USER INTERFACE The PPWR user interface consists of a 22 character by 5 line LCD display, 3 "soft keys", Down/Up arrows and a numeric keypad. Scroll Indicator If more than 3 options exist, a scroll indicator appears on the left margin of lines 2, 3, and 4. The scroll indicator shows the relative position within the list. Antenna Connection For the direct antenna or the antenna extension kit. Line 1: Menu and function mode. Lines 2, 3, and 4: Menu selections and data. Line 5: Soft key function modes. Backup memory module indicator (LiftMaster® logo screen only) Menu/Data selection shown in inverse font. LCD Screen System programming and status display. "SOFT" Keys Soft key functions are defined by the label on line 5 of the display. The functions change according to the menu selection. Down/Up Keys For navigation in the menus. Numeric Keypad Numeric data is entered through the numeric keypad. PROGRAMMING COMMANDS The table below describes the commands used to program the receiver. Insert wiring MAIN MENU COMMAND DESCRIPTION WIEGAND FORMAT 26 BIT (DEFAULT) 30 BIT 31 BIT 34 BIT EVEN 34 BIT ODD 50 BIT 26 Bit Wiegand output code. 30 Bit Wiegand output code. 31 Bit Wiegand output code. 34 Bit EVEN Wiegand output code. 34 Bit ODD Wiegand output code. 50 Bit Wiegand output code. BUTTON FILTER BUTTON 1 IS ON BUTTON 2 IS ON BUTTON 3 IS ON Used when multiple receivers are within range of each other. MODE SELECT PASS THRU (DEFAULT) ADVANCED Passes all received remote control signals to the access system host controller. Receiver only passes signals from a remote control with a previously programmed facility code. All other signals are blocked. SECURITY TABLE If advanced mode is turned off this option is disabled and will appear as NOT AVAILABLE FOR PASS THRU MODE PROGRAM LIST CHANGE FC OUT DELETE SETTINGS PIN DEALER INFO FIRMWARE VERSION BEEP MEMORY DUPLICATE MEMORY RESTORE MEMORY CONTRAST LANGUAGE FACTORY DEFAULT Learn a facility code from any remote control in a batch that the PPWR will respond to. Also used to resolve any conflicts in code translation. Displays a list of all programmed facility codes showing facility code conflicts and facility code changes. Options to delete or resolve facility code conflicts. Change the 6-digit PIN number for the receiver. Display and edit the dealer 10-digit phone number. Displays the current firmware version. Turn the audible feedback on or off. Creates a memory backup. A memory module must be installed. Restores a memory backup from a memory module. An indicator appears on the LiftMaster® logo screen if a backup memory module is installed. NOTE: Content of memory module will over-write any information already stored in the receiver memory. Press Down or Up arrows to adjust LCD contrast. Sets language: English (Default), Spanish, and French. Reset receiver settings to factory default. 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

2
Antenna Connection
For the direct antenna or the
antenna extension kit.
“SOFT” Keys
Soft key functions are defined by
the label on line 5 of the display.
The functions change according
to the menu selection.
LCD Screen
System programming and status
display.
Down/Up Keys
For navigation in the menus.
Numeric Keypad
Numeric data is entered
through the numeric keypad.
Insert wiring
USER INTERFACE
The PPWR user interface consists of a 22 character by 5 line LCD display, 3 “soft keys”, Down/Up arrows and a numeric keypad.
Line 1:
Menu and function mode.
Lines 2, 3, and 4:
Menu selections and data.
Line 5:
Soft key function modes.
Scroll Indicator
If more than 3 options exist, a scroll indicator appears on the
left margin of lines 2, 3, and 4. The scroll indicator shows the
relative position within the list.
Menu/Data selection shown
in inverse font.
Backup memory module indicator
(LiftMaster
®
logo screen only)
MAIN MENU
COMMAND
DESCRIPTION
WIEGAND FORMAT
26 BIT (DEFAULT)
26 Bit Wiegand output code.
30 BIT
30 Bit Wiegand output code.
31 BIT
31 Bit Wiegand output code.
34 BIT EVEN
34 Bit EVEN Wiegand output code.
34 BIT ODD
34 Bit ODD Wiegand output code.
50 BIT
50 Bit Wiegand output code.
BUTTON FILTER
BUTTON 1 IS ON
Used when multiple receivers are within range of each other.
BUTTON 2 IS ON
BUTTON 3 IS ON
MODE SELECT
PASS THRU (DEFAULT)
Passes all received remote control signals to the access system host controller.
ADVANCED
Receiver only passes signals from a remote control with a previously programmed facility
code. All other signals are blocked.
SECURITY TABLE
If advanced mode is
turned off this option is
disabled and will appear
as NOT AVAILABLE FOR
PASS THRU MODE
PROGRAM
Learn a facility code from any remote control in a batch that the PPWR will respond to.
Also used to resolve any conflicts in code translation.
LIST
CHANGE FC OUT
Displays a list of all programmed facility codes showing facility code conflicts and facility
code changes. Options to delete or resolve facility code conflicts.
DELETE
SETTINGS
PIN
Change the 6-digit PIN number for the receiver.
DEALER INFO
Display and edit the dealer 10-digit phone number.
FIRMWARE VERSION
Displays the current firmware version.
BEEP
Turn the audible feedback on or off.
MEMORY
DUPLICATE MEMORY
Creates a memory backup. A memory module must be installed.
RESTORE MEMORY
Restores a memory backup from a memory module. An indicator appears on the
LiftMaster
®
logo screen if a backup memory module is installed.
NOTE:
Content of memory module will over-write any information already stored in the
receiver memory.
CONTRAST
Press Down or Up arrows to adjust LCD contrast.
LANGUAGE
Sets language: English (Default), Spanish, and French.
FACTORY DEFAULT
Reset receiver settings to factory default.
PROGRAMMING COMMANDS
The table below describes the commands used to program the receiver.