Magnavox P-14NPE Portable AC owners manual - Page 11

LED display, Operation Instructions, Self-Evaporation System

Page 11 highlights

Operation LED display - Shows the set temperature in °C or °F and the Auto-timer settings. - While on DRY and FAN modes, it shows the room temperature. - Shows Error codes and protection code: E1-Room temperature sensor error. E2-Evaporator temperature sensor error. E3-Condenser temperature sensor error (on some models). E4-Display panel communication error. E7-Zero-crossing malfunction. P1-Bottom tray is full--Connect the drain hose and drain the collected water away. If this error repeats, call for service. Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service. Operation Instructions COOL operation -Press the "MODE" button until the "COOL" indicator light comes on. -Press the ADJUST buttons "+" or "-" to select your desired room temperature. The temperature can be set within a range of 17°C~30°C/62°F~86°F. -Press the "FAN SPEED" button to choose the fan speed. DRY operation -Press the "MODE" button until the "DRY" indicator light comes on. -Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW speed. -Keep windows and doors closed for the best dehumidifying effect. -Do not put the duct to window. Self-Evaporation System -In cool mode, this unit is made to self-evaporate. This means, if you keep the rubber stoppers closed on the back of the unit, the water will evaporate and you will not have to drain. -In cases of extreme humidity you may have some water accumulation that the unit is unable to evaporate, in this case the unit will beep 8 times, switch to fan mode and read a p1 error on the display (it will stay like this until the unit is drained) if this happens, you should drain the water from the lower drain (located at the bottom of the unit). -The top drain is used only if you choose DRY mode. * Self Evaporation System works in COOL mode only AUTO operation -When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature. -The air conditioner will control room temperature automatically around the temperature point set by you. -Under AUTO mode, you cannot select the fan speed. FAN operation -Press the "MODE" button until the "FAN " indicator light comes on. -Press the "FAN SPEED" button to choose the fan speed. The temperature cannot be adjusted. -Do not put the duct to window. TIMER operation - While the unit is on, press the TIMER button, the TIMER OFF indicator light illuminates. This indicates the AUTO OFF STOP program is initiated. Press the UP or DOWN button to select the desired time. Press the TIMER button again within 5 seconds, the TIMER ON indicator light illuminates. This indicates the AUTO ON START program is initiated. Press the UP or DOWN button to select the desired time. - While the unit is off, press the TIMER button to initiate the AUTO ON START program. Press the TIMER button again within 5 seconds to initiate the AUTO OFF STOP program. -Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start. -The system will automatically revert back to display the previous temperature setting if there is no operation in a 5 seconds period. -Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timer program. -When the malfunction occurs, the Auto Start/Stop timed program will also be cancelled. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

10
Operation
LED display
- Shows the set temperature in °C or °F and the Auto-timer settings.
- While on DRY and FAN modes, it shows the room temperature.
- Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E3-Condenser temperature sensor error (on some models).
E4-Display panel communication error.
E7-Zero-crossing malfunction.
P1-Bottom tray is full--Connect the drain hose and drain the collected
water away. If this error repeats, call for service.
Note: When one of the above malfunctions occurs, turn off the unit,
and check for any obstructions. Restart the unit, if the malfunction is
still present, turn off the unit and unplug the power cord. Contact the
manufacturer or its service agents or a similar qualified person for
service.
Operation Instructions
Self-Evaporation System
COOL operation
-Press the "MODE" button until the "COOL" indicator light comes on.
-Press the ADJUST buttons "+" or "-" to select your desired room temperature. The
temperature can be set within a range of 17°C~30°C/62°F~86°F.
-Press the "FAN SPEED" button to choose the fan speed.
DRY operation
-Press the
"MODE" button until the
"DRY" indicator light comes on.
-In cool mode, this unit is made to self-evaporate. This means, if you keep the rubber
stoppers closed on the back of the unit, the water will evaporate and you will not have
to drain.
-In cases of extreme humidity you may have some water accumulation that the unit is
unable to evaporate, in this case the unit will beep 8 times, switch to fan mode and
-Under this mode, you cannot select a fan speed or adjust the temperature. The fan
motor operates at
LOW speed.
-Keep windows and doors closed for the best dehumidifying effect.
-Do not put the duct to window.
read a p1 error on the display (it will stay like this until the unit is drained) if this
happens, you should drain the water from the lower drain (located at the bottom of
the unit).
-The top drain is used only if you choose DRY mode.
* Self Evaporation System works in COOL mode only
AUTO operation
-When you set the air conditioner in AUTO mode, it will automatically select cooling,
heating(cooling only models without), or fan only operation depending on what
temperature you have selected and the room temperature.
-The air conditioner will control room temperature automatically around the temperature
point set by you.
-Under AUTO mode, you cannot select the fan speed.
FAN operation
-Press the
"MODE" button until the "FAN " indicator
light comes on.
-Press the "FAN SPEED" button to choose the fan speed. The temperature cannot be
adjusted.
-Do not put the duct to window.
TIMER operation
- While the unit is on, press the TIMER button, the TIMER OFF indicator light illuminates.
This indicates the AUTO OFF STOP program is initiated. Press the UP or DOWN button
to select the desired time. Press the TIMER button again within 5 seconds, the TIMER
ON indicator light illuminates. This indicates the AUTO ON START program is initiated.
Press the UP or DOWN button to select the desired time.
- While the unit is off, press the TIMER button to initiate the AUTO ON START program.
Press the TIMER button again within 5 seconds to initiate the AUTO OFF STOP program.
-Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up
to 10 hours, then at 1 hour increments up to 24 hours. The control
will count down the
time remaining until start.
-The system will automatically revert back to display the previous temperature setting if
there is no operation in a 5 seconds period.
-Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop timer program.
-When the malfunction occurs, the Auto Start/Stop timed program will also be cancelled.