Maytag MGD6000XG Dimension Guide - Page 1
Maytag MGD6000XG Manual
View all Maytag MGD6000XG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Gas Dryer PRODUCT MODEL NUMBERS MGD6000X, MGD7000X, MGD9000X, MGD9000Y Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result. Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Hood styles: A & B are recommended. A B C A. Louvered hood B. Box hood C. Angled hood (acceptable) The vent system chart provides venting requirments that will help to achieve the best drying performance. Vent system chart: NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Number of 90° elbows Vent system chart Type of vent Box/louvered hoods Angled hoods 0 Rigid metal 64 ft. (20 m) 58 ft. (17.7 m) 1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m) 2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m) 3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) OVERALL DIMENSIONS Dryer dimensions Front view: 27" (686 mm) Side view: 507/8" (1292 mm) 311/8" (790 mm) 381/8" (968 mm) 53/4"* (146 mm) 3/4"* (18 mm) Back view: 53/4"* (146 mm) Water inlet Vent 3/4"* (18 mm) 61/4" (159 mm) NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with 297/8"* (759 mm) elbow. See "Venting Requirements." 31/2"* (89 mm) Gas 3/4"* (18 mm) 143/8" (365 mm) 253/4" (654 mm) 61/8"* (156 mm) * Approximate measurement Recommended installation clearances (dryer only) 5" (127 mm) 18" min. (457 mm) 3" (76 mm) 48 in.2 min. (310 cm2) 24 in.2 min. (155 cm2) 3" (76 mm) 1" (25 mm) 1" (25 mm) For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10057364B 03/2011