APPLICATION REQUIREMENTS This modification is available to models H and J Logic operators. FUNCTIONS This modification stops the operator from running when extra tension is sensed on the door from the mechanical door lock, obstruction, or extensive binding. OPERATION When the lock sensor senses an excessive load while running the open cycle from the close limit, the lock sensor will stop the operator. Press the close button and run the operator until it shuts off (to unlock the door when the load is removed). ADDENDUM LOCK SENSOR Models DH, DJ, and DHJ NOTE: Refer to lock sensor addendum for adjustment. For all other installation instructions refer to owner's manual provided with operator. LOCK SENSOR ADJUSTMENT FINE ADJUSTMENT • To increase opening force, tighten the wing nut. • To decrease opening force, loosen the wing nut. COURSE ADJUSTMENT (IF REQUIRED) 1. Release spring pressure on pivot arm. 2. Loosen but do not remove two mounting screws. 3. Fully tension final reduction chain and rotate lock sensor until switch is in activation mode. 4. Tighten mounting screws (2) to secure lock sensor position. 5. Repeat fine adjustments. WARNING Moving parts may cause SERIOUS INJURY. Keep hands CAUTION CLEAR of sprockets, chains, and other moving parts when making adjustments. FiFnianlalRReedduucction CChhaainin CChhaaininIdIdleler rSSprporcokcekt et mmuusstt eennggaaggeetotpopsidseide ooff rreedduucctitoionncchhaiani.n. LLoocckk SSennssoorrAAsssememblbyly MMouounntitninggSSccrreewwss LLoocckkSSenesnosroSrwSiwtcihtch AVERTISSEMENT ((hheeldldtotonnoormrmalalyllcylocsloeds)e.d). ATTENTION TTooadajdujsutsotpoepneinnginfogrcfoertcigehten otriglohotseennoardljousotsmeenntaodnjuwstinmgennutt aoccnowrdiinnglyn.ut accordingly. 01-31376C © 2010, The Chamberlain Group, Inc. All Rights Reserved

  • 1

APPLICATION REQUIREMENTS
This modification is available to models H and J Logic operators.
FUNCTIONS
This modification stops the operator from running when extra
tension is sensed on the door from the mechanical door lock,
obstruction, or extensive binding.
OPERATION
When the lock sensor senses an excessive load while running the
open cycle from the close limit, the lock sensor will stop the
operator. Press the close button and run the operator until it
shuts off (to unlock the door when the load is removed).
NOTE:
Refer to lock sensor addendum for adjustment. For all
other installation instructions refer to owner’s manual provided
with operator.
ADDENDUM
LOCK SENSOR
Models DH, DJ, and DHJ
FINE ADJUSTMENT
To increase opening force, tighten the wing nut.
To decrease opening force, loosen the wing nut.
COURSE ADJUSTMENT (IF REQUIRED)
1. Release spring pressure on pivot arm.
2. Loosen but do not remove two mounting screws.
3. Fully tension final reduction chain and rotate lock sensor until
switch is in activation mode.
4. Tighten mounting screws (2) to secure lock sensor position.
5. Repeat fine adjustments.
LOCK SENSOR ADJUSTMENT
Moving parts may cause SERIOUS INJURY. Keep hands
CLEAR of sprockets, chains, and other moving parts when
making adjustments.
WARNING
WARNING
© 2010, The Chamberlain Group, Inc.
01-31376C
All Rights Reserved
Final Reduction Chain
Chain Idler Sprocket
must engage top side
of reduction chain.
Lock Sensor Switch
(held to normally closed).
To adjust opening force tighten
or loosen adjustment on wing nut
accordingly.
Mounting Screws