Linksys SPA942 Cisco Small Business Pro SPA and Wireless IP Phone Administrati - Page 40
Configuring Speed Dial, Red Fast Blink: Ringing - problems
UPC - 745883569113
View all Linksys SPA942 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
3 Configuring Lines and Extensions Configuring Lines c. Enter the following string in the Extended Function field: fnc=blf+cp;sub=Stephanie@$PROXY;ext=300@$PROXY Using the following syntax: fnc=type;sub=stationname@$PROXY;ext=extension#@$PROXY where: - fnc: function - blf: busy lamp field - cp: call pickup - sub: station name - ext: extension STEP 6 Click Submit All Changes. After the phone reboots, the SPA962 (in this example) should show the following color LEDs for the monitored lines: • Green: Available • Red: Busy • Red Fast Blink: Ringing If the phone LEDs display orange or slow blinking orange, there is a problem: Orange denotes that the phone failed to subscribe (received 4xx response) and slow blinking orange denotes an undefined problem (there may be no response to subscribe, or BLF). In this example, after this configuration, Bob will be able to monitor Stephanie's line. He can press line button 4 to pick up a call ringing at Stephanie's line. Configuring Speed Dial In this example, the assistant Bob (extension 200) has another idle line (line 5) on his SPA962. He would like to be able to speed dial his supervisor Mark (extension 400) from that line. To configure this feature for Bob's SPA962: STEP 1 Log in to the web administration interface. STEP 2 Click Admin Login. 38 Cisco SPA and Wireless IP Phone Administration Guide