Meade TE653ELW-M User Manual - Page 7

A. Weather Forecast/ Pressure, B. Temperature/ Humidity, C. Clock, D. Down, E. Alarm, F. Temp Alarm - set time zone

Page 7 highlights

A. WEATHER FORECAST/ PRESSURE window B. TEMPERATURE/ HUMIDITY window C. CLOCK window D. DOWN button • Select the next available mode • Press and hold for 2 seconds to search for wireless signal from remote sensor. • Decrease parameters. E. ALARM button • When time mode has been selected, press once to display the alarm time of weekday alarm (W), single alarm (S) and pre-alarm (Pre-AL). • Hold for 2 seconds, set weekday, single and pre-alarm's alarm time • When alarm is on, press once to stop the alarm temporarily. F. TEMP ALARM button • When temperature mode has been selected, press once to display the highest or lowest temperature alarm's value. • Hold for 2 seconds, set the highest lowest temperature alarm's value • When alarm is on, press once to stop the alarm temporarily. G. CHANNEL button • Press to display the outdoor temperature readings of Channels 1, 2 and 3. • Hold for 2 seconds, enter into the circulation mode and outdoor temperature readings of Channels 1, 2 or 3 will be displayed automatically in every 5 seconds. H. MODE button • When pressure mode has been selected, press once to display the local pressure, altitude and sea level. • Press and hold for 2 seconds to set altitude and sea level. • When time mode has been selected, press once to toggle between time with seconds display or time with weekday display. • Press and hold for 2 seconds, set language of the day of the week, year digit, month digit, date digit, hour format (12/ 24 hours), hour digit and minute digit. (Note: calendar format is default in month-date display). • When temperature mode has been selected, press and hold for 2 seconds to toggle the temperature unit between Celsius or Fahrenheit. I. UP button • Press to select the next available mode • Increase the parameters • In time with seconds display mode, press and hold for 2 seconds to activate/ deactivate radio controlled time signal search manually. • In time with weekday display mode, press and hold for 2 seconds to switch time zone from Pacific, Mountain, Central to Eastern. J. HISTORY button • When pressure mode has been selected, press once to check the historical pressure data for the past 24 hours. K. MEMORY button • When temperature mode has been selected, press to recall the minimum or maximum temperature and humidity readings of main unit and remote units. • Press and hold for 2 seconds, collected memories will be cleared. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

A. WEATHER FORECAST/ PRESSURE
window
B. TEMPERATURE/ HUMIDITY
window
C. CLOCK
window
D. DOWN
button
• Select the next available mode
• Press and hold for 2 seconds to search for wireless signal from remote sensor.
• Decrease parameters.
E. ALARM
button
• When time mode has been selected, press once to display the alarm time of weekday
alarm (W), single alarm (S) and pre-alarm (Pre-AL).
• Hold for 2 seconds, set weekday, single and pre-alarm’s alarm time
• When alarm is on, press once to stop the alarm temporarily.
F. TEMP ALARM
button
• When temperature mode has been selected, press once to display the highest or lowest
temperature alarm’s value.
• Hold for 2 seconds, set the highest lowest temperature alarm’s value
• When alarm is on, press once to stop the alarm temporarily.
G. CHANNEL
button
• Press to display the outdoor temperature readings of Channels 1, 2 and 3.
• Hold for 2 seconds, enter into the circulation mode and outdoor temperature readings of
Channels 1, 2 or
3 will be displayed automatically in every 5 seconds.
H. MODE
button
• When pressure mode has been selected, press once to display the local pressure, altitude and
sea level.
• Press and hold for 2 seconds to set altitude and sea level.
• When time mode has been selected, press once to toggle between time with seconds display or
time with weekday display.
• Press and hold for 2 seconds, set language of the day of the week, year digit, month digit, date
digit, hour format (12/ 24 hours), hour digit and minute digit. (Note: calendar format is default
in month-date display).
• When temperature mode has been selected, press and hold for 2 seconds to toggle the
temperature unit between Celsius or Fahrenheit.
I. UP
button
• Press to select the next available mode
• Increase the parameters
• In time with seconds display mode, press and hold for 2 seconds to activate/ deactivate radio
controlled time signal search manually.
• In time with weekday display mode, press and hold for 2 seconds to switch time zone from
Pacific, Mountain, Central to Eastern.
J. HISTORY
button
• When pressure mode has been selected, press once to check the historical pressure data for
the past 24 hours.
K. MEMORY
button
• When temperature mode has been selected, press to recall the minimum or maximum
temperature and humidity readings of main unit and remote units.
• Press and hold for 2 seconds, collected memories will be cleared.
7