Lowrance HDS-9 Carbon - No Transducer Installation Manual EN - Page 55
Fuel Level, Set to full, Calibrate, actual amount used, Fuel K-Value, Device list
View all Lowrance HDS-9 Carbon - No Transducer manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
1. Start with a full tank and run the engine as it would normally be operated. 2. After at least several liters (a few gallons) have been used, the tank should be fully refilled, and the Set to full option selected. 3. Select the Calibrate option. 4. Set the actual amount used based on amount of fuel added to the tank. 5. Select OK to save settings. The Fuel K-Value should now show a new value. Ú Note: To calibrate multiple engines repeat the steps above, one engine at a time. Alternatively, run all engines simultaneously, and divide the Actual amount used by the number of engines. This assumes reasonably even fuel consumption on all engines. Ú Note: The Calibrate option is only available when Set to full is selected, and a Fuel Flow is connected and set up as a source. Ú Note: A maximum of 8 engines is supported using Fuel Flow sensors. Fuel Level With the use of a Navico Fluid Level device connected to a suitable tank level sensor, it is possible to measure the amount of fuel remaining in any equipped tank. The number of tanks must be set in Vessel Setup dialog, initiated from the Fuel setting options page, to allow discrete tank assignment of the Fluid Level devices. Select Device list on the Network page, and view the Device Configuration dialog for each sensor, and set the Tank location, Fluid type, and Tank size. Software Setup | HDS Carbon Installation Manual 55