Connection to the drainage system, Connecting the drain hose, siphon with a fixed hose connection
View all Miele DGC 6805-1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
Water connection Connection to the drainage system WARNING - Read all instructions before installation or use of the steam oven to prevent injury and machine damage. Connecting the drain hose Connect the plastic hose to the siphon using the hose sleeve Ø 3/4" (21 mm). Then secure the hose with the hose clamp. The drainage trap must not be located higher than the drain hose connection point on the appliance. This is to ensure that water can drain out completely after a program. The top end of the drain hose must not be higher than 19 11/16" (500 mm) where it connects to the siphon. The plastic drain hose supplied must not be shortened. The drain can be connected to either - a surface mounted or flush-mounted siphon with a fixed hose connection or - to the appliance's rinsing siphon connection. The temperature of the drainage water is approx. 160°F / 70°C. Only genuine original Miele hoses can be used with this appliance. 181