Segment 2: On=0.38s, Off=0s, with Frequency 2
UPC - 745883570836
View all Linksys SPA922 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Creating Provisioning Scripts Data Types 2 Example 2-Stutter tone: 350@-19,440@-19;2(.1/.1/1+2);10(*/0/1+2) Number of Frequencies = 2 Frequency 1 = 350 Hz at -19 dBm Frequency 2 = 440 Hz at -19 dBm Number of Cadence Sections = 2 Cadence Section 1: Section Length = 2s Number of Segments = 1 Segment 1: On=0.1s, Off=0.1s with Frequencies 1 and 2 Cadence Section 2: Section Length = 10s Number of Segments = 1 Segment 1: On=forever, with Frequencies 1 and 2 Total Tone Length = 12s Example 3-SIT tone: 985@-16,1428@-16,1777@-16;20(.380/0/1,.380/0/2,.380/0/ 3,0/4/0) Number of Frequencies = 3 Frequency 1 = 985 Hz at -16 dBm Frequency 2 = 1428 Hz at -16 dBm Frequency 3 = 1777 Hz at -16 dBm Number of Cadence Sections = 1 Cadence Section 1: Section Length = 20s Number of Segments = 4 Segment 1: On=0.38s, Off=0s, with Frequency 1 Segment 2: On=0.38s, Off=0s, with Frequency 2 Segment 3: On=0.38s, Off=0s, with Frequency 3 Segment 4: On=0s, Off=4s, with no frequency components Total Tone Length = 20s Cisco Small Business IP Telephony Devices Provisioning Guide 61