G1100(US)_GU1835 2004.2.6 1:04 PM ページ4 Symbols and Meanings In accordance with the European requirements (eec Directives),the specified symbols as shown in the following table are used for the products and this instruction manual. Read the operator's instruction manual. Fire, open light and smoking prohibited. Stay clear of the hot surface. Caution, risk of electric shock. Exhaust gas is poisonous. Do not operate in an unventilated room. Do not connect the generator to the commercial power lines. US GB Stop the engine before refueling. GB GB GB ON (power and Engine) GB IN-position of a bistable push control Engine start (Electric start) GB OFF GB (power and Engine) Protective earth (ground) Engine stop GB GB Alternating current Fuse Diesel fuel GB GB Direct current Engine oil Fast GB GB Plus ; positive polarity GB Add oil Slow GB Minus ; negative polarity Battery charging condition OUT-position of a bistable push control Choke ; cold starting aid Pr Rated power (kW) COP Continuous power COS r Rated power factor fr Rated frequency (Hz) Ur Rated voltage (V) H max Maximum site altitude above sea-level (m) T max Maximum ambient temperature ( ) Ir Rated current (A) m Mass (kg) 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

4
US
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
GB
Symbols and Meanings
In accordance with the European requirements (eec Directives),the specified symbols as shown in the
following table are used for the products and this instruction manual.
Read the operator's instruction manual.
Stay clear of the hot surface.
Exhaust gas is poisonous.
Do not operate in an unventilated room.
Stop the engine before refueling.
Fire, open light and smoking
prohibited.
Caution, risk of electric shock.
Do not connect the generator to
the commercial power lines.
Engine oil
ON
(power and Engine)
Add oil
Battery charging
condition
OFF
(power and Engine)
Alternating current
Direct current
Plus ;
positive polarity
Minus ;
negative polarity
OUT-position of a
bistable push control
IN-position of a
bistable push control
Protective earth
(ground)
Fuse
Choke ;
cold starting aid
Engine start
(Electric start)
Engine stop
Diesel fue
l
Fast
Slow
P
r
Rated power (kW)
COP
Continuous power
COS
r
Rated power factor
f
r
Rated frequency (Hz)
U
r
Rated voltage (V)
I
r
Rated current (A)
H
max
Maximum site altitude
above sea-level (m)
T
max
Maximum ambient
temperature (
)
m
Mass (kg)
G1100(US)_GU1835
2004.2.6
1:04 PM
ページ4