Miele DGC 4084 XL ss Product Manual - Page 60
amount of steam, escapes or steam
View all Miele DGC 4084 XL ss manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Frequently asked questions Problem Possible fault Solution The fan can still be heard after the appliance has been turned off. The appliance is equipped The fan automatically turns with a fan that directs off after some time. vapors from the oven interior to the outside. The fan will continue to run for a while after the appliance has been turned off. You can hear a noise Water is being pumped in (humming) when the or out. appliance is turned on, when it is operating, and after it has been turned off. This noise does not indicate a malfunction or a defect. This happens when water is pumped in and out. After moving to a new location the appliance no longer switches from the heating up phase to the cooking phase. The boiling point of water has changed because the new installation location differs by at least 984 ft. (300 m) in altitude from the old. To do this, descale the appliance (see "Cleaning and care - Descale"). During operation an unusually large amount of steam escapes or steam escapes from parts of the steam oven where it does not usually. The door is not properly closed. Close the door. The door gasket is not seated properly. Press the door gasket all the way around the door to make sure it is fitted evenly. The door seal is damaged, Replace the gasket. e.g. cracks. The control panel Something is obstructing Remove the obstruction. does not open/close the panel. automatically despite The finger pinch protection Open/close the panel repeatedly pressing is very sensitive, so it may manually (see "Frequently the "Lift Panel" button. happen occasionally that asked questions - Manually the control panel does not opening the control panel). open or close. If the problem occurs very frequently, contact Miele Technical Service. 60