LiftMaster RSL12VDC RSL12VDC Installation Manual - Page 32
Troubleshooting Chart, Symptom, Possible Causes, Solutions - error codes
View all LiftMaster RSL12VDC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
TROUBLESHOOTING TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a) No power to control board a) Check AC and battery power run and error code b) Open fuse b) Check fuses display not on. c) If on battery power only, low or dead batteries c) Charge batteries by AC or solar power or replace batteries d) Defective control board d) Replace defective control board Control board powers up, but motor does not run. a) Reset switch is stuck b) Stop button active or jumper not in place for stop circuit c) If on battery power only, low or dead batteries a) Check reset switch b) Check Stop button is not "stuck on", or verify that the stop button is a normally closed circuit, or put a jumper on the stop circuit. c) Charges batteries by AC or solar power or replace batteries d) Open or Close input active d) Check all Open and Close inputs for a "stuck on" input e) Entrapment Protection Device active e) Check all Entrapment Protection Device inputs for a "stuck on" sensor f) Vehicle loop detector or probe active f) Check all vehicle detector inputs for a "stuck on" detector g) Defective control board g) Replace defective control board Gate moves, but a) Gate does not move to a limit position cannot set correct b) Gate is too difficult to move limits. a) Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b) Gate must move easily and freely through its entire range, limit to limit. Repair gate as needed. Gate does not fully open or fully close when setting limits. a) Gate does not move to a limit position b) Gate is too difficult to move a) Use manual disconnect, manually move gate, and ensure gate moves easily limit to limit. Repair gate as needed. b) Gate must move easily and freely through its entire range, limit to limit. Repair gate as needed. Operator does not respond to a wired control/command (example: Open, Close, SBC, etc.) a) Check Open and Close command input LEDs a) Check all Open and Close inputs for a "stuck on" input b) Stop button is active b) Check Stop button is not "stuck on" c) Reset button is stuck c) Check Reset button d) If on battery power only, low or dead batteries d) Charges batteries by AC or solar power or replace batteries e) Entrapment Protection Device active e) Check all Entrapment Protection Device inputs for a "stuck on" sensor f) Vehicle loop detector or vehicle probe active f) Check all vehicle detector inputs for a "stuck on" detector Operator does not respond to a wireless control or transmitter a) Check XMITTER LED when wireless control is active b) Stop button is active c) Reset button is stuck a) Activate wireless control and check XMITTER LED is on. Re-learn wireless control/transmitter to control board. Replace wireless control as needed. b) Check Stop button is not "stuck on" c) Check Reset button d) Poor radio reception d) Check if similar wired control operates correctly. Check if wireless controls works properly when within a few feet of operator. Check operator's antenna and antenna wire. Check other wireless controls or devices. Gate stops during a) Control (Open, Close) becoming active travel and reverses b) Vehicle loop detector active immediately. c) Low battery voltage a) Check all Open and Close inputs for an active input b) Check all vehicle detector inputs for an active detector c) Battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries Gate opens, but will not close with transmitter or Timer-to-Close. Gate closes, but will not open. a) Open control active b) Vehicle loop detector active c) Loss of AC power with AC FAIL set to OPEN d) Low battery with LOW BATT set to OPEN e Fire Dept input active f) Timer-to-Close not set g) Close Entrapment Protection Device active a) Vehicle loop detector active b) Low battery with LOW BATT option set to CLOSE a) Check all Open inputs for an active input b) Check all vehicle detector inputs for an active detector c) Check AC power and AC Fail option setting d) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries. e) Check Fire Dept input f) Check Timer-to-Close (TTC) setting g) Check all Entrapment Protection Device inputs for an active sensor a) Check all vehicle detector inputs for an active detector b) Check if AC power is available. If no AC power, then running on batteries and battery voltage must be 11.5 Vdc or higher. Charge batteries by AC or solar power or replace batteries. 31