INTRODUCTION Congratulations on purchasing a quality, LiftMaster Medium Duty existing 315 MHz product line as well as a Timer To Close (TTC) Commercial Door Operator. Your new operator is capable of feature that can be enabled when LiftMaster Commercial Protector operating up to 12 cycles per hour or 50 cycles per day. It is System® is installed and aligned properly. equipped with a built in radio receiver that is compatible with our WARNING BASIC PROGRAMMING DETERMINE THE WIRING TYPE The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C2 wiring type (factory default). Some wiring types will require an optional safety device. Refer to the following descriptions of wiring types, requirements and programming. NOTE: 1. The LED on the logic board will blink once when in C2 and twice when in B2. 2. The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. If the Monitored Safety Device is removed, the operator will go into a Restricted Close mode**. Turn power OFF and ON to reset wiring type. ** Restricted close mode requires a constant pressure close command. The operator will begin closing after a 5 second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit. C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE A (Factory Default) • Momentary contact to open and stop with constant pressure to close. • Open override that reverses when closing by any opening device. • Wiring for safety device to reverse. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) • Timer to Close (TTC) feature not available. NON-MONITORED SAFETY DEVICE CAUTION To prevent possible SEVERE INJURY or DEATH, install reversing sensors when: • The radio is used. • The 3-button control station is out of sight of the door. • Or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. AVERTISSEMENT ATTENTION B C2 WIRING TYPE WITH MONITORED SAFETY DEVICE • Momentary contact to open and stop with constant pressure to close. • Open override that reverses when closing by any opening device. • Wiring for safety device to reverse. NOTE: The operator will automatically convert to B2 wiring (option D) when Monitored Safety Device is installed. (See accessories page for Monitored Safety Devices) • Timer to Close (TTC) feature not available. MONITORED SAFETY DEVICE C31 C31 Sensing Edge RESET TO C2 WIRING TYPE (Factory Default) Remove any monitored safety devices. Disconnect then reconnect power to the operator. Press and hold the LEARN and STOP buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board 014A1030 J4 C32 TP1 C20 R25 C9 C21 U1 D7 D5 U4 D6 D4 AAUUX AANNTT J2 L5 ^^^^ R27 TTC 1 C18 D14 LEARN STOP CLOSE OPEN LED 2 3 4 5 6 7 K2 LT C29 R24 P1 D9 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LEARN STOP CLOSE OPEN LEDD14 1 2 3 4 5 6 7 ADVERTENCIA PRECAUCIÓN TO PROGRAM Photo Eye Press and hold the LEARN and CLOSE buttons until the LED goes out (approximately 3 seconds). Electrical Box Logic Board 014A1030 J4 C32 TP1 C20 R25 C9 C21 U1 D7 D5 U4 D6 D4 AAUUX AANNTT J2 L5 ^^^^ R27 TTC 1 C18 D14 LEARN STOP CLOSE OPEN LED 2 3 4 5 6 7 K2 LT C29 R24 P1 D9 LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN LEARN STOP CLOSE OPEN LEDD14 1 2 3 4 5 6 7 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Congratulations on purchasing a quality, LiftMaster Medium Duty
Commercial Door Operator. Your new operator is capable of
operating up to 12 cycles per hour or 50 cycles per day. It is
equipped with a built in radio receiver that is compatible with our
existing 315 MHz product line as well as a Timer To Close (TTC)
feature that can be enabled when LiftMaster Commercial Protector
System
®
is installed and aligned properly.
DETERMINE THE WIRING TYPE
The functionality of this operator is based on the wiring type. The
operator is shipped from the factory in standard C2 wiring type
(factory default). Some wiring types will require an optional safety
device. Refer to the following descriptions of wiring types,
requirements and programming.
NOTE:
1.
The LED on the logic board will blink once when in C2
and twice when in B2.
2.
The operator will automatically convert to B2 wiring (option
D) when Monitored Safety Device is installed. If the
Monitored Safety Device is removed, the operator will go
into a Restricted Close mode**. Turn power OFF and ON to
reset wiring type.
**
Restricted close mode requires a constant pressure close
command. The operator will begin closing after a 5 second delay
and will continue to close to the close limit switch. The operator
will stop if the pressure to close is released before reaching the
close limit.
To prevent possible SEVERE INJURY or DEATH, install reversing
sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used.
Reversing devices are recommended for ALL installations.
CAUTION
CAUTION
A
B
C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE
(Factory Default)
C2 WIRING TYPE WITH MONITORED SAFETY DEVICE
Momentary contact to open and stop with constant
pressure to close.
Open override that reverses when closing by any opening
device.
Wiring for safety device to reverse.
NOTE:
The operator
will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
Momentary contact to open and stop with constant
pressure to close.
Open override that reverses when closing by any opening
device.
Wiring for safety device to reverse.
NOTE:
The operator
will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available.
Remove any monitored safety devices.
Disconnect then reconnect power to the operator.
Press and hold the LEARN and STOP buttons until the LED goes
out (approximately 3 seconds).
Press and hold the LEARN and CLOSE buttons until the LED goes
out (approximately 3 seconds).
NON-MONITORED SAFETY DEVICE
MONITORED SAFETY DEVICE
Sensing
Edge
Photo Eye
014A1030
014A1030
Logic Board
Logic Board
Electrical Box
Electrical Box
D14
LED
LEARN
1
2
3
4
5
6
7
STOP
CLOSE
OPEN
D14
LED
LEARN
1
2
3
4
5
6
7
STOP
CLOSE
OPEN
RESET TO C2 WIRING TYPE
(Factory Default)
TO PROGRAM
2
BASIC PROGRAMMING
INTRODUCTION