Maytag MED6500M Owners Manual - Page 15

Optional 3-Wire Connection Power Supply Cord, Prepare to connect neutral bond wire

Page 15 highlights

4. Remove center screw Remove center terminal block screw (B). 5. Connect neutral wire Optional 3-Wire Connection (Power Supply Cord Shown) IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. 1. Prepare to connect neutral bond wire and neutral wire Install the correct strain relief for your electrical connection method. Remove center terminal block screw (B). Remove neutral bond wire (E) from green external ground conductor screw (A). 2. Connect neutral bond wire and neutral wire Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw. 6. Connect remaining wires Connect neutral bond wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw. 3. Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Venting Requirements." Place remaining wires under outer terminal block screws. Tighten screws. 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

15
4.
Remove center screw
Remove center terminal block screw (B).
5.
Connect neutral wire
Place hooked end of neutral wire (white or center) (C) of
direct wire cable under center terminal block screw (B).
Squeeze hooked end together. Tighten screw.
6.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Insert tab of
terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw. Now, go to “Venting
Requirements.”
Optional 3-Wire Connection (Power Supply Cord
Shown)
IMPORTANT:
You must verify with a qualified electrician that this
grounding method is acceptable before connecting.
1.
Prepare to connect neutral bond wire and
neutral wire
Install the correct strain relief for your electrical connection
method. Remove center terminal block screw (B). Remove
neutral bond wire (E) from green external ground conductor
screw (A).
2.
Connect neutral bond wire and neutral wire
Connect neutral bond wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Place remaining wires under outer terminal block screws.
Tighten screws.