Maytag MEDP575GW Installation Instructions - Page 9
Direct Wire Connection
View all Maytag MEDP575GW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
1. Remove center screw B Direct Wire Connection Direct wire strain relief 1. Attach direct wire strain relief A Remove center terminal block screw (B). 2. Connect neutral wire B C Connect neutral wire (white or center) (C) of power supply cord to center terminal block screw (B). Tighten screw. 3. Connect remaining wires B C Unscrew the removable conduit connector (A) and any screws from a 3/4" (19 mm) UL listed strain relief (UL marking on strain relief). Put the threaded section of the strain relief (C) through the hole below the terminal block opening (B). Reaching inside the terminal block opening, screw the removable conduit connector (A) onto the strain relief threads. 2. Attach direct wire cable to strain relief Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. Put direct wire cable through the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Tighten strain relief screw against the direct wire cable. If your wiring looks like this: 4-wire direct connection: Go to 4-Wire Direct Connection on page 10. 3-wire direct connection: Go to 3-Wire Direct Connection on page 10. 9