Maytag MDB4621AWB Dimensions - Page 1
Maytag MDB4621AWB - Full Console Dishwasher Manual
View all Maytag MDB4621AWB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Undercounter Dishwasher PRODUCT MODEL NUMBERS MDB3601BW MDB4621AW MDB4629AW Electrical: 120-volt, 60-Hz, AC-only, 15- or 20-amp. fused electrical supply. Use copper wire only. A time-delay fuse or circuit breaker and separate circuit is recommended. Water: A hot water line with 20 to 120 psi (138 to 862 kPa) water pressure. Water temperature must be 120°F (49°C) at dishwasher. Use 3⁄8" O.D. copper tubing with compression fitting (1⁄2" minimum plastic tubing is optional but not recommended). Use a 90° elbow with 3⁄8" N.P.T. external pipe threads on one end to connect to water inlet valve. Do not solder within 6" (15 cm) from water inlet valve. Drain: Use the new drain hose supplied with your dishwasher. If this is not suitable, use a new drain hose with a maximum length of 12 feet (3.7 m) that meets all current AHAM/IAPMO test standards, is resistant to heat and detergent, and fits the drain connector of the dishwasher. Must have a high drain loop 20" (50.8 cm) above the subfloor or floor. Connect drain hose to waste tee or disposer inlet above drain trap in house plumbing and 20" (50.8 cm) minimum above the floor. An air gap must be used if the drain hose is connected to house plumbing lower than 20" (50.8 cm) above subfloor or floor. Use 1⁄2" minimum I.D. drain line fittings. Corner location: Requires a 2" (5.1 cm) minimum clearance between the side of the dishwasher door and wall or cabinet. A side panel kit is available from your dealer for installing your dishwasher at end of cabinet. Grommet is required for electrical cable or power supply cord hole cut in a metal cabinet. Do not install dishwasher over carpeted floor. PRODUCT DIMENSIONS Side View 24" (61 cm)* 337⁄8" (86 cm) min. * to front of door frame 203⁄4" (52.7 cm) CABINET OPENING DIMENSIONS 24" (61 cm)** * Measured from the lowest point on the underside of countertop. ** Minimum, measured from narrowest point of opening. 6" (15.2 cm) 4" (10.2 cm) 21⁄2" (6.4 cm) 4" (10.2 cm) 10" (25.4 cm) 237⁄8" (60.6 cm) Back View 24" (61 cm) 6" (15.2 cm) 4" (10.2 cm) 21⁄2" (6.4 cm) 34" (86.4 cm) min.* 2" (5.1 cm) 5" (12.7 cm) 5" (12.7 cm) 2" (5.1 cm) Cut openings in shaded area of cabinet walls or floor as specified in chart: OPENING FOR: water line drain line direct wire power supply cord DIAMETER: 1⁄2" (1.3 cm) 11⁄2" (3.8 cm) 3⁄4" (1.9 cm) 11⁄2" (3.8 cm) CUSTOM FRONT PANEL DIMENSIONS (Framed) 7⁄32" (5.6 mm) door panel (side view) 7⁄32" (5.6 mm) These panels fit only models with frames around the door and access panels. door panel (front view) 3⁄8" (9.5 mm) 1821⁄32" 1" (47.4 cm) (25.4 mm) 22 31⁄32" (58.3 cm) NOTE: Access panel is wider than door panel. 235⁄16" (59.2 cm) access panel (front view) All edges routed to 7⁄32" (5.6 mm) thickness. Custom door panel more than 7⁄32" (5.6 mm) thick: Route top and bottom to 7⁄32" (5.6 mm) thickness. Custom access panel more than 7⁄32" (5.6 mm) thick: Route all four sides to 7⁄32" (5.6 mm) thickness. Custom panels less than 7⁄32" (5.6 mm) thick: Install spacers behind panels. Cut door panel to clear access panel when door is in open position Ạ. door closed side view Ạ door pivot door opened access panel top view 7⁄32" (5.6 mm) thick access panel frame 1⁄4" (6.4 mm) min. Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation Ref. 8535436-D-MT our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. 07/06/09