Mackie SWA1801z Owner's Manual - Page 4

Rear Panel Description - subwoofer system

Page 4 highlights

REAR PANEL DESCRIPTION POWER Switch Use this switch to turn the SWA1801z on and off. Make sure the signal source's level control is turned down before you turn it on. AC Receptacle This is where you connect the AC linecord to provide AC power to the SWA1801z's built-in power amplifiers. Plug the linecord into an AC socket properly configured for your particular model. LIMIT Indicator The SWA1801z has a built-in limiter that prevents the amplifier outputs from overdriving the transducers. The LIMIT indicator lights when the limiter is activated. It's okay for the LIMIT indicator to blink occasionally, but if it blinks frequently or lights continuously, turn down the level control until the LIMIT indicator only blinks occasionally. POWER Indicator When the POWER switch is turned on and the linecord is connected to an active AC power supply, this indicator lights green to let you know that you're ready to rock and roll. The cool blue LED on the front of the cabinet works in the same way. FULL RANGE INPUT These are female XLR-type connectors that accept a balanced line-level signal from a mixing console or other signal source. THRU (FULL RANGE OUTPUT) These are male XLR-type connectors that produce exactly the same signal that is connected to the FULL RANGE INPUT jack. Use it to daisychain several SWA1801z's together off the same signal source. SIGNAL Present Indicator This LED illuminates whenever there is a signal present at the FULL RANGE INPUT connector on the rear panel. THERMAL Indicator The SWA1801z has a thermal protection circuit that monitors the internal temperature of the amplifiers and heatsink. If the internal temperature should exceed a safe operating level, this indicator lights and the signal is muted to allow the amplifier to cool. When the temperature cools to a safe level once again, the thermal protection circuit deactivates and normal operation resumes. Note: Activation of the thermal protection circuit is an indication that you should take steps to avoid continued thermal problems. See "Thermal Considerations" on page 7. HIGH PASS (MID/HIGH FREQ) OUTPUT These are male XLR-type connectors that produce the frequencies above 120Hz. Connect these to a pair of full-range active speakers or to an amplifer/passive speaker combination. The SWA1801z reproduces the frequencies below 120Hz. SUBWOOFER LEVEL Control This adjusts the subwoofer level. The center detent position provides 15 dB of headroom with a nominal +4 dBu input signal. Use this as a starting point for setting the balance between the subwoofer and the main speakers. PHASE This switch reverses the polarity of the subwoofer output. Depending on the placement of the SWA1801z subwoofer relative to the full-range speakers, you may get a better low-frequency response in the room if you reverse the polarity of the subwoofer's signal. Experiment with this switch to determine which position sounds best. 4 POWER ON SWA1801z ACTIVE SUBWOOFER 60Hz-115V-AC FUSE AC125V-T8AL DESIGNED BY MACKOIDS IN WOODINVILLE, WA, USA ©2005 LOUD TECHNOLOGIES INC. "MACKIE" AND THE "RUNNING MAN" FIGURE ARE REGISTERED TRADEMARKS OF LOUD TECHNOLOGIES INC.: • PATENT PENDING CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: THIS SURFACE MAY REACH HIGH TEMPERATURE DURING STANDARD USE. TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS. OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION. TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED COMPONENT. NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR REPLACE WITH THE SAME TYPE FUSE AND RATING. DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE REMPLACER LE FUSIBLE SERIAL NUMBER MANUFACTURING DATE LIMIT SIGNAL THERMAL POWER PARALLEL THRU FULL RANGE (FULL RANGE OUTPUT) INPUT SUBWOOFER CONTROL NORMAL (+4dBu ) L OO +15 SUBWOOFER IN LEVEL REV 180 PHASE R NORMAL HIGH PASS (MID/HIGH FREQ) OUTPUT 120Hz L OUT R

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

4
REAR PANEL DESCRIPTION
POWER Switch
Use this switch to turn the SWA1801z on and
off. Make sure the signal source’s level control is
turned down before you turn it on.
AC Receptacle
This is where you connect the AC linecord
to
provide AC power to the SWA1801z’s built-in pow-
er amplifiers. Plug the linecord into an AC socket
properly configured for your particular model.
LIMIT Indicator
The SWA1801z has a built-in limiter that pre-
vents the amplifier outputs from overdriving the
transducers. The
LIMIT
indicator lights when the
limiter is activated. It’s okay for the
LIMIT
indica-
tor to blink occasionally, but if it blinks frequently
or lights continuously, turn down the level control
until the
LIMIT
indicator only blinks occasionally.
SIGNAL Present Indicator
This LED illuminates whenever there is a
signal present at the
FULL RANGE INPUT
con-
nector on the rear panel.
THERMAL Indicator
The SWA1801z has a thermal protection
circuit that monitors the internal temperature
of the amplifiers and heatsink. If the internal
temperature should exceed a safe operating level,
this indicator lights and the signal is muted to al-
low the amplifier to cool. When the temperature
cools to a safe level once again, the thermal pro-
tection circuit deactivates and normal operation
resumes.
Note:
Activation of the thermal protection
cir-
cuit is an indication that you should take steps to
avoid continued thermal problems. See “Thermal
Considerations” on page 7.
POWER Indicator
When the
POWER
switch is turned on and
the linecord is connected to an active AC power
supply, this indicator lights green to let you know
that you’re ready to rock and roll. The cool blue
LED on the front of the cabinet works in the
same way.
FULL RANGE INPUT
These are female XLR-type connectors that
accept a balanced line-level signal from a mixing
console or other signal source.
THRU (FULL RANGE OUTPUT)
These are male XLR-type connectors that pro-
duce exactly the same signal that is connected
to the
FULL RANGE INPUT
jack. Use it to daisy-
chain several SWA1801z's together off the same
signal source.
HIGH PASS (MID/HIGH FREQ) OUTPUT
These are male XLR-type connectors that
produce the frequencies above 120Hz. Connect
these to a pair of full-range active speakers or to
an amplifer/passive speaker combination. The
SWA1801z reproduces the frequencies below
120Hz.
SUBWOOFER LEVEL Control
This adjusts the subwoofer level. The center
detent position provides 15 dB of headroom with
a nominal +4 dBu input signal. Use this as a
starting point for setting the balance between the
subwoofer and the main speakers.
PHASE
This switch reverses the polarity of the sub-
woofer output. Depending on the placement of
the SWA1801z subwoofer relative to the full-range
speakers, you may get a better low-frequency re-
sponse in the room if you reverse the polarity of the
subwoofer’s signal. Experiment with this switch to
determine which position sounds best.
ON
SWA1801z
ACTIVE SUBWOOFER
POWER
60Hz-115V-AC FUSE AC125V-T8AL
WARNING:
THIS SURFACE MAY REACH HIGH TEMPERATURE DURING
STANDARD USE.
TO ENSURE PROPER OPERATION ALLOW A MINIMUM OF 6 INS.
OF CLEARANCE FROM THIS SURFACE AND ADEQUATE VENTILATION.
TO REDUCE
THE RISK OF ELECTRIC SHOCK DO NOT REMOVE THIS PANEL OR ANY ATTACHED
COMPONENT.
NO OPERATOR SERVICEABLE PARTS INSIDE.
REFER SERVICING TO
QUALIFIED PERSONNEL.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
CAUTION
AVIS:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
DESIGNED BY MACKOIDS IN WOODINVILLE, WA, USA
©2005 LOUD TECHNOLOGIES INC.
"MACKIE" AND THE "RUNNING MAN" FIGURE ARE REGISTERED TRADEMARKS OF
LOUD TECHNOLOGIES INC.:
PATENT PENDING
POWER
THERMAL
THRU
(FULL RANGE OUTPUT)
HIGH PASS
(MID/HIGH FREQ)
OUTPUT
SUBWOOFER
CONTROL
FULL RANGE
INPUT
PARALLEL
120Hz
NORMAL
REV 180
PHASE
L
R
L
R
SUBWOOFER
LEVEL
(+4dBu )
NORMAL
+15
O
O
IN
OUT
SIGNAL
LIMIT