Lowrance Fuel Data Manager Installation Guide - Page 1

Lowrance Fuel Data Manager Manual

Page 1 highlights

Fuel Data Manager Installation Guide *988-10925-001* What's in the box Fuel Data Manager NMEA 2000 T-Joiner Tools required Drill with 22 mm (7/8") drill bit Other parts required Zip ties for securing Fuel Data Manager Overview The Fuel Data Manager accumulates fuel used data from fuel flow messages it receives from up to three NMEA 2000 compatible engines, enabling the displaying of Fuel Range on Navico display units. ! You should read all of the installation instructions before proceeding. Decide where to install all components before drilling any holes in your vessel. A 46 cm (18") B A Fuel Data Manager B NMEA 2000 connector Plan the installation Example of installation Install the Fuel Data Manager Connect the Fuel Data Manager to the network Dimensions To install the Fuel Data Manager, route the sensor's cable connec- tor to the NMEA 2000 T-Joiner on the network backbone where A you intend to attach it and plug it in. A B 17.1 mm (0.67") 9.6 mm (0.38") C 86.5 mm (3.4") D B A Fuel Data Manager B NMEA 2000 CAN bus backbone (NMEA 2000, IEC61162-1/2) A Fuel Data Manager B NMEA 2000 drop cable C NMEA 2000 CAN bus backbone D 12 V DC Power supply. Connect via a switch and 5 amp fuse 20 mm (0.8") 11.5 mm (0.45") Specifications Can accumulate fuel used data from fuel flow messages it receives from up to three NMEA 2000 compatible engines. Fuel used data includes: Fuel Range, Fuel Used, Trip Fuel Used and Seasonal Fuel Used. PGNs transmitted 59392 - ISO Acknowledgment 60928 - ISO Address Claim 126996 - Product Information

  • 1

*988-10925-001*
What’s in the box
Fuel Data Manager
Installation Guide
Tools required
Overview
Plan the installation
Example of installation
Install the Fuel Data Manager
To install the Fuel Data Manager, route the sensor’s cable connec-
tor to the NMEA 2000
T-Joiner on the network backbone where
you intend to attach it and plug it in.
Drill with 22 mm (7/8”) drill bit
Zip ties for securing Fuel Data
Manager
The Fuel Data Manager accumulates fuel used data from fuel flow
messages it receives from up to three NMEA 2000 compatible
engines, enabling the displaying of Fuel Range on Navico display
units.
!
You should read all of the installation instructions
before proceeding. Decide where to install all components
before drilling any holes in your vessel.
Other parts required
Fuel Data Manager
NMEA 2000
T-Joiner
A
Fuel Data Manager
B
NMEA 2000 connector
A
Fuel Data Manager
B
NMEA 2000 CAN bus backbone (NMEA 2000, IEC61162-1/2)
A
B
46 cm
(18”)
Dimensions
Connect the Fuel Data Manager to the network
A
B
A
Fuel Data Manager
B
NMEA 2000 drop cable
C
NMEA 2000 CAN bus backbone
D 12 V DC Power supply.
Connect via a switch and 5 amp fuse
Specifications
Can accumulate fuel used data from fuel flow messages it
receives from up to three NMEA 2000 compatible engines.
Fuel used data includes: Fuel Range, Fuel Used, Trip Fuel
Used and Seasonal Fuel Used.
PGNs transmitted
59392 – ISO Acknowledgment
60928 – ISO Address Claim
126996 – Product Information
A
B
C
D
86.5 mm
(3.4”)
17.1 mm (0.67”)
9.6 mm (0.38”)
20 mm (0.8”)
11.5 mm (0.45”)