Cooking process, Turning off, From the intensive setting IS, the fan
View all Miele DA6690 W brws manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Operation (Automatic mode) Cooking process If, for example, you switch on a burner at the highest power setting to heat cookware in preparation for searing and then reduce the power level after approx. 60 to 90 seconds*, a cooking process is recognized. The hood turns on automatically and, after the cooktop power level has been reduced, switches back to fan level 3, where it remains for approx. 5 minutes. After this, the fan level is once again determined by the Con@ctivity function. You can also manually select a different fan level before then. Turning off Turn off all burners. Over the next few minutes, the ventilation hood fan setting will decrease one level at a time until the hood eventually turns off. This helps to neutralize any lingering vapors and odors in the air. - From the intensive setting IS, the fan immediately switches to level 3. - If the fan is operating at level 3, it will switch to level 2 after approx. 1 minute. - From level 2, the fan switches to level 1 after 2 minutes. - After 2 minutes at level 1, the fan automatically turns off. - After another 30 seconds, the lighting turns off. The cooking process is now finished. 19