LiftMaster SRDRKP LiftMaster Smart Reader Installation Guide - English French - Page 1

LiftMaster SRDRKP Manual

Page 1 highlights

SMART READER INSTALLATION GUIDE Included Parts: • Reader, Backplate, Wall Plate • #6 Machine Screws - QTY 2 • #6 Self Tapping Screws - QTY 2 • #4-40 Phillips Screw • #4-40 Pin-in-Torx Screw Tools Needed (Not Supplies): • Phillips Screwdriver • 1" (25 mm), 1/8" Drill bits • T8 Security Torx Bit (optional for increased tamper detection) • #6-32 Tap if required Wiring Connections Red Power In Black Ground Shield Shield Ground Green Wiegand Data 0 RS485A(+) White Wiegand Data 1 RS485A(-) Yellow* Beeper Control Brown* Tamper Out Blue* Green LED Control Orange* Red LED Control *These wires are only used in Wiegand mode. **All wiring methods used shall be in accordance with the Nat•ional Electrical Code, ANSI/NFPA 70. Readers must be powered by a compatible UL Listed, power limited, access control panel rated 5-16 VDC. A. Install the Metal Wall Plate to the Wall/Single Gang box. • Use the provided #6 screws. B. Wire the Cable to the Control Panel. C. Attach the Reader to the Wall Plate and Install the Reader Screw. • Follow steps 1 through 3 below to ensure proper alignment. Install either the #4-40 screw or Pin-in-Torx screw at the bottom. RF TECHNOLOGIES 125 kHz, 13.56 MHz & BLE Mobile CURRENT VOLTAGE TEMPERATURE CABLE LENGTH Single Gang Keypad Model Model SRDRST SRDRKP 120 mA average, 170 mA peak 145 mA average, 195 mA peak 5-16 VDC (NEVER APPLY MORE THAN 16V) UL™ tested -35° to 66°C and EN -40° to 70°C and 95% humidity (UL™ tested -31˚F to 150˚F and EN -40˚ to 158˚F and 95% humidity) Communication Lines Wiegand: 200 feet - 22 AW G 300 feet - 20 AWG 500 feet -18 AWG OSDP @ 12 VDC and 25˚C (77˚F) = 1000 feet - 22 AWG Twisted Pair NOTE: Do NOT use the Power Supply provided with the CAPXLV or CAPXM to directly power up this reader. It is 24V and will cause damage to the reader. NOTE: LED Control not available when connected to a CAPXS. WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. 1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

1
SMART READER
INSTALLATION GUIDE
Included Parts:
• Reader, Backplate, Wall Plate
#6 Machine Screws – QTY 2
#6 Self Tapping Screws – QTY 2
• #4-40 Phillips Screw
• #4-40 Pin-in-Torx Screw
Wiring Connections
Red
Power In
Black
Ground
Shield
Shield Ground
Green
Wiegand Data 0
RS485A(+)
White
Wiegand Data 1
RS485A(–)
Yellow*
Beeper Control
Brown*
Tamper Out
Blue*
Green LED Control
Orange
*
Red LED Control
Single Gang
Keypad
RF TECHNOLOGIES
Model
Model
125 kHz, 13.56 MHz & BLE Mobile
SRDRST
SRDRKP
CURRENT
120 mA average, 170 mA peak
145 mA average, 195 mA peak
VOLTAGE
5-16 VDC (NEVER APPLY MORE THAN 16V)
TEMPERATURE
UL™ tested –35° to 66°C and EN –40° to 70°C and 95% humidity
(UL™ tested -31˚F to 150˚F and EN -40˚ to 158˚F and 95% humidity)
CABLE LENGTH
Communication Lines
Wiegand:
200 feet - 22 AW G
300 feet - 20 AWG
500 feet -18 AWG
OSDP @ 12 VDC and 25˚C (77˚F)
= 1000 feet - 22 AWG Twisted Pair
NOTE:
Do NOT use the Power Supply provided with the CAPXLV or CAPXM to directly power up this reader. It is 24V and will cause damage to the reader.
NOTE:
LED Control not available when connected to a CAPXS.
Tools Needed (Not Supplies):
• Phillips Screwdriver
1” (25 mm), 1/8” Drill bits
T8 Security Torx Bit (optional for increased tamper detection)
• #6-32 Tap if required
*These wires are only used in Wiegand mode.
**All wiring methods used shall be in accordance
with the National Electrical Code, ANSI/NFPA 70.
Readers must be powered by a compatible UL
Listed, power limited, access control panel rated
5–16 VDC.
A.
Install the Metal Wall Plate to the Wall/Single Gang box.
• Use the provided #6 screws.
B.
Wire the Cable to the Control Panel.
C.
Attach the Reader to the Wall Plate and Install the Reader Screw.
Follow steps 1 through 3 below to ensure proper alignment. Install either the #4-40
screw or Pin-in-Torx screw at the bottom.
WARNING:
This product can expose you to chemicals including lead, which are known
to the State of California to cause cancer or birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.