STEP 1 Install the concrete pad and operator Check the national and local building codes before installation. DO NOT run the operator until instructed. 1 Refer to the illustration to determine the location for 2 the concrete pad, conduit, and operator. TOP VIEW OF OPERATOR AND GATE There should only be a maximum of 4" (10.2 cm) from the center of the hinge to the edge of the post or column. If the distance is greater than 4" (10.2 cm) entrapment protection for this area is required. Center of gate hinge 6" Above Ground Below the frost line. (Gate Open 90°) 26-1/2" from the center of the gate hinge to the center of output shaft (conduit location) 26-1/2" 9" 28" Output shaft 9" from the edge of the open gate to the center of the output shaft Install the electrical conduit. Pour a concrete pad (reinforced concrete is recommended). The concrete pad should be 6 inches above the ground and deeper than the frost line. Ensure the pad is tall enough to avoid possible flooding. 3 24" 4 Concrete Anchors 1/2" x 3 1/2" Secure the operator to the concrete pad with appropriate fasteners.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Check the national and local building codes before installation. DO NOT run the operator until instructed.
Install the concrete pad and operator
STEP 1
1
2
3
Install the electrical conduit. Pour a concrete pad
(reinforced concrete is recommended). The concrete pad
should be 6 inches above the ground and deeper than
the frost line. Ensure the pad is tall enough to avoid
possible flooding.
Secure the operator to the concrete pad with appropriate
fasteners.
Refer to the illustration to determine the location for
the concrete pad, conduit, and operator.
4 Concrete
Anchors
1/2" x 3 1/2"
Below the
frost line.
6" Above Ground
TOP VIEW OF OPERATOR AND GATE
26-1/2" from the
center of the gate
hinge to the center of
output shaft
There should only be a maximum of 4"
(10.2 cm) from the center of the hinge
to the edge of the post or column. If the
distance is greater than 4" (10.2 cm)
entrapment protection for this area is
required.
9" from the edge of the
open gate to the center
of the output shaft
(conduit location)
Output shaft
Center of gate hinge
(Gate Open 90
°
)
24"
28"
9"
26-1/2"