Maytag MED7230HC Owners Manual 1 - Page 5
Location Requirements - dimensions
View all Maytag MED7230HC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
LOCATION REQUIREMENTS Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. You will need: ■ A location allowing for proper exhaust installation. See "Venting Requirements." ■ A separate 15 or 20 A circuit needed for gas dryers and 30 A circuit needed for electric dryers. ■ If using power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of dryer. See "Electrical Requirements." ■ Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance. ■ Level floor with maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), clothes may not tumble properly and automatic sensor cycles may not operate correctly. ■ For garage installation, place dryer at least 18" (460 mm) above floor. ■ Steam models only: Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use your washer's water supply by purchasing the necessary parts noted in "Parts needed." IMPORTANT: Do not operate, install, or store dryer where it will be exposed to water, weather, or at temperatures below 45°F (7°C). Lower temperatures may cause dryer not to shut off at end of automatic sensor cycles, resulting in longer drying times. NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer. INSTALLATION CLEARANCES For each arrangement, consider allowing more space for ease of installation and servicing, spacing for companion appliances and clearances for walls, doors, and floor moldings. Space must be large enough to allow door to fully open. Add spacing on all sides of dryer to reduce noise transfer. If a closet door or louvered door is installed, top and bottom air openings in door are required. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector. Spacing for recessed area or closet installation The dimensions shown are for the recommended spacing allowed. ■ Additional spacing should be considered for ease of installation and servicing. ■ Additional clearances might be required for wall, door, and floor moldings. ■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilations openings are acceptable. ■ Companion appliance spacing should also be considered. 14" max (356 mm) 18" (460 mm) 3" (76 mm) 48 in.2 (310 cm2) 24 in.2 3" (155 cm2) (76 mm) 6"/0"* (152 mm/0 mm) 1" (25 mm) 1"/0"* (25 mm/0 mm) *Recommended/Minimum spacing Mobile home - Additional installation requirements: This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile home construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH. Mobile home installations require: All dryers: ■ Metal exhaust system hardware, available for purchase from your dealer. For further information, see "Assistance or Service" section in your "Quick Reference Guide." ■ Special provisions must be made in mobile homes to introduce outside air into dryer. Openings (such as a nearby window) should be at least twice as large as dryer exhaust opening. For gas dryers mobile home installations: ■ Mobile Home Installation Hold-down Kit is available to order. For further information, see "Assistance or Service" section in your "Quick Reference Guide." 5