LiftMaster GH GH LOGIC VERSION 1 Manual - Page 6

Entrapment Protection Accessories, Limit Switch Adjustment - door opener

Page 6 highlights

ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) SENSING EDGES All types of sensing edges with an isolated normally open (N.O.) output are compatible with your operator. This includes pneumatic and electric edges. If your door does not have a bottom sensing edge and you wish to purchase one, contact the supplier of your operator. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. Refer to the steps below Important Notes: a) Proceed with Limit Switch Adjustments before making any sensing edge wiring connections to operator as described below. b) Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. IT IS STRONGLY RECOMMENDED THAT A SENSING EDGE OR OTHER ENTRAPMENT PROTECTION DEVICE BE USED IN CONJUNCTION WITH THIS OPERATOR. TAKE-UP REEL: Take-up reel should be installed 12" above the top of the door. COIL CORD: Connect operator end of coil cord to junction box (not supplied) fastened to the wall approximately halfway up the door opening. LIMIT SWITCH ADJUSTMENT MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. 1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. 2. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. 3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. 4. Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. If other problems persist, call our toll-free number for assistance - 1-800-528-2806. OPEN Limit Switch CLOSE Limit Switch Actuator SAFETY (Aux. Close) Limit Switch 6 Retaining Plate

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

6
TO AVOID SERIOUS PERSONAL INJURY OR DEATH
FROM ELECTROCUTION, DISCONNECT ELECTRIC
POWER BEFORE MANUALLY MOVING LIMIT NUTS.
WARNING
LIMIT SWITCH ADJUSTMENT
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE
PROCEEDING WITH ADJUSTMENTS.
SENSING EDGES
All types of sensing edges with an isolated normally
open (N.O.) output are compatible with your
operator. This includes pneumatic and electric
edges.
If your door does not have a bottom sensing
edge and you wish to purchase one, contact the
supplier of your operator.
If not pre-installed by the door manufacturer, mount
the sensing edge on the door according to the
instructions provided with the edge.
The sensing
edge may be electrically connected by either coiled
cord or take-up reel. Refer to the steps below
Important Notes:
a)
Proceed with Limit Switch Adjustments before
making any sensing edge wiring connections to
operator as described below.
b)
Electrician must hardwire the junction box to the
operator electrical box in accordance with local
codes.
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL)
IT IS STRONGLY RECOMMENDED THAT A
SENSING EDGE OR OTHER ENTRAPMENT
PROTECTION
DEVICE
BE
USED
IN
CONJUNCTION WITH THIS OPERATOR.
TAKE-UP REEL:
Take-up reel should be installed
12" above the top of the door.
COIL CORD:
Connect operator end of coil cord to
junction box (not supplied) fastened to the wall
approximately halfway up the door opening.
If other problems persist, call our toll-free number for
assistance - 1-800-528-2806.
Retaining Plate
CLOSE
Limit Switch
SAFETY
(Aux. Close) Limit Switch
OPEN
Limit Switch
1.
To adjust limit nuts depress retaining plate to allow
nut to spin freely.
After adjustment, release plate
and ensure it seats fully in slots of both nuts.
2.
To
increase
door travel, spin nut
away
from
actuator. To
decrease
door travel, spin limit nut
toward
actuator.
3.
Adjust open limit nut so that door will stop in open
position with the bottom of the door even with top
of door opening.
4.
Repeat Steps 1 and 2 for close cycle. Adjust close
limit nut so that actuator is engaged as door fully
seats at the floor.
Actuator