CONTROL CONNECTION DIAGRAM IMPORTANT NOTES: 1. The 3-Button Control Station provided must be connected for operation. 2. If a STOP button is not used, a jumper must be placed between terminals 3 and 4. ATTENTION ELECTRICIAN: USE 16 GAUGE OR HEAVIER WIRE FOR ALL CONTROL CIRCUIT WIRING. 3. Auxiliary control equipment may be any normally open two wire device such as pullswitch, single button control station, loop detector, card key or such device. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 1234 2 OR MORE 1234 KEY LOCKOUT 1234 Open Close Stop Open Close Stop Open Close Stop Open Close Stop Keyswitch ALL CONTROL WIRING TYPES ALL CONTROL WIRING TYPES 2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER STANDARD 124 SEE NOTE #2 2 OR MORE 124 SEE NOTE #2 ALL CONTROL WIRING TYPES 1 BUTTON STATION OR ANY AUXILIARY DEVICE 37 SEE NOTES #2 AND #3 Open Close ALL CONTROL WIRING TYPES Open Open Close Close ALL CONTROL WIRING TYPES Open / Close B2 OR T1 WIRING TYPES ONLY SENSING DEVICE TO REVERSE OR STOP EXTERNAL INTERLOCK 3 10 Sensing Device ALL CONTROL WIRING TYPES Remove Jumper When Interlock is Used 4 5 4 5 One 2 or More ALL CONTROL WIRING TYPES 01-16492C © 2008, The Chamberlain Group, Inc. All Rights Reserved

  • 1
  • 2
  • 3
  • 4

© 2008, The Chamberlain Group, Inc.
01-16492C
All Rights Reserved
CONTROL CONNECTION DIAGRAM
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MORE
KEY LOCKOUT
1
2
3
4
Stop
Close
Open
Stop
Close
Open
1
2
3
4
Stop
Close
Open
2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
STANDARD
1
2
4
Close
Open
ALL CONTROL WIRING TYPES
2 OR MORE
1
2
4
Close
Open
Close
Open
Open / Close
3
7
1 BUTTON STATION OR
ANY AUXILIARY DEVICE
EXTERNAL INTERLOCK
SENSING DEVICE TO REVERSE OR STOP
3
10
4
5
4
5
Remove Jumper
When Interlock is Used
One
2 or More
STANDARD
1
2
3
4
Stop
Close
Open
IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between
terminals 3 and 4.
3. Auxiliary control equipment may be any normally open two wire device
such as pullswitch, single button control station, loop detector, card key or such device.
Keyswitch
Sensing Device
ALL CONTROL WIRING TYPES
B2 OR T1
WIRING TYPES ONLY
ALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
ALL CONTROL WIRING TYPES
ATTENTION ELECTRICIAN:
USE 16 GAUGE OR HEAVIER WIRE
FOR ALL CONTROL CIRCUIT WIRING.
SEE NOTE #2
SEE NOTE #2
SEE NOTES
#2 AND #3