Linksys SPA921 Cisco SPA9000 Voice System Administration Guide - Page 255
SIP Proxy-Require, SIP Remote-Party-ID
UPC - 745883570799
View all Linksys SPA921 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 255 highlights
SPA9000 Field Reference Voice tab B Auth Resync-Reboot SIP Proxy-Require SIP Remote-Party-ID SIP GUID If this feature is enabled, the SPA9000 authenticates the sender when it receives the NOTIFY resync reboot (RFC 2617) message. To use this feature, select yes. Otherwise, select no. Default: yes The SIP proxy can support a specific extension or behavior when it detects this header from the user agent. If this field is configured and the proxy does not support it, it responds with the message, unsupported. Enter the appropriate header in the field provided. Default: blank To use the Remote-Party-ID header instead of the From header, select yes. Otherwise, select no. Default: yes The Global Unique ID is generated for each line for each device. When it is enabled, the SPA9000 adds a GUID header in the SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. Default: no SPA9000 Voice System Administration Guide 253