LiftMaster RSL12UL UL 325-Listed Gate Operators Guide - Page 19

H C T D C U L

Page 19 highlights

MASTERFUL ENGINEERING. MECHANICS - -24VDC Cont inuous -Duty Mo to r --O pe rat or Du t y Rat i n g : H igh- C y cle , H igh-Tem p er a t u r e Continuous Duty --Worm ge ar Red u ct i on : Oil- B a t h G e a r bo x with 28:1 Gear Reducer POWER --120/230V S ingle- Pha s e --Ac ce ssor y Power: 24V DC 500mA Output HCTDCUL SPECIALTY OVERHEAD OPERATOR COMMERCIAL-GRADE DESIGN --Chassis: Cons t r uc t e d w ith 1/ 4 in. G o ld Zinc-Plated Steel for Rust Prevention --Trolle y Assem b ly: H e a v y - Duty 12- G a uge Steel Track with 6 UHMW Rollers - -U L ® U s a g e C l a s s i f i c a t i o n : I I , I I I a n d I V --Weight s: --Po werhead = 86 lbs . --HCT08-8 ft . Rail = 93 lbs . --HCT10- 1 0 ft . Rail = 111 lbs . --HCT12- 1 2 ft . Rail = 129 lbs . TEMPERATURE SPECIFICATIONS -4°F (-20°C) to 140°F (60°C) BATTERY BACKUP OPERATION Battery Cycles Standby Time (2) 7Ah 112 24 Days RAILS HCT08: 121.5" HCT10: 145.5" HCT12: 169.5" CAPACITIES Rated for Overhead Doors or Gates with up to 12 ft. Rail or Weighing up to 700 lbs. 700 Ibs. 600 GATE TRAVEL SPEED BI-PART DELAY OFF (DEFAULT) = 8 IN./SEC. OPEN SPEED* 400 200 0 12 ft. BI-PART DELAY ON (FAST) = 11 IN./SEC. OPEN SPEED* *Select gate travel speed using the BI-PART DELAY switch and enable a high-speed open option to help flow in high-traffic areas (open speed only). STANDARD FEATURES. PRE-MOTION WARNING ALARM --Acti v a tes O n-Boar d A lar m 3 S e c o nds Prior to Gate Motion EXTERNAL ALARM RESET BUTTON --I nsta ntly Resets t he Built -In S a f e ty Alarm Siren MAXIMUM-RUN TIMER --Pro te cts Agains t Dama ge t o t he G a te a nd Operator by Limiting the Unit's Run Time to 120 Seconds DYNAMIC BRAKING SYSTEM --Adds Su bstan tial Ga t e Po s it io n C o nt r o l at All Points of Travel MONITORED SAFETY INPUTS - -3 M ai n B oar d , 3 E x p an si on B oar d SECURITY+ 2.0® ON-BOARD RADIO RECEIVER - -Tr i -B a n d 31 0 / 3 1 5 / 3 9 0 M H z Fr eq u en cy --U p t o 50 R em ot e C on t r ol s ( U n l i m i t ed with 811LM/813LM) LED DIAGNOSTIC DISPLAY - -S i m p l i f i e s I n st al l a t i on an d Tr o u b l e s h o o t i n g PROGRAMMABLE AUXILIARY RELAYS - -Ma k e A d d i n g A d d i t i on al Fea t u r es E asy © 2018 LiftMaster All Rights Reserved 300 Windsor Drive, Oak Brook, IL 60523 LiftMaster.com UL® and the UL logo are trademarks of UL LLC © 2018 All Rights Reserved. LMPAENPGHCTDCU 5/18 S U P P O R T. For Support Tools and Training Videos, Visit L i f t M a s t e r Tr a i n i n g . c o m For More Information on Gate Operators, Visit L i f t M a s t e r. c o m / U L 3 2 5 G a t e s To Find the Right Perimeter Access Solution for You, Visit L i f t M a s t e r. c o m / S o l u t i o n - G e n e r a t o r Sales Support: 800.282.6225 Technical Support Center: 800.528.2806 To Order: 800.323.2276

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

MECHANICS
-
120/230V
Single-Phase
POWER
COMMERCIAL-GRADE DESIGN
-4°F (-20°C) to 140°F (60°C)
TEMPERATURE SPECIFICATIONS
H C T D C U L
SPECIALTY OVERHEAD OPERATOR
MASTERFUL ENGINEERING.
STANDARD FEATURES.
SUPPORT.
For Support Tools and Training Videos, Visit
LiftMasterTraining.com
For More Information on Gate Operators, Visit
LiftMaster.com/UL325Gates
To Find the Right Perimeter Access Solution for
You, Visit
LiftMaster.com/Solution-Generator
Sales Support:
800.282.6225
Technical Support Center:
800.528.2806
To Order:
800.323.2276
PRE-MOTION WARNING ALARM
-Activates On-Board Alarm 3 Seconds
Prior to Gate Motion
EXTERNAL ALARM RESET BUTTON
-Instantly Resets the Built-In Safety
Alarm Siren
MAXIMUM-RUN TIMER
-Protects Against Damage to the Gate and
Operator by Limiting the Unit’s Run Time
to 120 Seconds
DYNAMIC BRAKING SYSTEM
-Adds Substantial Gate Position Control
at All Points of Travel
© 2018 LiftMaster All Rights Reserved
300 Windsor Drive, Oak Brook, IL 60523
LiftMaster.com
UL
®
and the UL logo are trademarks of UL LLC © 2018 All Rights Reserved.
LMPAENPGHCTDCU 5/18
BATTERY BACKUP OPERATION
Battery
Cycles
Standby
Time
(2) 7Ah
112
24 Days
GATE TRAVEL SPEED
BI-PART DELAY OFF (DEFAULT) = 8 IN./SEC.
OPEN SPEED*
BI-PART DELAY ON (FAST) = 11 IN./SEC.
OPEN SPEED*
RAILS
HCT08
: 121.5"
HCT10
: 145.5"
HCT12
: 169.5"
CAPACITIES
Rated for Overhead Doors or
Gates with up to 12 ft. Rail or
Weighing up to 700 lbs.
700 Ibs.
600
400
200
0
12 ft.
-
Chassis
:
Constructed with 1/4 in. Gold
Zinc-Plated Steel for Rust Prevention
-
Trolley Assembly
:
Heavy-Duty 12-Gauge
Steel Track with 6 UHMW Rollers
-
UL
®
Usage Classification
: II, III and IV
-
Weights
:
-Powerhead = 86 lbs.
-HCT08—8 ft. Rail = 93 lbs.
-HCT10—10 ft. Rail = 111 lbs.
-HCT12—12 ft. Rail = 129 lbs.
-
24VDC
Continuous-Duty Motor
-
Operator Duty Rating
: High-Cycle, High-Temperature
Continuous Duty
-
Wormgear Reduction
: Oil-Bath Gearbox
with 28:1 Gear Reducer
-
Accessory Power
: 24VDC 500mA Output
MONITORED SAFETY INPUTS
-3 Main Board, 3 Expansion Board
SECURITY+ 2.0
®
ON-BOARD
RADIO RECEIVER
-Tri-Band 310/315/390 MHz Frequency
-Up to 50 Remote Controls (Unlimited
with 811LM/813LM)
LED DIAGNOSTIC DISPLAY
-Simplifies Installation and
Troubleshooting
PROGRAMMABLE AUXILIARY RELAYS
-Make Adding Additional Features Easy
*Select gate travel speed using the BI-PART DELAY
switch and enable a high-speed open option to
help flow in high-traffic areas (open speed only).