods of time. Model HTR LIFTMASTER® INTERNET GATEWAY Internet enabled accessory which connects to the computer and allows you to monitor and control gate operators and lighting accessories enabled by MyQ® technology. Model 828LM BATTERIES Gate access system batteries replace or
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 55
    this product. Then send this product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product returned for warranty repair
  • LiftMaster CSL24VDC | CSL24VDC Installation Manual - Page 56
    01-37011C 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2013, LiftMaster - All Rights Reserved
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56