Maytag MEW5530DDS Installation Instructions - Page 4
Electrical Requirements - parts
UPC - 883049141411
View all Maytag MEW5530DDS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Cabinet Dimensions - Double Oven Double Oven Installed in Cabinet A B F D E C 27" (68.6 cm) models A. 27" (68.6 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door C. 4" to 12" (10.2 to 30.5 cm) bottom of cutout to floor D. 25¹⁄₂" (64.8 cm) cutout width E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door F. 50.0" (127.0 cm) min. cutout height 30" (76.2 cm) models A. 30" (76.2 cm) min. cabinet width B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door C. 4" to 12" (10.2 to 30.5 cm) bottom of cutout to floor D. 28¹⁄₂" (72.4 cm) cutout width E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door F. 50.0" (127.0 cm) min. cutout height Cabinet Side View - Double or Single Oven Electrical Requirements If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and the wire gauge are in accordance with local codes. Check with a qualified electrical installer if you are not sure the oven is properly grounded. This oven must be connected to a grounded metal, permanent wiring system. Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances. A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 Electrical Connection To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ■ Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located at the bottom of the left-hand mounting rail. See the following illustration. A B E C D A. 24" (61.0 cm) min. cutout depth B. 23½" (59.7 cm) recessed oven depth C. Oven front D. Recessed oven E. Cabinet A A Single Oven A. Model/serial number plate Double Oven A. Model/serial number plate KW Rating on Recommended Wire Size Serial/rating Plate Minimum Circuit (AWG) Protection in Amps 0.0 - 4.8 20 12 7.0 - 9.9 40 8 ■ A circuit breaker is recommended. ■ Connect directly to the circuit breaker box (or fused disconnect) through flexible, armored or nonmetallic sheathed, copper cable (with grounding wire). See "Make Electrical Connection" section. 4