Makita SK106DZ SK106 Instruction Manual - Page 13
Message Codes, Laser, Cause, Correction
View all Makita SK106DZ manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Message Codes Me s s a g e Co d e s Laser ON ON ON OFF OFF Blinks Blinks Blinks every 5 seconds Blinks every 5 seconds Blinks every 5 seconds LED Lights green Blinks green Lights red Lights red 5 seconds then OFF Blinks red Lights red Blinks red Lights red Lights green Blinks green Cause Normal Normal, laser set at reduced brightness Instrument is at low power Battery empty Temperature alert Instrument is out of self-levelling and instrument is at low power Instrument is out of self-levelling Levelling lock is activated and instrument is at low power Normal, levelling lock is activated Levelling lock is activated and laser set at reduced brightness Correction OK - or press ON / Set key for 2 seconds to get strong laser beam Change power supply Change power supply Cool down - or heat up instrument Change power supply Position the instrument almost horizontal Change power supply - - Makita SK106D/SK106GD 13