LiftMaster EWC485 EWC485 Manual - Page 1

LiftMaster EWC485 Manual

Page 1 highlights

EWC485 Range Test 1 The Elite Processor MUST have this sticker to use the wireless communicator. Firmware version 6.11 or later. WIRELESS communicator Compatible 2 Screw antennas on TIGHT. WcoCImoRm mEupLnaiEtciabStloSer Loose antennas will affect the signal strength! 3 Unlock the units and open doors. 4 Set both units to TEST MODE. ONLY test 2 units at a time, turn ALL other units OFF! 5 Set one unit to LOCAL connection and the other to REMOTE connection. The "LOCAL connection" unit is near the telephone entry system. 6 Temporarily stick the supplied battery packs on the outside of each unit with the double stick tape. Feed the wires through an existing hole on back of the unit. It is VERY important that BOTH battery packs produce 12VDC, weak batteries will produce undependable test results. 7 Both units must be set to the same FACILITY FREQUENCY. If they are not the same, follow Step 55 on the manual to set the frequencies on both units. 8 Connect the battery wires to the removable power connector. When BOTH units have been powered up, a CONTINUOUS tone will be heard from both units indicating strong signals are being transmitted and received. 9 Close and lock the units placing the LOCAL unit in its final position near the telephone entry system. Recommend minimum 8 feet above ground. 10 Take the REMOTE unit to the desired remote access point and place it in its final position. Part Number 41A6082 A continuous tone should be heard indicating that the range is OK. The units can now be permanently installed in their current positions. Use the supplied transformer for permanent power. Discard battery pack. 11 Set the units back to OPERATING MODE. Stronger Signal Less Interference More Interference Weak Signal If a continuous tone is NOT heard during the range test: Make sure the antennas are screwed on tight. Try moving the remote unit 15-20 feet in several directions, away from metal surfaces or any obstructions. Try moving the local unit 15-20 feet in several directions. Try raising the units up, above the rooftops if necessary to clear any obstacles. The higher the units, the less interference they will encounter. Keep antenna clear from metal surfaces or any obstructions that can weaken the signal strength. Test the battery packs with a voltmeter for 12VDC. Weak batteries will produce undependable test results. Try changing the FACILITY FREQUENCY of the units. Follow Step 555 on the manual. Both units MUST be set to the same frequency. If a continuous tone is not achieved after all previous suggestions have been tried, call for toll free technical support: 1-800-582-2806 114A2969 4 5 © 2004 The Chamberlain Group, Inc. All Rights Reserved ® ™ 845 Larch Avenue Elmhurst, Illinois 60126-1196

  • 1
  • 2

Screw antennas on
TIGHT
.
Loose antennas will affect the signal strength!
Unlock the units and open doors.
Set both units to
TEST MODE
.
ONLY
test 2 units at a time, turn ALL other units OFF!
Set one unit to
LOCAL connection
and the other to
REMOTE connection
. The
“LOCAL
connection” unit
is near the telephone entry system.
Temporarily stick the supplied battery packs on the outside of each unit with the double stick
tape. Feed the wires through an existing hole on back of the unit. It is
VERY
important that
BOTH
battery packs produce 12VDC, weak batteries will produce undependable test results.
Both units
must
be set to the same
FACILITY FREQUENCY
. If they are not the same,
follow
Step
5
on the manual to set the frequencies on both units.
Connect the battery wires to the removable power connector. When
BOTH
units have been powered up, a
CONTINUOUS tone
will be heard from both
units indicating strong signals are being transmitted
and received.
Close and lock the units placing the
LOCAL
unit in
its final position near the telephone entry system.
Recommend minimum 8 feet above ground.
Take the
REMOTE
unit to the desired remote access
point and place it in its final position.
A continuous tone should be heard indicating that the range is OK.
The units can now be
permanently installed
in their current
positions.
Use the supplied transformer for permanent power. Discard battery pack.
Set the units back to
OPERATING MODE
.
845 Larch Avenue Elmhurst, Illinois 60126-1196
EWC485 Range Test
2
1
3
4
5
6
7
8
9
11
10
4
5
If
a continuous tone is not achieved after all previous suggestions have been tried,
call for toll free technical support:
1-800-582-2806
Stronger Signal
Less Interference
More Interference
Weak Signal
5
114A2969
Part Number 41A6082
WIRELESS
Compatible
WIRELESS
communicator
Compatible
The Elite Processor MUST have this
sticker to use the wireless communicator.
Firmware version 6.11 or later.
Make sure
the antennas are screwed on tight.
Try
moving the remote unit 15-20 feet in several directions, away from metal surfaces or any obstructions.
Try
moving the local unit 15-20 feet in several directions.
Try
raising the units up, above the rooftops if necessary to clear any obstacles. The higher the units, the
less interference they will encounter. Keep antenna clear from metal surfaces or any obstructions that can
weaken the signal strength.
Test
the battery packs with a voltmeter for 12VDC. Weak batteries will produce undependable test results.
Try
changing the
FACILITY FREQUENCY
of the units. Follow
Step
55
on the manual. Both units
MUST
be
set to the same frequency.
If a continuous tone is
NOT heard
during the range test:
5
© 2004 The Chamberlain Group, Inc.
All Rights Reserved
®