www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600 This Data Sheet Includes Information On Maytag • Product Model Number (s): • 24" Single Wall Ovens: CWE4800ACB, CWE4800ACE and CWE4200ACB 24" 22" 24" • Dimensions (Actual Size) • Cutout width: 22" Cutout height: 28 11/16" Minimum cabinet width: 24" Minimum cabinet depth: 24" Recommended cutout location from floor : 33 1/4" Distance from face of cabinet to outer edge of open door (Door swing): 21 3/8" Distance from face of cabinet to front of closed door handle: 2 9/16" Overall unit width: 23 7/8" Overall unit height: 29 5/8" Penetration into cabinet: 22 5/8" Oven overlap distances when using cutout dimensions listed above: Top overlap: 13/16" Bottom overlap: 0" Right side overlap: 15/16" Left side overlap: 15/16" • Additional Information • • NOT approved for undercounter installation. • Cutout in cabinet should be level and straight. There are no provisions to level the unit after it is installed. • Construct 5/8" minimum plywood floor flush with bottom of opening. Floor must be level and straight and capable of supporting 140 lbs. • A three-wire, single phase, A.C. 120/208-240 volt, 60Hz cycle electrical system protected by a 30 amp fuse or comparable circuit breaker must be provided . 7/8" O.D. flexible cable 4 feet long is furnished by manufacturer. Mount junction box in area under plywood floor if adequate lower cabinet space is available. Locate 1 1/4" conduit access hole in the back right hand side of the plywood floor. • For European style cabinets (flush front) the required clearance for operation of the oven door is a minimum spacing of 1" between the cutout and the door, hinge or drawer of the cabinet. • CWE4800ACB and CWE4200ACB : Black. • CWE4800ACE : Monochromatic White. See page 2 for additional information Cabinet Opening (not to scale) Provide for 120/208-240 volt electrical connection in this area. 22 5/8" 2 9/16" 28 11/16" 33 1/4" Overall Dimensions (not to scale) 29 5/8" 23 7/8" Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter- mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2002. 214 • NEVER reuse Data Sheets. Data Sheets are subject to change without notice. Dimension Express is a FREE service bureau and is updated daily, it makes far more sense to spend the time necessary to request new Data Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. • Call Dimension Express if you have any questions at (775) 833-3633 • • Always refer to a current Code at a Glance or manufacturer directory • • Data Sheet codes change on the first of odd numbered months at 12:01am • BN356 • A214B276 • • 032603 • 95653 • 76241

  • 1
  • 2

24"
Penetration into cabinet:
Cutout height:
Recommended
cutout location from floor :
Distance from face of cabinet to
front of closed door handle:
Cutout width:
Minimum cabinet width:
Distance from face of cabinet to
outer edge of open door (Door swing):
Minimum cabinet depth:
Overall unit width:
Overall unit height:
22 5/8"
29 5/8"
23 7/8"
2 9/16"
21 3/8"
33 1/4"
28 11/16"
22"
24"
Overall Dimensions
(not to scale)
29 5/8"
23 7/8"
Cabinet Opening
(not to scale)
33 1/4"
28 11/16"
22"
24"
24"
2 9/16"
22 5/8"
Provide for
120/208-240
volt
electrical
connection in this
area.
• NOT approved for undercounter installation.
• Cutout in cabinet should be level and straight. There
are no provisions to level the unit after it is installed.
• Construct 5/8" minimum plywood floor flush with
bottom of opening.
Floor must be level and straight and
capable of supporting 140 lbs.
• A three-wire, single phase, A.C. 120/208-240 volt,
60Hz cycle electrical system protected by a 30 amp
fuse or comparable circuit breaker must be provided .
7/8" O.D. flexible cable 4 feet long is furnished by
manufacturer.
Mount junction box in area under
plywood floor if adequate lower cabinet space is
available.
Locate 1 1/4" conduit access hole in the
back right hand side of the plywood floor.
• For European style cabinets (flush front) the required
clearance for operation of the oven door is a minimum
spacing of 1" between the cutout and the door, hinge or
drawer of the cabinet.
• CWE4800ACB and CWE4200ACB : Black.
• CWE4800ACE : Monochromatic White.
See page 2 for additional information
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Dimensions (Actual Size)
• NEVER reuse Data Sheets.
Data Sheets are subject to change without
• Call Dimension Express if you have any questions at (775) 833-3633 •
notice.
Dimension Express is a FREE service bureau and is updated daily,
• Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data
• Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
24"
Single Wall Ovens:
CWE4800ACB, CWE4800ACE and CWE4200ACB
Product Model Number (s):
Subject to change without notice.
This system is designed to
be updated daily if necessary.
Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets.
Because of the difficulty or impracticability of deter-
mining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright ©
Dimension Express, 2002.
This Data Sheet Includes Information On
Top overlap:
Bottom overlap:
Right side overlap:
Left side overlap:
15/16"
15/16"
0"
13/16"
Oven overlap distances when using
cutout dimensions listed above:
BN356 • A214B276 •
• 032603 • 95653 • 76241
Additional Information
214
Maytag